512-DAB-6P
NEMA Combination Starter Disconnect
Serial #:
This product has not been verified. Please register your product to confirm authenticity.
Lifecycle status:
Active
Lifecycle status:
Active
Description
Available from RCC, NEMA Combination Starter, Disconnect Type, NEMA 3, 480 Volts (B), Type 1 - Enclosure Code "A"
Overview
Technical Specifications
General
Electrical
Contruction
Mechanical
Construction
Environmental
Documents
Accessories
Alternative Products
Technotes
| Unique Product Identifier |
512-DAB-6P
|
|---|---|
| UPC |
662072536384
|
| Estimated Lead Time |
56 days
|
| Country of Origin |
>1
|
| Fuse Clips |
No Fuse Clip
|
|---|
| Voltage type for actuating |
AC
|
|---|---|
| With transformer |
True
|
| Suitable for emergency stop |
True
|
| External reset possible |
True
|
| With short-circuit release |
False
|
| With fuse |
False
|
| Rated control supply voltage at AC 50 Hz |
110 V
|
| Rated control supply voltage at AC 60 Hz |
120 V
|
| Type of motor starter |
Direct online starter (DOL)
|
| Continuous current |
90 A
|
| Circuit closing inrush current peak including offset, max |
947 A
|
| Load voltage |
460V
|
| Fuse clips |
No fuse clips
|
| Heat dissipation |
10 W (2...3 poles)
|
| Coil operating limits |
85...110%
|
| Operating volt amperes burden |
Sealed: 45VA, 60 Hz coils (2...3 poles)
|
| Hp rating |
50 Hp
|
| Factory installed models |
Transformer with 2 primary & 1 sary fuse
|
| Temperature compensated overload protection |
True
|
| Coordination class according to IEC 60947-4-3 |
Class 2
|
| Type of electrical connection of main circuit |
Screw connection
|
| Type of electrical connection for auxiliary- and control current circuit |
Screw connection
|
| Width |
20.5 mm
|
|---|---|
| Height |
30 mm
|
| Depth |
9.88 mm
|
| Degree of protection (NEMA) |
1
|
|---|---|
| Number of auxiliary contacts, max |
8
|
| Weight |
90 lb
|
| Mechanical life operations |
5000000
|
| Operating time, drop-out |
20 ms
|
| Operating time, pick-up |
37 ms
|
| Material housing |
Steel
|
| Enclosure type |
NEMA 1 general purpose
|
| Required torque on power terminal wire clamps and pressure connectors or lugs |
150 in-lb
|
|---|---|
| Auxiliary contact material |
Silver
|
| Type of power terminal |
Pressure terminals
|
| Wire size |
For power terminals: 8...1 AWG
|
| Power contact material |
Silver Alloy
|
| NEMA size |
Size 3
|
|---|---|
| Operating temperature |
-25 °C
|
| Operating position |
Vertical
|
| Altitude |
10000 ft before derating
|
| Overload relay |
Eutectic Alloy overload relay
|
| Corrosion-resistance |
All metal parts are treated for corrosion-resistance
|
| General | Publication |
|---|---|
| Product Cutsheet | -- |
| Technical Data | Publication |
|---|---|
| 500-td014_-en-p | 500-TD014 |
| 500-td014_-en-p | 500-TD014 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Items Per Page:
Items Per Page:
| Technotes |
|---|
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Overview
| Unique Product Identifier |
512-DAB-6P
|
|---|---|
| UPC |
662072536384
|
| Estimated Lead Time |
56 days
|
| Country of Origin |
>1
|
Technical Specifications
| Fuse Clips |
No Fuse Clip
|
|---|
| Voltage type for actuating |
AC
|
|---|---|
| With transformer |
True
|
| Suitable for emergency stop |
True
|
| External reset possible |
True
|
| With short-circuit release |
False
|
| With fuse |
False
|
| Rated control supply voltage at AC 50 Hz |
110 V
|
| Rated control supply voltage at AC 60 Hz |
120 V
|
| Type of motor starter |
Direct online starter (DOL)
|
| Continuous current |
90 A
|
| Circuit closing inrush current peak including offset, max |
947 A
|
| Load voltage |
460V
|
| Fuse clips |
No fuse clips
|
| Heat dissipation |
10 W (2...3 poles)
|
| Coil operating limits |
85...110%
|
| Operating volt amperes burden |
Sealed: 45VA, 60 Hz coils (2...3 poles)
|
| Hp rating |
50 Hp
|
| Factory installed models |
Transformer with 2 primary & 1 sary fuse
|
| Temperature compensated overload protection |
True
|
| Coordination class according to IEC 60947-4-3 |
Class 2
|
| Type of electrical connection of main circuit |
Screw connection
|
| Type of electrical connection for auxiliary- and control current circuit |
Screw connection
|
| Width |
20.5 mm
|
|---|---|
| Height |
30 mm
|
| Depth |
9.88 mm
|
| Degree of protection (NEMA) |
1
|
|---|---|
| Number of auxiliary contacts, max |
8
|
| Weight |
90 lb
|
| Mechanical life operations |
5000000
|
| Operating time, drop-out |
20 ms
|
| Operating time, pick-up |
37 ms
|
| Material housing |
Steel
|
| Enclosure type |
NEMA 1 general purpose
|
| Required torque on power terminal wire clamps and pressure connectors or lugs |
150 in-lb
|
|---|---|
| Auxiliary contact material |
Silver
|
| Type of power terminal |
Pressure terminals
|
| Wire size |
For power terminals: 8...1 AWG
|
| Power contact material |
Silver Alloy
|
| NEMA size |
Size 3
|
|---|---|
| Operating temperature |
-25 °C
|
| Operating position |
Vertical
|
| Altitude |
10000 ft before derating
|
| Overload relay |
Eutectic Alloy overload relay
|
| Corrosion-resistance |
All metal parts are treated for corrosion-resistance
|
Documents
|
Product Cutsheet
General
-- |
|
500-td014_-en-p
Technical Data
500-TD014 |
|
500-td014_-en-p
Technical Data
500-TD014 |
| General | Publication |
|---|---|
| Product Cutsheet | -- |
| Technical Data | Publication |
| 500-td014_-en-p | 500-TD014 |
| 500-td014_-en-p | 500-TD014 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Accessories
Items Per Page:
Alternative Products
Items Per Page:
Technotes
| Technotes |
|---|
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
NEMA Combination Starter Disconnect
512-DAB-6P
Close
Print
Copyright ©2026 Rockwell Automation, Inc.