Add Siemens S7 Controller (TIA Portal) dialog box
How do I open the Add Siemens S7 Controller (TIA Portal) dialog box?
- If you are not already in Design mode, click
. - In the Asset Catalog, expand theController Itemsnode.
- Drag a Siemens S7 Controller (TIA Portal) asset onto the tree in the Asset View.
Use the
Add Siemens S7 Controller (TIA Portal)
dialog box to add a Siemens S7 Controller (TIA Portal) to the asset tree. You can add an S7 Controller (TIA Portal) in the root or in a container.The device is added to the asset tree as soon as this dialog box opens. Clicking
Cancel
in this dialog box abandons any changes made to the device properties, but leaves the device in the tree.
IMPORTANT:
- Make sure you have installed the Siemens S7 Controller (TIA Portal) with TIA Openness on the FactoryTalk AssetCentre agent computer.
- If you install the Siemens S7 Controller (TIA Portal) after installing the FactoryTalk AssetCentre Agent, you should run the FactoryTalk AssetCentre Agent Controller Launch Control Panel fromStart>Rockwell Software, and then selectRepair.
- Make sure that the FactoryTalk AssetCentre Agent Controller is running as an application. For more information, see FactoryTalk AssetCentre Agent Controller Launch Control Panel.
- Make sure to select a standard Windows domain user account if you are in a Windows domain environment and the FactoryTalk AssetCentre AgentController runs as an application. This allows Microsoft Windows Communication Foundation (WCF) to authenticate between the FactoryTalk AssetCentre agent to connect to the FactoryTalk AssetCentre server. If the AgentController is configured to use a local Windows user account, then WCF won’t work correctly and the FactoryTalk AssetCentre agent won’t be able to connect to the server.
- Make sure you have disabled the FIPS.
- If your access level for the PLC isNo access (complete protection)orHMI access, use the passwords that are set forFull access (no protection)orRead accessto access.