Micro800 Isolated Serial Port Plug-In
Micro800 Isolated Serial Port Plug-In
| Unique Product Identifier |
2080-SERIALISOL
|
|---|---|
| UPC |
885630058429
|
| Estimated Lead Time |
28 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Singapore
|
The information provided by Rockwell Automation on www.rockwellautomation.com (the “Site”) is for demonstration purposes only and may be incomplete or inaccurate. All information is provided “as is”, and Rockwell Automation makes no representations or warranties of any kind, express or implied, regarding the accuracy, adequacy, validity, reliability, or completeness of any information on the Site. Use of this information is at your own risk.
| Mounting torque |
0.2 nm
|
|---|
| Cable length using RS485, Max |
1000
|
|---|---|
| Data transmission type |
Serial
|
| IO link master |
False
|
| Isolated voltage |
500V AC
|
| Redundancy |
False
|
| SIL according to IEC 61508 |
None
|
| Suitable for safety functions |
False
|
| Supporting protocol |
Modbus RTU (RS232 and RS485)
|
| Supporting protocol for AS-Interface Safety at Work |
False
|
| Supporting protocol for ASI |
False
|
| Supporting protocol for CAN |
False
|
| Supporting protocol for Data-Highway |
False
|
| Supporting protocol for DeviceNet |
True
|
| Supporting protocol for DeviceNet Safety |
True
|
| Supporting protocol for EtherNet/IP |
False
|
| Supporting protocol for Foundation Fieldbus |
False
|
| Supporting protocol for INTERBUS |
False
|
| Supporting protocol for INTERBUS-Safety |
False
|
| Supporting protocol for KNX |
False
|
| Supporting protocol for LON |
False
|
| Supporting protocol for Modbus |
False
|
| Supporting protocol for PROFIBUS |
False
|
| Supporting protocol for PROFINET CBA |
False
|
| Supporting protocol for PROFINET IO |
False
|
| Supporting protocol for PROFIsafe |
False
|
| Supporting protocol for SERCOS |
False
|
| Supporting protocol for SUCONET |
False
|
| Supporting protocol for SafetyBUS p |
False
|
| Supporting protocol for TCP/IP |
False
|
| Supporting protocol for other bus systems |
False
|
| Terminal screw torque |
0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)
|
| Transmission rate |
19.2 kbps
|
| Wire size |
0.14...1.5 mm² (26...16 AWG) solid copper wire or, 0.14...1.0 mm² (22...18 AWG) stranded copper wire, Rated at 90 °C (194 °F) insulation max
|
| With optical interface |
False
|
| With potential separation |
False
|
| Temperature Rating |
-20…65 °C (-4…149 °F)
|
|---|
| LCA Method |
ISO 14040/44 compliant
|
|---|---|
| Impact Assessment Method |
EF 3.0 (Environmental Footprint) ESPR aligned
|
| Database Used |
Ecoinvent 3.10
|
| Use Phase Electricity |
European Average Grid Mix (EU-40)
|
| Cradle To Grave |
11.8 kg CO2 eq
|
| Cradle To Gate |
4.58 kg CO2 eq
|
| Environmental Compliance | |
|---|---|
| SVHC Information | |
| Environmental Compliance | |
| SVHC Information |
| Conducted RF immunity |
IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
|
|---|---|
| EFT/B immunity |
IEC 61000-4-4: ± 2kV @ 5kHz on communication ports
|
| ESD immunity |
IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
|
| Emissions |
CISPR 11 (IEC 61000-6-4): Class A
|
| Nonoperating temperature |
-40...85 °C (-40...185 °F), IEC60068-2-1 (Test Ad, operating cold), IEC60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
|
| Operating temperature |
-20...65 °C (-4...149 °F), IEC 60068-2-1 (Test Ad, operating cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
|
| Radiated RF immunity |
IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
|
| Shock |
Operating: 25 G, IEC 60068-2-27 (Test Ea, unpackaged shock)
|
| Surge transient immunity |
IEC 61000-4-5: ± 2 kV line-earth(CM) on communication ports
|
| Surrounding air temperature, max |
65 °C
|
| Vibration |
IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz
|
| Drawings | |
|---|---|
| 3D STP (STEP) Model | Download (ZIP) |
| Product Drawing | Drawing (DXF) |
| Drawings |
|---|
| 3D STP (STEP) Model Download (ZIP) |
| Product Drawing Drawing (DXF) |
Click the Download CAD button below to view all file formats available for download.
| General | Publication |
|---|---|
| Brochure | -- |
| Wiring Diagram | -- |
| Product Cutsheet | -- |
| Installation Guide | -- |
| User Manual | Publication |
|---|---|
| 2080-um004_-en-e | 2080-UM004 |
| Micro800 Plug-in Modules User Manual | 2080-UM002 |
This product was certified with the above certifications as of 2026-11-17. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for certification documents?
Explore certifications for this product and more in our comprehensive Literature Library.
| EU Importer Address |
Rockwell Automation N.V |
|---|---|
| EU Authorized Representative Address |
Rockwell Automation N.V |
| Technotes |
|---|
Overview
| Unique Product Identifier |
2080-SERIALISOL
|
|---|---|
| UPC |
885630058429
|
| Estimated Lead Time |
28 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Singapore
|
The information provided by Rockwell Automation on www.rockwellautomation.com (the “Site”) is for demonstration purposes only and may be incomplete or inaccurate. All information is provided “as is”, and Rockwell Automation makes no representations or warranties of any kind, express or implied, regarding the accuracy, adequacy, validity, reliability, or completeness of any information on the Site. Use of this information is at your own risk.
Physical Characteristics
| Mounting torque |
0.2 nm
|
|---|
Electrical & Connectivity
| Cable length using RS485, Max |
1000
|
|---|---|
| Data transmission type |
Serial
|
| IO link master |
False
|
| Isolated voltage |
500V AC
|
| Redundancy |
False
|
| SIL according to IEC 61508 |
None
|
| Suitable for safety functions |
False
|
| Supporting protocol |
Modbus RTU (RS232 and RS485)
|
| Supporting protocol for AS-Interface Safety at Work |
False
|
| Supporting protocol for ASI |
False
|
| Supporting protocol for CAN |
False
|
| Supporting protocol for Data-Highway |
False
|
| Supporting protocol for DeviceNet |
True
|
| Supporting protocol for DeviceNet Safety |
True
|
| Supporting protocol for EtherNet/IP |
False
|
| Supporting protocol for Foundation Fieldbus |
False
|
| Supporting protocol for INTERBUS |
False
|
| Supporting protocol for INTERBUS-Safety |
False
|
| Supporting protocol for KNX |
False
|
| Supporting protocol for LON |
False
|
| Supporting protocol for Modbus |
False
|
| Supporting protocol for PROFIBUS |
False
|
| Supporting protocol for PROFINET CBA |
False
|
| Supporting protocol for PROFINET IO |
False
|
| Supporting protocol for PROFIsafe |
False
|
| Supporting protocol for SERCOS |
False
|
| Supporting protocol for SUCONET |
False
|
| Supporting protocol for SafetyBUS p |
False
|
| Supporting protocol for TCP/IP |
False
|
| Supporting protocol for other bus systems |
False
|
| Terminal screw torque |
0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)
|
| Transmission rate |
19.2 kbps
|
| Wire size |
0.14...1.5 mm² (26...16 AWG) solid copper wire or, 0.14...1.0 mm² (22...18 AWG) stranded copper wire, Rated at 90 °C (194 °F) insulation max
|
| With optical interface |
False
|
| With potential separation |
False
|
| Temperature Rating |
-20…65 °C (-4…149 °F)
|
|---|
Sustainability
| LCA Method |
ISO 14040/44 compliant
|
|---|---|
| Impact Assessment Method |
EF 3.0 (Environmental Footprint) ESPR aligned
|
| Database Used |
Ecoinvent 3.10
|
| Use Phase Electricity |
European Average Grid Mix (EU-40)
|
| Cradle To Grave |
11.8 kg CO2 eq
|
| Cradle To Gate |
4.58 kg CO2 eq
|
| Environmental Compliance | |
|---|---|
| SVHC Information | |
| Environmental Compliance | |
| SVHC Information |
Compliance & Environment
| Conducted RF immunity |
IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
|
|---|---|
| EFT/B immunity |
IEC 61000-4-4: ± 2kV @ 5kHz on communication ports
|
| ESD immunity |
IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges
|
| Emissions |
CISPR 11 (IEC 61000-6-4): Class A
|
| Nonoperating temperature |
-40...85 °C (-40...185 °F), IEC60068-2-1 (Test Ad, operating cold), IEC60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
|
| Operating temperature |
-20...65 °C (-4...149 °F), IEC 60068-2-1 (Test Ad, operating cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
|
| Radiated RF immunity |
IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz,
|
| Shock |
Operating: 25 G, IEC 60068-2-27 (Test Ea, unpackaged shock)
|
| Surge transient immunity |
IEC 61000-4-5: ± 2 kV line-earth(CM) on communication ports
|
| Surrounding air temperature, max |
65 °C
|
| Vibration |
IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz
|
Drawings
| Drawings | |
|---|---|
| 3D STP (STEP) Model | Download (ZIP) |
| Product Drawing | Drawing (DXF) |
| Drawings |
|---|
| 3D STP (STEP) Model Download (ZIP) |
| Product Drawing Drawing (DXF) |
Click the Download CAD button below to view all file formats available for download.
Documents
|
Brochure
General
-- |
|
Wiring Diagram
General
-- |
|
Product Cutsheet
General
-- |
|
Installation Guide
General
-- |
|
2080-um004_-en-e
User Manual
2080-UM004 |
|
Micro800 Plug-in Modules User Manual
User Manual
2080-UM002 |
| General | Publication |
|---|---|
| Brochure | -- |
| Wiring Diagram | -- |
| Product Cutsheet | -- |
| Installation Guide | -- |
| User Manual | Publication |
| 2080-um004_-en-e | 2080-UM004 |
| Micro800 Plug-in Modules User Manual | 2080-UM002 |
Certifications
This product was certified with the above certifications as of 2026-11-17. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for certification documents?
Explore certifications for this product and more in our comprehensive Literature Library.
| EU Importer Address |
Rockwell Automation N.V |
|---|---|
| EU Authorized Representative Address |
Rockwell Automation N.V |
Alternative Products
Technotes
| Technotes |
|---|