MicroLogix 4 Point Input Module
MicroLogix 4 Point Input Module
| Unique Product Identifier |
1762-IT4
|
|---|---|
| UPC |
611320861662
|
| Estimated Lead Time |
5 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Malaysia
|
| Class |
Progmable Logic Controller
|
|---|---|
| Depth |
87
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Number Of Channels |
4 point
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| Thermocouple Type |
4 Channel, Thermocouple/Mv Module
|
| Accuracy |
Thermocouple T: (-270...230 °C), without autocalibration ±0.3500 °C/°C with temperature drift, maximum @ 0...60 °C ambient
|
|---|---|
| Analogue inputs configurable |
True
|
| Analogue outputs configurable |
False
|
| Bus current draw |
50mA @ 24V DC, maximum
|
| CJC accuracy |
±1.3 °C
|
| Cable impedance, max |
25
|
| Calibration |
The module performs autocalibration upon power-up and whenever a channel is enabled. You can also prog the module to calibrate every five minutes
|
| Conducted immunity |
IEC 1000-4-6: 10V @ 0.15...80MHz
|
| Fast transient burst |
IEC1000-4-4 2kV @ 5kHz
|
| Heat dissipation |
1.5 total W (the W per point, plus the minimum W, with all points enabled)
|
| Input channel configuration |
Via configuration software screen or the user prog (by writing a unique bit pattern into the module’s configuration file)
|
| Input group to bus isolation |
30V AC/30V DC working voltage type test: 720V DC @ 1min
|
| Input signal, configurable |
True
|
| Input, current |
False
|
| Input, resistance thermometer |
False
|
| Input, resistor |
False
|
| Input, thermocouple |
True
|
| Input, voltage |
False
|
| Module OK LED |
ON: module has power, has passed internal diagnostics, and is communicating over the bus, OFF: Any of the above is not true.
|
| Module power LED |
ON: indicates power is applied
|
| Normal mode rejection ratio |
85 dB min @ 60 Hz with the 10 or 60 Hz filter selected
|
| Number of analogue outputs |
4
|
| Open-circuit detection time |
7 ms
|
| Output signal configurable |
False
|
| Output, current |
False
|
| Output, voltage |
False
|
| Overload at input terminals |
Maximum @ ±35V DC continuous
|
| Radiated immunity |
IEC 61000-4-3: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Rated working voltage |
30V DC
|
| Resolution |
15 bit plus sign
|
| Response speed per channel |
Input filter and configuration dependent
|
| Suitable for safety functions |
False
|
| Surge immunity |
IEC1000-4-5: 1kV galvanic gun
|
| Type of electric connection |
Screw connection
|
| A/D converter type |
Delta-Sigma
|
|---|---|
| Channel diagnostics |
Over or under range or open circuit condition by bit reporting for analog inputs
|
| Common mode rejection |
>110 dB at 60 Hz (with 10 or 60 Hz filter)
|
| Common mode voltage range |
±10V
|
| Input impedance |
>10 MΩ
|
| Shipping weight |
220 g
|
|---|---|
| Shock |
Relay ops: 7.5 G panel mounted (5 G DIN rail mounted)
|
| Vibration |
Relay ops: 2 G
|
| Depth |
87 mm
|
|---|---|
| Height |
90 mm
|
| Recommended cable |
Belden™ 8761 (shielded), shielded thermocouple extension wire for the specific type of thermocouple you are using. Follow thermocouple manufacturer’s recommendations
|
| Width |
40 mm
|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
|---|---|
| Hazardous environment class |
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
| Operating altitude |
2000 m
|
| Operating humidity |
5...95% noncondensing
|
| Operating temperature |
-20 °C
|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Storage temperature |
-40 °C
|
| Input and output group to system isolation |
30V AC/30V DC working voltage type test: 500V AC or 707V DC @ 1min
|
|---|---|
| Repeatability |
Thermocouple T: ±1.5 °C for 10 Hz filter
|
| Drawings | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
| General | Publication |
|---|---|
| Product Cutsheet | -- |
| Selection Guide | 1761-SG001 |
This product was certified with the above certifications as of 2026-08-11. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for certification documents?
Explore certifications for this product and more in our comprehensive Literature Library.
| EU Importer Address |
Rockwell Automation N.V |
|---|---|
| EU Authorized Representative Address |
Rockwell Automation N.V |
| Technotes |
|---|
Overview
| Unique Product Identifier |
1762-IT4
|
|---|---|
| UPC |
611320861662
|
| Estimated Lead Time |
5 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Malaysia
|
Electrical & Connectivity
| Class |
Progmable Logic Controller
|
|---|---|
| Depth |
87
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Number Of Channels |
4 point
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| Thermocouple Type |
4 Channel, Thermocouple/Mv Module
|
| Accuracy |
Thermocouple T: (-270...230 °C), without autocalibration ±0.3500 °C/°C with temperature drift, maximum @ 0...60 °C ambient
|
|---|---|
| Analogue inputs configurable |
True
|
| Analogue outputs configurable |
False
|
| Bus current draw |
50mA @ 24V DC, maximum
|
| CJC accuracy |
±1.3 °C
|
| Cable impedance, max |
25
|
| Calibration |
The module performs autocalibration upon power-up and whenever a channel is enabled. You can also prog the module to calibrate every five minutes
|
| Conducted immunity |
IEC 1000-4-6: 10V @ 0.15...80MHz
|
| Fast transient burst |
IEC1000-4-4 2kV @ 5kHz
|
| Heat dissipation |
1.5 total W (the W per point, plus the minimum W, with all points enabled)
|
| Input channel configuration |
Via configuration software screen or the user prog (by writing a unique bit pattern into the module’s configuration file)
|
| Input group to bus isolation |
30V AC/30V DC working voltage type test: 720V DC @ 1min
|
| Input signal, configurable |
True
|
| Input, current |
False
|
| Input, resistance thermometer |
False
|
| Input, resistor |
False
|
| Input, thermocouple |
True
|
| Input, voltage |
False
|
| Module OK LED |
ON: module has power, has passed internal diagnostics, and is communicating over the bus, OFF: Any of the above is not true.
|
| Module power LED |
ON: indicates power is applied
|
| Normal mode rejection ratio |
85 dB min @ 60 Hz with the 10 or 60 Hz filter selected
|
| Number of analogue outputs |
4
|
| Open-circuit detection time |
7 ms
|
| Output signal configurable |
False
|
| Output, current |
False
|
| Output, voltage |
False
|
| Overload at input terminals |
Maximum @ ±35V DC continuous
|
| Radiated immunity |
IEC 61000-4-3: 10 V/m, 80...1000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Rated working voltage |
30V DC
|
| Resolution |
15 bit plus sign
|
| Response speed per channel |
Input filter and configuration dependent
|
| Suitable for safety functions |
False
|
| Surge immunity |
IEC1000-4-5: 1kV galvanic gun
|
| Type of electric connection |
Screw connection
|
| A/D converter type |
Delta-Sigma
|
|---|---|
| Channel diagnostics |
Over or under range or open circuit condition by bit reporting for analog inputs
|
| Common mode rejection |
>110 dB at 60 Hz (with 10 or 60 Hz filter)
|
| Common mode voltage range |
±10V
|
| Input impedance |
>10 MΩ
|
Physical Characteristics
| Shipping weight |
220 g
|
|---|---|
| Shock |
Relay ops: 7.5 G panel mounted (5 G DIN rail mounted)
|
| Vibration |
Relay ops: 2 G
|
| Depth |
87 mm
|
|---|---|
| Height |
90 mm
|
| Recommended cable |
Belden™ 8761 (shielded), shielded thermocouple extension wire for the specific type of thermocouple you are using. Follow thermocouple manufacturer’s recommendations
|
| Width |
40 mm
|
Compliance & Environment
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
|---|---|
| Hazardous environment class |
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
| Operating altitude |
2000 m
|
| Operating humidity |
5...95% noncondensing
|
| Operating temperature |
-20 °C
|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Storage temperature |
-40 °C
|
Technical Specifications
| Input and output group to system isolation |
30V AC/30V DC working voltage type test: 500V AC or 707V DC @ 1min
|
|---|---|
| Repeatability |
Thermocouple T: ±1.5 °C for 10 Hz filter
|
Drawings
| Drawings | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
Documents
|
Product Cutsheet
General
-- |
|
Selection Guide
General
1761-SG001 |
| General | Publication |
|---|---|
| Product Cutsheet | -- |
| Selection Guide | 1761-SG001 |
Certifications
This product was certified with the above certifications as of 2026-08-11. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for certification documents?
Explore certifications for this product and more in our comprehensive Literature Library.
| EU Importer Address |
Rockwell Automation N.V |
|---|---|
| EU Authorized Representative Address |
Rockwell Automation N.V |
Technotes
| Technotes |
|---|