GSR Delayed Output Expansion Module
| Unique Product Identifier |
440R-EM4R2D
|
|---|---|
| UPC |
885630181691
|
| Estimated Lead Time |
5 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Multiple
|
The information provided by Rockwell Automation on www.rockwellautomation.com (the “Site”) is for demonstration purposes only and may be incomplete or inaccurate. All information is provided “as is”, and Rockwell Automation makes no representations or warranties of any kind, express or implied, regarding the accuracy, adequacy, validity, reliability, or completeness of any information on the Site. Use of this information is at your own risk.
| Output |
4 Normally Open Delayed
|
|---|
| Number of outputs, safety related, undelayed, with contact |
0
|
|---|---|
| Number of outputs, safety related, delayed, with contact |
4
|
| Number of outputs, signalling function, undelayed, with contact |
0
|
| Number of outputs, safety related, undelayed, semiconductors |
0
|
| Number of outputs, safety related, delayed, semiconductors |
0
|
| Number of outputs, signalling function, undelayed, semiconductors |
0
|
| Number of outputs, signalling function, delayed, semiconductors |
0
|
| With start input |
False
|
| With muting function |
False
|
| Voltage type for actuating |
DC
|
| Rated control supply voltage at DC |
24 V
|
| Model |
Expansion device
|
| Type of electric connection |
Screw connection
|
| Evaluation inputs |
Other
|
| Power consumption |
3.5 W
|
| Continuous safety output current |
2A @ 24V DC (0.1 Hz), DC-13 (UL: B300)
|
| Wire size |
0.2 to 2.5 mm²
|
| Number of outputs, signalling function, delayed, with contact |
0
|
| With feedback circuit |
True
|
| Surge auxillary output current duration, max |
5 ms
|
| Aggregate current of outputs per module, max |
6 A
|
| Continuous auxiliary output current |
50 mA
|
| Surge auxiliary output current |
700 mA
|
| Other input |
SWS input
|
| Other output |
SWS output
|
| Operating voltage |
20.4 V
|
| Safe failure fraction |
99 %
|
|---|---|
| Operating temperature |
-5 °C
|
| PFHd |
0.0000000044
|
| Mode of operation |
High demand mode
|
| Relative humidity |
90%
|
| Category |
Up to 4
|
| Hardware fault tolerance |
1
|
| MTTFd |
165 year
|
|---|---|
| DC avg |
99 %
|
| T cycle |
8 hr/8.28 s
|
| Mission time |
20 year
|
| Hours of operation |
24 h
|
| Days of operation |
365 dbays
|
| Performance level |
Up to e
|
| Evaluation input |
SWS input
|
| With detachable clamps |
True
|
|---|---|
| Rated control supply voltage at AC 50 Hz |
0 V
|
| Rated control supply voltage at AC 60 Hz |
0 V
|
| Vibration |
10...55 Hz, 0.35 mm
|
| Shock |
10 g, 16 ms
|
| Release-delay |
0 s
|
| Rail mounting possible |
True
|
| Mechanical life operations |
1.0E7
|
| Enclosure protection |
IP40 (NEMA 1)
|
| Height |
119.4 mm
|
|---|---|
| Width |
22.5 mm
|
| Depth |
113.6 mm
|
| Drawings | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
| General | Publication |
|---|---|
| Link to Application Examples Brochure | SAFETY-WD001 |
| Link to Application and Wiring Diagram Brochure | SAFETY-WD001 |
| Link to Online Catalog | -- |
| Link to Connection Diagrams | -- |
| Product Cutsheet | -- |
| Installation Instructions | Publication |
|---|---|
| 440r-in062_-mu-p | 440R-IN062 |
| Technical Data | Publication |
|---|---|
| 440r-td001_-en-p | 440R-TD001 |
| User Manual | Publication |
|---|---|
| 440r-um013_-en-p | 440R-UM013 |
This product was certified with the above certifications as of 2026-05-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for certification documents?
Explore certifications for this product and more in our comprehensive Literature Library.
| EU Importer Address |
Rockwell Automation N.V |
|---|---|
| EU Authorized Representative Address |
Rockwell Automation N.V |
| Technotes |
|---|
Overview
| Unique Product Identifier |
440R-EM4R2D
|
|---|---|
| UPC |
885630181691
|
| Estimated Lead Time |
5 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Multiple
|
The information provided by Rockwell Automation on www.rockwellautomation.com (the “Site”) is for demonstration purposes only and may be incomplete or inaccurate. All information is provided “as is”, and Rockwell Automation makes no representations or warranties of any kind, express or implied, regarding the accuracy, adequacy, validity, reliability, or completeness of any information on the Site. Use of this information is at your own risk.
Electrical & Connectivity
| Output |
4 Normally Open Delayed
|
|---|
| Number of outputs, safety related, undelayed, with contact |
0
|
|---|---|
| Number of outputs, safety related, delayed, with contact |
4
|
| Number of outputs, signalling function, undelayed, with contact |
0
|
| Number of outputs, safety related, undelayed, semiconductors |
0
|
| Number of outputs, safety related, delayed, semiconductors |
0
|
| Number of outputs, signalling function, undelayed, semiconductors |
0
|
| Number of outputs, signalling function, delayed, semiconductors |
0
|
| With start input |
False
|
| With muting function |
False
|
| Voltage type for actuating |
DC
|
| Rated control supply voltage at DC |
24 V
|
| Model |
Expansion device
|
| Type of electric connection |
Screw connection
|
| Evaluation inputs |
Other
|
| Power consumption |
3.5 W
|
| Continuous safety output current |
2A @ 24V DC (0.1 Hz), DC-13 (UL: B300)
|
| Wire size |
0.2 to 2.5 mm²
|
| Number of outputs, signalling function, delayed, with contact |
0
|
| With feedback circuit |
True
|
| Surge auxillary output current duration, max |
5 ms
|
| Aggregate current of outputs per module, max |
6 A
|
| Continuous auxiliary output current |
50 mA
|
| Surge auxiliary output current |
700 mA
|
| Other input |
SWS input
|
| Other output |
SWS output
|
| Operating voltage |
20.4 V
|
Compliance & Environment
| Safe failure fraction |
99 %
|
|---|---|
| Operating temperature |
-5 °C
|
| PFHd |
0.0000000044
|
| Mode of operation |
High demand mode
|
| Relative humidity |
90%
|
| Category |
Up to 4
|
| Hardware fault tolerance |
1
|
Technical Specifications
| MTTFd |
165 year
|
|---|---|
| DC avg |
99 %
|
| T cycle |
8 hr/8.28 s
|
| Mission time |
20 year
|
| Hours of operation |
24 h
|
| Days of operation |
365 dbays
|
| Performance level |
Up to e
|
| Evaluation input |
SWS input
|
Physical Characteristics
| With detachable clamps |
True
|
|---|---|
| Rated control supply voltage at AC 50 Hz |
0 V
|
| Rated control supply voltage at AC 60 Hz |
0 V
|
| Vibration |
10...55 Hz, 0.35 mm
|
| Shock |
10 g, 16 ms
|
| Release-delay |
0 s
|
| Rail mounting possible |
True
|
| Mechanical life operations |
1.0E7
|
| Enclosure protection |
IP40 (NEMA 1)
|
| Height |
119.4 mm
|
|---|---|
| Width |
22.5 mm
|
| Depth |
113.6 mm
|
Drawings
| Drawings | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
Documents
|
Link to Application Examples Brochure
General
SAFETY-WD001 |
|
Link to Application and Wiring Diagram Brochure
General
SAFETY-WD001 |
|
Link to Online Catalog
General
-- |
|
Link to Connection Diagrams
General
-- |
|
Product Cutsheet
General
-- |
|
440r-in062_-mu-p
Installation Instructions
440R-IN062 |
|
440r-td001_-en-p
Technical Data
440R-TD001 |
|
440r-um013_-en-p
User Manual
440R-UM013 |
| General | Publication |
|---|---|
| Link to Application Examples Brochure | SAFETY-WD001 |
| Link to Application and Wiring Diagram Brochure | SAFETY-WD001 |
| Link to Online Catalog | -- |
| Link to Connection Diagrams | -- |
| Product Cutsheet | -- |
| Installation Instructions | Publication |
| 440r-in062_-mu-p | 440R-IN062 |
| Technical Data | Publication |
| 440r-td001_-en-p | 440R-TD001 |
| User Manual | Publication |
| 440r-um013_-en-p | 440R-UM013 |
Certifications
This product was certified with the above certifications as of 2026-05-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for certification documents?
Explore certifications for this product and more in our comprehensive Literature Library.
| EU Importer Address |
Rockwell Automation N.V |
|---|---|
| EU Authorized Representative Address |
Rockwell Automation N.V |
Accessories
Alternative Products
Technotes
| Technotes |
|---|