Siemens S5 Controller operation properties for disaster recovery
Following are all possible settings for disaster recovery schedules for Siemens S5
Controller assets.
These settings are used for two purposes:
- Specify default disaster recovery schedule settings for Siemens S5 Controllers inTools>Options.
- Specify the settings of a particular Siemens S5 Controller asset in an existing schedule on theSchedulestab. Changes to the settings within a schedule override the default settings for that instance.
Unless noted otherwise, each setting applies to backup schedules and backup and compare schedules.
(Backup and compare schedules only) Event Settings
- Backup Compare PartnerSpecify the version of the backup data binder to compare to the controller files.
- Configuration Data Compare PartnerFor Siemens S5 devices, the configuration data is not compared during a backup and compare operation unless specified. Specify the version of the configuration data binder to compare to the device files.
- Create New Backup VersionSet toAlwaysto create a backup version even if it is exactly the same as the last compared backup version. This is the default setting.Set toOn Differences Foundto create a backup version only if differences are found. If the existing backup is the same as the information in the controller aside from excluded data blocks, then no backup is saved.
Asset-specific properties
- Block OptionsWhen you set up the binder for the Siemens S5 Controller you had the opportunity to exclude files that you did not want included in the binder. Here you can exclude blocks of the Siemens S5 project that you do not want included in a backup or a backup and compare operation.Click in theBlock Optionsfield and then click
. Fill in the Block Optionsdialog box. - Compare Data Blocks (and Extended Data Blocks) by Length (Backup and compare schedules only)This option applies only to excluded blocks.Set toTrueto look for changes to the length of excluded data blocks but not the data values. This comparison ensures that important changes to the length of blocks, such as adding or deleting a value, are detected for data blocks that are excluded from the compare. It also detects if a whole data block is added or removed.Set toFalseto compare neither length nor structure (values) for excluded blocks. No changes to excluded blocks will be detected.
Email notification
You can type email recipients' addresses separated by semicolons (;) or select addresses from the FactoryTalk AssetCentre Address Book. To select addresses from the Address Book, click in the field, and then click
. Complete the
. Complete the Contacts and Groups
dialog box.An email message will be sent to only one of these lists. For example, if differences are found when a backup and compare schedule runs, an email is sent to those on the
Event Compare Differences Detected
list. No email is sent to those on the Event Completed
list.- (Backup and compare schedules only) Event Compare Differences DetectedThe email addresses, separated by semicolons (;), to which notification will be sent if the compare finds differences between the specified backup data or configuration data version and the data on the physical device.
- Event CompletedThe email addresses, separated by semicolons (;), to which notification will be sent when the operation completes for the asset. If a backup and compare schedule completes without differences, an email is sent to this list. If it completes with differences, an email is sent to theEvent Compare Differences Detectedlist, not this list.
- Event FailedThe email addresses, separated by semicolons (;), to which notification will be sent if the operation fails.
(Backup and compare schedules only) Attach report to email
- Event Completed Differences DetectedThis defaults toTrueto attach a report of differences to the email if the backup and compare schedule finds differences between the specified backup data or configuration data version and the data on the physical device. SelectFalseto send an email without an attached report.