Technical Specifications
Electrical
Contruction
Mechanical
Construction
Environmental
Documents
Accessories
Alternative Products
Technotes
| Voltage type for actuating |
AC
|
|---|---|
| With transformer |
True
|
| Suitable for emergency stop |
True
|
| External reset possible |
True
|
| With short-circuit release |
True
|
| With fuse |
True
|
| Rated control supply voltage at AC 50 Hz |
110 V
|
| Rated control supply voltage at AC 60 Hz |
120 V
|
| Type of motor starter |
Direct online starter (DOL)
|
| Continuous current |
45 A
|
| Circuit closing inrush current peak including offset, max |
483 A
|
| Available short circuit amperes RMS symmetrical |
100000 A
|
| Load voltage |
230V
|
| Fuse clips |
60 A Class R
|
| Heat dissipation |
5.9 W (2...3 poles)
|
| Coil operating limits |
85...110%
|
| Operating volt amperes burden |
Sealed: 29VA, 60 Hz coils (2...3 poles)
|
| Hp rating |
15 Hp
|
| Factory installed models |
Transformer with 2 primary & 1 sary fuse
|
| Temperature compensated overload protection |
True
|
| Coordination class according to IEC 60947-4-3 |
Class 2
|
| Type of electrical connection of main circuit |
Screw connection
|
| Type of electrical connection for auxiliary- and control current circuit |
Screw connection
|
| Width |
10.5 mm
|
|---|---|
| Height |
27.5 mm
|
| Depth |
8.25 mm
|
| Degree of protection (NEMA) |
12
|
|---|---|
| Number of auxiliary contacts, max |
8
|
| Weight |
40 lb
|
| Mechanical life operations |
1.0E7
|
| Operating time, drop-out |
13 ms
|
| Operating time, pick-up |
27 ms
|
| Material housing |
Steel
|
| Enclosure type |
NEMA 3R/4/12 non-metal handle
|
| Required torque on power terminal wire clamps and pressure connectors or lugs |
45 in-lb
|
|---|---|
| Auxiliary contact material |
Silver
|
| Type of power terminal |
Pressure terminals
|
| Wire size |
For power terminals: 14...4 AWG
|
| Power contact material |
Silver Alloy
|
| NEMA size |
Size 2
|
|---|---|
| Operating temperature |
-25 °C
|
| Operating position |
Vertical
|
| Altitude |
10000 ft before derating
|
| Overload relay |
Eutectic alloy overload relay
|
| Corrosion-resistance |
All metal parts are treated for corrosion-resistance
|
| General | Publication |
|---|---|
| Product Cutsheet | -- |
| Technical Data | Publication |
|---|---|
| 500-td014_-en-p | 500-TD014 |
| 500-td014_-en-p | 500-TD014 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center
Search the Literature Library
Items Per Page:
Items Per Page:
| Technotes |
|---|
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
| Voltage type for actuating |
AC
|
|---|---|
| With transformer |
True
|
| Suitable for emergency stop |
True
|
| External reset possible |
True
|
| With short-circuit release |
True
|
| With fuse |
True
|
| Rated control supply voltage at AC 50 Hz |
110 V
|
| Rated control supply voltage at AC 60 Hz |
120 V
|
| Type of motor starter |
Direct online starter (DOL)
|
| Continuous current |
45 A
|
| Circuit closing inrush current peak including offset, max |
483 A
|
| Available short circuit amperes RMS symmetrical |
100000 A
|
| Load voltage |
230V
|
| Fuse clips |
60 A Class R
|
| Heat dissipation |
5.9 W (2...3 poles)
|
| Coil operating limits |
85...110%
|
| Operating volt amperes burden |
Sealed: 29VA, 60 Hz coils (2...3 poles)
|
| Hp rating |
15 Hp
|
| Factory installed models |
Transformer with 2 primary & 1 sary fuse
|
| Temperature compensated overload protection |
True
|
| Coordination class according to IEC 60947-4-3 |
Class 2
|
| Type of electrical connection of main circuit |
Screw connection
|
| Type of electrical connection for auxiliary- and control current circuit |
Screw connection
|
| Width |
10.5 mm
|
|---|---|
| Height |
27.5 mm
|
| Depth |
8.25 mm
|
| Degree of protection (NEMA) |
12
|
|---|---|
| Number of auxiliary contacts, max |
8
|
| Weight |
40 lb
|
| Mechanical life operations |
1.0E7
|
| Operating time, drop-out |
13 ms
|
| Operating time, pick-up |
27 ms
|
| Material housing |
Steel
|
| Enclosure type |
NEMA 3R/4/12 non-metal handle
|
| Required torque on power terminal wire clamps and pressure connectors or lugs |
45 in-lb
|
|---|---|
| Auxiliary contact material |
Silver
|
| Type of power terminal |
Pressure terminals
|
| Wire size |
For power terminals: 14...4 AWG
|
| Power contact material |
Silver Alloy
|
| NEMA size |
Size 2
|
|---|---|
| Operating temperature |
-25 °C
|
| Operating position |
Vertical
|
| Altitude |
10000 ft before derating
|
| Overload relay |
Eutectic alloy overload relay
|
| Corrosion-resistance |
All metal parts are treated for corrosion-resistance
|
Documents
|
Product Cutsheet
General
-- |
|
500-td014_-en-p
Technical Data
500-TD014 |
|
500-td014_-en-p
Technical Data
500-TD014 |
| General | Publication |
|---|---|
| Product Cutsheet | -- |
| Technical Data | Publication |
| 500-td014_-en-p | 500-TD014 |
| 500-td014_-en-p | 500-TD014 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center
Search the Literature Library
Accessories
Items Per Page:
Alternative Products
Items Per Page:
Technotes
| Technotes |
|---|
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
NEMA Combination Starter Disconnect
512-CFA-1-6P-25R
Close
Print
Copyright ©2026 Rockwell Automation, Inc.