Service dependencies of Rockwell Automation software

The table below shows the service dependencies in Rockwell Automation software.
TIP:
  • Tip: If you are running on a 64-bit operating system, the files are under the
    \Program Files (x86)
    directory, not
    \Program Files
    .
  • C:\Program Files
    is the default installation directory for Rockwell Automation. If you have installed Rockwell Automation on another drive location, replace
    C:\
    with your specific drive letter.
Service name
The service is located in
Dependent service name
The dependent service is located in
dnwhodisp
C:\Program Files\Rockwell Software\RSLinx\dnwhodisp.exe
Microsoft Remote Procedure Call (RPC)
N/A
FactoryTalk AssetCentre AgentController
C:\Program Files\Rockwell Software\AssetCentre Agents\AgentController\RA.FTAC.AgentControllerService.exe
Rockwell Directory Multiplexer
C:\Program Files\Common Files\Rockwell\RNADirMultiplexor.exe
FactoryTalk AssetCentre Inventory Crawler Server
C:\Program Files\Rockwell Software\AssetCentre Inventory Crawler\RA.FTAC.InventoryCrawler.Server.exe
RSLinx Classic
C:\Program Files\Rockwell Software\RSLinx\RSLinx.exe
FactoryTalk AssetCentre Server
C:\Program Files\Rockwell Software\AssetCentre Server\Bin\RA.FTAC.Server.exe
Rockwell Directory Multiplexer
C:\Program Files\Common Files\Rockwell\RNADirMultiplexor.exe
FactoryTalk Diagnostics Local Reader
C:\Program Files\CommonFiles\Rockwell\RNADiagnosticsSrv.exe
(No dependency)
N/A
FTSysDiagSvcHost
C:\Program Files\CommonFiles\Rockwell\FTSysDiagSvcHost.exe
Microsoft Remote Procedure Call (RPC)
N/A
Harmony
C:\Program Files\Rockwell Software\RSCommon\RSOBSERV.EXE
Microsoft Remote Procedure Call (RPC)
N/A
LogReceiver
C:\Program Files\Rockwell Software\RSLinx Enterprise\LogReceiver.exe
(No dependency)
N/A
OpcEnum
C:\Windows\System32\OpcEnum.exe (for 32-bit operating systems)
C:\Windows\SysWOW64\OpcEnum.exe (for 64-bit operating systems)
Microsoft Remote Procedure Call (RPC)
N/A
Rockwell Application Services
C:\Program Files\CommonFiles\Rockwell\RsvcHost.exe
Microsoft Remote Procedure Call (RPC)
N/A
Rockwell Directory Multiplexer
C:\Program Files\CommonFiles\Rockwell\RNADirMultiplexor.exe
Microsoft Remote Procedure Call (RPC)
N/A
Rockwell Event Multiplexer
C:\Program Files\CommonFiles\Rockwell\EventClientMultiplexer.exe
Rockwell Directory Server
C:\Program Files\CommonFiles\Rockwell\RnaDirServer.exe
Microsoft Remote Procedure Call (RPC)
N/A
Rockwell Event Multiplexer
C:\Program Files\CommonFiles\Rockwell\EventClientMultiplexer.exe
Rockwell Event Multiplexer
C:\Program Files\CommonFiles\Rockwell\EventClientMultiplexer.exe
Microsoft Remote Procedure Call (RPC)
N/A
Rockwell Application Services
C:\Program Files\CommonFiles\Rockwell\RsvcHost.exe
Rockwell Redundancy Services
C:\Program Files\CommonFiles\Rockwell\RdcyHost.exe
Rockwell Event Server
C:\Program Files\CommonFiles\Rockwell\EventServer.exe
Microsoft Remote Procedure Call (RPC)
N/A
Rockwell Namespace Services
C:\Program Files\CommonFiles\Rockwell\NmspHost.exe
Microsoft Remote Procedure Call (RPC)
N/A
Rockwell Redundancy Services
C:\Program Files\CommonFiles\Rockwell\RdcyHost.exe
Microsoft Remote Procedure Call (RPC)
N/A
RSLinx Classic
C:\Program Files\Rockwell Software\RSLinx\RSLinx.exe
Harmony
C:\Program Files\Rockwell Software\RSCommon\RSOBSERV.EXE
FactoryTalk Linx
C:\Program Files\Rockwell Software\RSLinx Enterprise\RSLinxNG.exe
Microsoft Remote Procedure Call (RPC)
N/A
VerificationAgent
C:\Program Files\Rockwell Software\AssetCentre RA Disaster Recovery Agent\VerificationAgent.exe
RSLinx Classic
C:\Program Files\Rockwell Software \RSLinx\RSLINX.EXE