MODULE_INFO - Plug-in and expansion module information

The following information provides the plug-in and expansion module type, module ID, vendor ID, product codes, and the revision word descriptions for expansion modules as defined by
Allen-Bradley
.

Plug-in module information

Plug-in module information defined by Allen-Bradley
Plug-in Module
Plug-in Type
Module ID
Vendor ID
Product Type
Product Code
2080-IF2
Analog
96
1
10
32
2080-IF4
Analog
98
1
10
33
2080-OF2
Analog
100
1
10
34
2080-TC2
Analog
102
1
10
35
2080-RTD2
Analog
104
1
10
36
2080-DNET20
Communication
34
1
12
249
2080-SERIALISOL
Communication
32
1
-
-
2080-IQ4
Digital
192
1
7
192
2080-OB4
Digital
193
1
7
193
2080-OV4
Digital
194
1
7
194
2080-IQ4OB4
Digital
195
1
7
195
2080-IQ4OV4
Digital
196
1
7
196
2080-OW4I
Digital
197
1
7
197
2080-MOT-HSC
Specialty
48
1
43
48
2080-TRIMPOT6
Specialty
72
1
-
-

Expansion module information

Expansion module information defined by Allen-Bradley
Model Number
Expansion Type
Module ID
Vendor ID
Product Type
Product Code
2085-IF4
Analog
-
1
10
208
2085-IF8
Analog
-
1
10
206
2085-IRT4
Analog
-
1
10
213
2085-OF4
Analog
-
1
10
214
2085-IA8
Digital
-
1
7
1148
2085-IM8
Digital
-
1
7
1152
2085-IQ16
Digital
-
1
7
1144
2085-IQ32T
Digital
-
1
7
1145
2085-OA8
Digital
-
1
7
1149
2085-OB16
Digital
-
1
7
1146
2085-OV16
Digital
-
1
7
1147
2085-OW16
Digital
-
1
7
1151
2085-OW8
Digital
-
1
7
1150

Expansion module Revision Word descriptions

Revision Word information for Allen-Bradley expansion modules
Bit
Name
Description
15
14
Max Baud Rate (1:0)
These bits identify the maximum frequency for Max Baud Rate (1:0).
  • 00 (bin) is 2 Mbps
  • 01 (bin) is 4 Mbps
  • 10 (bin) is 8 Mbps
  • 11 (bin) is 16 Mbps
13
12
11
10
Minor Revision (3:0)
Minor Revision (3:0) is the product minor revision designation. This field indicates the minor revision of the catalog number designated by the vendor ID, product type, product code, series, and major revision.
The minor revision ranges from 0 through 15.
9
8
7
6
5
Major Revision (4:0)
Major revision (4:0) is the product major revision designation. This field indicates the major revision of the catalog number designated by the vendor ID, product type, product code, and series.
The major ranges from 0 through 31.
4
Series (4:0)
SERIES (4:0) is the product series designation.
Series letter of SERIES (4:0) designated by the Vendor ID, Product Type, and Product Code
Series
(4:0)
Series
Series (4:0)
Series
Series
(4:0)
Series
Series (4:0)
Series
0
A
8
I
16
Q
24
Y
1
B
9
J
17
R
25
Z
2
C
10
K
18
S
26
AA
3
D
11
L
19
T
27
AB
4
E
12
M
20
U
28
AC
5
F
13
N
21
V
29
AD
6
G
14
O
22
W
30
AE
7
H
15
P
23
X
31
>AE
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.