Set binder key file for Siemens S7 Controllers (STEP7) to use file associations
Use the
Options: File Associations
dialog box to have a designated software
product open file with a specific extension. For Siemens S7 Controllers (STEP7),
FactoryTalk AssetCentre uses a binder to store configuration files. When using file
associations for a Siemens S7 program file, a key filemust be set correctly for the
binder so that the software program associated with that file type can open that key
file for the binder.For Siemens S7 program files, FactoryTalkAssetCentre includes a tool thatfinds and opens
the editing software for S7P files. This tool comesset up in the
File
Associations
dialog box, so there is no need to set file associations for these
file types.For other type of program files to use file associations, you also need to make sure that
a key file is set correctly for the binder. Associating a file type with a program must
also be set in
Tools
> Options
> File Associations
. For more
information, see Set file associations and Options dialog box: File Associations.To set a key file for a new binder
- If you are not in Design mode, select
. - Drag a Siemens S7 Controllers (STEP7) asset from the Asset Catalog to add it to the Asset View or double-click a Siemens S7 Controllers (STEP7) asset in the asset tree.
- Select anywhere within theConfiguration Datafield, and then select
. - In the left pane of theConfiguration Data Browserdialog box, select the Siemens S7 Controllers (STEP7) asset, and then selectAdd.
- OnAdd Binder:
- Enter theNameandDescriptionfields as needed.
- SelectBrowseto specify a source folder, and then selectOK.
- find the S7P file, and then selectExpand the specified folder in theContentsection,Setto set that file as a key file.
- SelectOK.
- In the right pane of theConfiguration Data Browserdialog box, select the new binder.
- Select the S7 program to use for disaster recovery operations. More than one S7 program may be included in the binder. However, only one S7 project can be included in the binder. You cannot select a program if more than one project is in the binder.
- Select theProgram Refreshbutton if it is available to update the binder with any program changes.
- In theProgramlist, select the S7 program.
- SelectOK.
- Edit other properties as needed, and then selectOK.
- (optional) Open the binder to get a local copy of the key file or check it out for editing.
- In the asset tree, right-click the binder, and then selectOpen.
- SelectView > Archive, and then select the binder in the asset tree. At the top of the Archive tab, select the filename link.
To set a key file for an existing binder
- If you are not in Design mode, select
. - Expand the Siemens S7 Controllers (STEP7) asset in the asset tree, and then select the binder that you want to edit.
- Right-click the binder, and then selectCheck Out.
- OnCheck Out, keep the default settings and enter the comments, and then selectOK.
- Double-click binder to open binder properties.
- find the S7P file, and then selectExpand the specified folder in theContentsection,Setto set that file as a key file.TIP:Make sure that the S7P file is stored in the specified location.
- SelectOK.
- (optional) Open the binder to get a local copy of the key file or check it out for editing.
- In the asset tree, right-click the binder, and then selectOpen.
- SelectView > Archiveand select the binder in the asset tree. At the top of the Archive tab, select the filename link.