Loading
View all Stratix 2500 Lightly Managed Switches
Print
Share
QR code
JSON
  • alt text
  • alt text
alt text
alt text
Chevron LeftChevron Left
alt text
Chevron LeftChevron Left
alt text
2019_AB_Logo
Preferred
1783-lms8

Stratix2500 8Port Lightly Managed Switch

Serial #:
This product has not been verified. Please register your product to confirm authenticity.
  • alt text
  • alt text
alt text
alt text
Chevron LeftChevron Left
alt text
Chevron LeftChevron Left
alt text
2019_AB_Logo
Lifecycle status: Active
Product at a glance
Product Registration
Lifecycle status: Active
Product at a glance
Product Registration
Description
Stratix 2500 Switch, Lightly Managed with 8x10/100BaseT
  • Add to BOM
  • Register your product
  • Get support
Find your nearest distributor
Contact your distributor in {0}
Change location
PhonePhone
Find a partner
Overview
Technical Specifications
General
Mechanical
Electrical
Environmental
Drawings
Documents
Certifications
Accessories
Alternative Products
Technotes
Unique Product Identifier
1783-lms8
UPC
887172959462
Estimated Lead Time
88 days
Country of Origin
>1
Network Media
Male RJ45 to Male RJ45
# of Copper Ports Required
8 or less
# of Fiber Ports Required
None
Stratix Ethernet Family
Stratix 2500
Width
45.7 cm
Height
144.8 cm
Depth
115 cm
Torque, functional ground lug screw
0.51 nm
Torque, power terminal screw
0.19 nm
Number of ports 10/100 Mbps RJ45
8
Layer 2
False
Layer 3
False
Manageable
True
Pulse (digital) output
5.3 W
Power dissipation
5.3 W
Power Input
12 - 24V DC, 0.4 - 0.2 A (SELV)
Total number of ports
8
Wire size, ethernet connection
RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Ethernet
True
Wire size, DC power connection, solid or stranded copper wire rated at 30 °C, or greater, above the surrounding air temperature
0.82 mm²
Wire size, ground connection, solid or stranded copper wire
3.3 mm²
Wiring category on communication ports
2
Wiring category on power ports
2
Degree of protection (IP)
IP30
Housing base material
Open-style
Nominal position
T4
Delta connected motor power, max
T4
Temperature, surrounding air, maximum
60 °C
EFT/B immunity for IEC 61000-4-4 at 100 kHz on DC power ports
±3
EFT/B immunity for IEC 61000-4-4 at 100 kHz on Ethernet ports
±3
Emissions, CISPR11 (IEC 61000-6-4)
IEC 61000-6-4
ESD immunity, IEC 61000-4-2, air discharges
8 kV
ESD immunity, IEC 61000-4-2, contact discharges
6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz
3 kg/km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz
10 kg/km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz
10 kg/km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)
-20 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)
-20 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)
-20 °C
Ambient temperature, maximum
60 °C
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)
10 V
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz
10 kg/km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing
5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on communication ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports
±2
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports
±1
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)
-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)
-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)
-40 °C
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
2-Dimensional Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
2-Dimensional Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Application Techniques Publication
APPLICATION_TECHNIQUES_enet-at007_-en-p ENET-AT007
APPLICATION_TECHNIQUES_enet-at006_-en-p ENET-AT006
General Publication
Product Registration Link --
Product Cutsheet --
Installation Instructions Publication
1783-in016_-en-p 1783-IN016
Profile Publication
PROFILE_migrat-pp043_-en-p MIGRAT-PP043
Reference Manual Publication
REFERENCE_MANUAL_enet-rm002_-en-p ENET-RM002
User Manual Publication
1783-um009_-en-p 1783-UM009
USER_MANUAL_1783-um007_-en-p 1783-UM007
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Search the Literature Library
China CCC UL Listed UKCA DOC
  • Semiconductor Inds Immunit
  • China CCC
  • UL Listed
  • UL Listed Hazardous
  • UKCA DOC
  • MOROCCO DOC
  • UK EX CERTIFICATE

This product was certified with the above certifications as of {}. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Items Per Page:
1-1 of 1
Items Per Page:
1-1 of 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Overview
Unique Product Identifier
1783-lms8
UPC
887172959462
Estimated Lead Time
88 days
Country of Origin
>1
Technical Specifications
Network Media
Male RJ45 to Male RJ45
# of Copper Ports Required
8 or less
# of Fiber Ports Required
None
Stratix Ethernet Family
Stratix 2500
Width
45.7 cm
Height
144.8 cm
Depth
115 cm
Torque, functional ground lug screw
0.51 nm
Torque, power terminal screw
0.19 nm
Number of ports 10/100 Mbps RJ45
8
Layer 2
False
Layer 3
False
Manageable
True
Pulse (digital) output
5.3 W
Power dissipation
5.3 W
Power Input
12 - 24V DC, 0.4 - 0.2 A (SELV)
Total number of ports
8
Wire size, ethernet connection
RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Ethernet
True
Wire size, DC power connection, solid or stranded copper wire rated at 30 °C, or greater, above the surrounding air temperature
0.82 mm²
Wire size, ground connection, solid or stranded copper wire
3.3 mm²
Wiring category on communication ports
2
Wiring category on power ports
2
Degree of protection (IP)
IP30
Housing base material
Open-style
Nominal position
T4
Delta connected motor power, max
T4
Temperature, surrounding air, maximum
60 °C
EFT/B immunity for IEC 61000-4-4 at 100 kHz on DC power ports
±3
EFT/B immunity for IEC 61000-4-4 at 100 kHz on Ethernet ports
±3
Emissions, CISPR11 (IEC 61000-6-4)
IEC 61000-6-4
ESD immunity, IEC 61000-4-2, air discharges
8 kV
ESD immunity, IEC 61000-4-2, contact discharges
6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz
3 kg/km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz
10 kg/km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz
10 kg/km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)
-20 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)
-20 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)
-20 °C
Ambient temperature, maximum
60 °C
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)
10 V
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz
10 kg/km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing
5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on communication ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports
±2
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports
±1
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)
-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)
-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)
-40 °C
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
2-Dimensional Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
2-Dimensional Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Documents
APPLICATION_TECHNIQUES_enet-at007_-en-p Application Techniques
ENET-AT007
APPLICATION_TECHNIQUES_enet-at006_-en-p Application Techniques
ENET-AT006
Product Registration Link General
--
Product Cutsheet General
--
1783-in016_-en-p Installation Instructions
1783-IN016
PROFILE_migrat-pp043_-en-p Profile
MIGRAT-PP043
REFERENCE_MANUAL_enet-rm002_-en-p Reference Manual
ENET-RM002
1783-um009_-en-p User Manual
1783-UM009
USER_MANUAL_1783-um007_-en-p User Manual
1783-UM007
Application Techniques Publication
APPLICATION_TECHNIQUES_enet-at007_-en-p ENET-AT007
APPLICATION_TECHNIQUES_enet-at006_-en-p ENET-AT006
General Publication
Product Registration Link --
Product Cutsheet --
Installation Instructions Publication
1783-in016_-en-p 1783-IN016
Profile Publication
PROFILE_migrat-pp043_-en-p MIGRAT-PP043
Reference Manual Publication
REFERENCE_MANUAL_enet-rm002_-en-p ENET-RM002
User Manual Publication
1783-um009_-en-p 1783-UM009
USER_MANUAL_1783-um007_-en-p 1783-UM007
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Search the Literature Library
Certifications
China CCC UL Listed UKCA DOC
  • Semiconductor Inds Immunit
  • China CCC
  • UL Listed
  • UL Listed Hazardous
  • UKCA DOC
  • MOROCCO DOC
  • UK EX CERTIFICATE

This product was certified with the above certifications as of {}. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Accessories
Items Per Page:
1-1 of 1
Alternative Products
Items Per Page:
1-1 of 1
Technotes
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Stratix2500 8Port Lightly Managed Switch
CloseClose
1783-lms8
Close
Print
Phone:
Call
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
Environmental compliance inquiry
All fields with * are required.
This field is required
This field is required
This field is required
This field is required
This field is required
This field is required
Your inquiry has been successfully submitted.
Please allow up to 5 business days to receive a response to your inquiry.
You can now close this window.
There was an error submitting your inquiry.
Please try again.
Sign in to your Rockwell Automation account to submit a repair documentation request.
Sign In
Request repair documentation
All fields with * are required for processing your request.
Please enter your business email address
This field is required
This field is required
This field is required
This field is required
Documentation of liability insurance is required for anyone who is requesting documentation for product repairs.
UploadUpload
Please upload documentation of liability insurance.*
1 file selected
CloseClose
File size is too large. Must be less than 5 MB.
Accepted file types: zip, pdf; Maximum size: 5 MB.
This field is required
Right to Repair Terms and Conditions
Rockwell Automation is making, parts, and service documentation available at your request in compliance with applicable right to repair laws and regulations. By signing below, you are agreeing to the following terms and conditions of your purchase of Rockwell Automation genuine repair parts for repair of a Rockwell Automation product. As used below, “Self Service Repair Parts” means genuine Rockwell Automation parts (components of Rockwell Automation products) purchased from Rockwell Automation for installation in a Rockwell Automation product as part of a Self Service Repair. Self Service Repair Parts may be new or previously used genuine Rockwell Automation parts that have been tested and passed Rockwell Automation functional requirements. “Self Service Repair Tools” means equipment and related materials purchased for the purpose of performing repairs.
This field is required
Your request has been successfully submitted.
Please allow up to 5 business days to receive a response to your inquiry.
  1. Chevron LeftChevron Left Rockwell Automation Home
  2. Chevron LeftChevron Left Products
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose