Micro810 embedded I/O parameters
Use information in the following table to configure embedded I/O parameters for a
Micro810
controller.Setting | Description |
---|---|
Digital Input | |
Input | Displays the input number. Numbers are:
|
Input Filter | Specifies the time for the Micro810 controller to recognize the state change from an external input voltage once it reaches an ON or OFF state. The ON-OFF and the OFF-ON values are the same for DC filter times. Options are:
|
Analog Input | |
Input | Displays the input number. |
Gain | Specifies the increase of the signal's power or voltage from the input to the output. The value is from 50 through 150 for analog inputs and outputs. The default value is 100. |
Offset | Specifies the offset value. The value is from –100 through 100. The default value is 0. |
1. Available for 2080-LC10-12DWD, 2080-LC10-12QBB, and 2080-LC10-12QWB controllers. 2. Available for 2080-LC10-12AWA controllers. |