NEMA 3 Phase Non-Reversing Starter
| Unique Product Identifier |
509-BOD-A2F-901
|
|---|---|
| UPC |
612598888689
|
| Estimated Lead Time |
21 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Mexico
|
| EU Importer Address |
Rockwell Automation N.V |
| EU Authorized Representative Address |
Rockwell Automation N.V |
The information provided by Rockwell Automation on www.rockwellautomation.com (the “Site”) is for demonstration purposes only and may be incomplete or inaccurate. All information is provided “as is”, and Rockwell Automation makes no representations or warranties of any kind, express or implied, regarding the accuracy, adequacy, validity, reliability, or completeness of any information on the Site. Use of this information is at your own risk.
| Number of auxiliary contacts as normally open contact |
1
|
|---|---|
| Number of auxiliary contacts as normally closed contact |
1
|
| Number of indicator lights |
0
|
| Voltage type for actuating |
AC
|
| With transformer |
False
|
| Suitable for emergency stop |
True
|
| Supporting protocol for PROFIBUS |
False
|
| External reset possible |
True
|
| With short-circuit release |
True
|
| With fuse |
False
|
| Supporting protocol for EtherNet/IP |
False
|
| Rated control supply voltage at AC 50 Hz |
110 V
|
| Rated control supply voltage at AC 60 Hz |
120 V
|
| Release class |
Adjustable
|
| Overload release current setting |
3.2 A
|
| Type of motor starter |
Direct online starter (DOL)
|
| Service limit current rating |
32 A
|
| Continuous current |
27 A
|
| Circuit closing inrush current peak including offset, max |
288 A
|
| Heat dissipation |
5.9 W
|
| Coil operating limits |
85...110%
|
| Operating volt amperes burden |
Sealed: 29VA, 60 Hz coils
|
| Hp rating, max |
7.5Hp @ 230V load voltage, 3-phase (non-plugging and non-jogging duty)
|
| Transformer primary switching kVA rating |
8.5 kVA @ 460V load voltage, 3-phase (inrush current ≤20 times continuous current)
|
| Capacitor switching kVAR |
6 kVAR @ 230V, 3-phase (If maximum available current (at capacitor terminals) is greater than 3000 A, contact your local Rockwell Automation sales office, Allen-Bradley distributor, or NEMA ICS-2 standard)
|
| Factory installed models |
1 NO & 1 NC auxiliary contact on the contactor
|
| Supporting protocol for DeviceNet |
True
|
| Temperature compensated overload protection |
True
|
| Coordination class according to IEC 60947-4-3 |
Class 2
|
| Type of electrical connection of main circuit |
Screw connection
|
| Type of electrical connection for auxiliary- and control current circuit |
Screw connection
|
| Rail mounting possible |
True
|
|---|---|
| Number of auxiliary contacts, max |
8
|
| Mechanical life operations |
1.0E7
|
| Average operating time, pick-up |
22 ms
|
| Average operating time, drop-out |
14 ms
|
| Required torque on power terminal wire clamps and pressure connectors or lugs |
20 in-lb
|
|---|---|
| Auxiliary contact material |
Silver
|
| Type of power terminal |
Saddle or wire clA
|
| Wire size |
For power terminals: 14...8 AWG
|
| Enclosure |
Open type
|
| Power contact material |
Silver Alloy
|
| Requirements for sizing of wire |
All wire rated 167 °F (75 °C) or higher must be sized per the local electrical code for 167 °F (75 °C) wire
|
| NEMA size |
Size 1
|
|---|---|
| Operating temperature |
55 °C
|
| Operating position |
Vertical
|
| Altitude |
10000 ft before derating
|
| Overload relay |
Overload relay, full load current adjustment range 3.2...16 A
|
| Corrosion-resistance |
All metal parts are treated for corrosion-resistance
|
| Drawings | |
|---|---|
| 3D STEP Model (STP) | Download (ZIP) |
| 2D Drawing (PDF) | Download (PDF) |
| Product Drawing | Drawing (DWG) |
| Product Drawing | Drawing (DXF) |
| Drawings |
|---|
| 3D STEP Model (STP) Download (ZIP) |
| 2D Drawing (PDF) Download (PDF) |
| Product Drawing Drawing (DWG) |
| Product Drawing Drawing (DXF) |
| General | Publication |
|---|---|
| Circuit Protection Design and SCCR Tables | -- |
| Repair Parts List | -- |
| Product Cutsheet | -- |
| Technical Data | Publication |
|---|---|
| 500-td014_-en-p | 500-TD014 |
| Technotes |
|---|
Overview
| Unique Product Identifier |
509-BOD-A2F-901
|
|---|---|
| UPC |
612598888689
|
| Estimated Lead Time |
21 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Mexico
|
| EU Importer Address |
Rockwell Automation N.V |
| EU Authorized Representative Address |
Rockwell Automation N.V |
The information provided by Rockwell Automation on www.rockwellautomation.com (the “Site”) is for demonstration purposes only and may be incomplete or inaccurate. All information is provided “as is”, and Rockwell Automation makes no representations or warranties of any kind, express or implied, regarding the accuracy, adequacy, validity, reliability, or completeness of any information on the Site. Use of this information is at your own risk.
Technical Specifications
| Number of auxiliary contacts as normally open contact |
1
|
|---|---|
| Number of auxiliary contacts as normally closed contact |
1
|
| Number of indicator lights |
0
|
| Voltage type for actuating |
AC
|
| With transformer |
False
|
| Suitable for emergency stop |
True
|
| Supporting protocol for PROFIBUS |
False
|
| External reset possible |
True
|
| With short-circuit release |
True
|
| With fuse |
False
|
| Supporting protocol for EtherNet/IP |
False
|
| Rated control supply voltage at AC 50 Hz |
110 V
|
| Rated control supply voltage at AC 60 Hz |
120 V
|
| Release class |
Adjustable
|
| Overload release current setting |
3.2 A
|
| Type of motor starter |
Direct online starter (DOL)
|
| Service limit current rating |
32 A
|
| Continuous current |
27 A
|
| Circuit closing inrush current peak including offset, max |
288 A
|
| Heat dissipation |
5.9 W
|
| Coil operating limits |
85...110%
|
| Operating volt amperes burden |
Sealed: 29VA, 60 Hz coils
|
| Hp rating, max |
7.5Hp @ 230V load voltage, 3-phase (non-plugging and non-jogging duty)
|
| Transformer primary switching kVA rating |
8.5 kVA @ 460V load voltage, 3-phase (inrush current ≤20 times continuous current)
|
| Capacitor switching kVAR |
6 kVAR @ 230V, 3-phase (If maximum available current (at capacitor terminals) is greater than 3000 A, contact your local Rockwell Automation sales office, Allen-Bradley distributor, or NEMA ICS-2 standard)
|
| Factory installed models |
1 NO & 1 NC auxiliary contact on the contactor
|
| Supporting protocol for DeviceNet |
True
|
| Temperature compensated overload protection |
True
|
| Coordination class according to IEC 60947-4-3 |
Class 2
|
| Type of electrical connection of main circuit |
Screw connection
|
| Type of electrical connection for auxiliary- and control current circuit |
Screw connection
|
| Rail mounting possible |
True
|
|---|---|
| Number of auxiliary contacts, max |
8
|
| Mechanical life operations |
1.0E7
|
| Average operating time, pick-up |
22 ms
|
| Average operating time, drop-out |
14 ms
|
| Required torque on power terminal wire clamps and pressure connectors or lugs |
20 in-lb
|
|---|---|
| Auxiliary contact material |
Silver
|
| Type of power terminal |
Saddle or wire clA
|
| Wire size |
For power terminals: 14...8 AWG
|
| Enclosure |
Open type
|
| Power contact material |
Silver Alloy
|
| Requirements for sizing of wire |
All wire rated 167 °F (75 °C) or higher must be sized per the local electrical code for 167 °F (75 °C) wire
|
| NEMA size |
Size 1
|
|---|---|
| Operating temperature |
55 °C
|
| Operating position |
Vertical
|
| Altitude |
10000 ft before derating
|
| Overload relay |
Overload relay, full load current adjustment range 3.2...16 A
|
| Corrosion-resistance |
All metal parts are treated for corrosion-resistance
|
Drawings
| Drawings | |
|---|---|
| 3D STEP Model (STP) | Download (ZIP) |
| 2D Drawing (PDF) | Download (PDF) |
| Product Drawing | Drawing (DWG) |
| Product Drawing | Drawing (DXF) |
| Drawings |
|---|
| 3D STEP Model (STP) Download (ZIP) |
| 2D Drawing (PDF) Download (PDF) |
| Product Drawing Drawing (DWG) |
| Product Drawing Drawing (DXF) |
Documents
|
Circuit Protection Design and SCCR Tables
General
-- |
|
Repair Parts List
General
-- |
|
Product Cutsheet
General
-- |
|
500-td014_-en-p
Technical Data
500-TD014 |
| General | Publication |
|---|---|
| Circuit Protection Design and SCCR Tables | -- |
| Repair Parts List | -- |
| Product Cutsheet | -- |
| Technical Data | Publication |
| 500-td014_-en-p | 500-TD014 |
Alternative Products
Technotes
| Technotes |
|---|