Online Values view

The Online Values view displays the statuses or states for the power supply, warnings, trips, local input and HOA status.

Online views

Controlled by: Controller/Peer 2-Wire or Controller/Peer 3-Wire
100-E-INT-X EtherNet/IP in-cabinet Overload, Non-Reversing
Sections
Parameters
Values
Starter
  • Forward
    Displays the activity status of the Forward direction of the contactor.
  • Motor current
    Displays the activity status of the Motor.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Warnings
  • Phase Loss
    Displays the activity status of the Phase loss warning.
  • Underload
    Displays the activity status of the Underload warning.
  • Overload
    Displays the activity status of the Overload warning.
  • Jam
    Displays the activity status of the Jam warning.
Data read from the device does not indicate active status.
Data read from the device indicates a warning condition exists.
Trips
  • Phase Loss
    Displays the activity status of the Phase loss trip.
  • Underload
    Displays the activity status of the Underload trip.
  • Overload
    Displays the activity status of the Overload trip.
  • Jam
    Displays the activity status of the Jam trip.
  • Test
    Displays the activity status of the Test trip.
Data read from the device does not indicate active status.
Data read from the device indicates a trip condition exists. The communication interface type does not match the  type configured in the project.
Local Input
  • Interlock
    Indicates the active or inactive status of the interlock.
Data read from the device indicates active status.
Data read from the device indicates an interlock condition status exists. The communication interface type does not match the  type configured in the project.
HOA Status
  • Hand
    Displays the activity status of the Hand mode from the HOA Status.
  • Off
    Displays the activity status of the Off mode from the HOA Status.
  • Auto
    Displays the activity status of the Auto mode from the HOA Status.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Controlled by: Controller, Peer 2-Wire, or Peer 3-Wire
100-E-INT-X EtherNet/IP in-cabinet Overload, Non-Reversing
Sections
Parameters
Values
Starter
  • Forward
    Displays the activity status of the Forward direction of the contactor.
  • Motor current
    Displays the activity status of the Motor.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Warnings
  • Phase Loss
    Displays the activity status of the Phase loss warning.
  • Underload
    Displays the activity status of the Underload warning.
  • Overload
    Displays the activity status of the Overload warning.
  • Jam
    Displays the activity status of the Jam warning.
Data read from the device does not indicate active status.
Data read from the device indicates a warning condition exists.
Trips
  • Phase Loss
    Displays the activity status of the Phase loss trip.
  • Underload
    Displays the activity status of the Underload trip.
  • Overload
    Displays the activity status of the Overload trip.
  • Jam
    Displays the activity status of the Jam trip.
  • Test
    Displays the activity status of the Test trip
Data read from the device does not indicate active status.
Data read from the device indicates a trip condition exists. The communication interface type does not match the  type configured in the project.
Local Input
  • Interlock
    Indicates the active or inactive status of the interlock.
Data read from the device indicates active status.
Data read from the device indicates an interlock condition status exists. The communication interface type does not match the  type configured in the project.
Controlled by: Controller/Peer 2-Wire or Controller/Peer 3-Wire
104-E-INT-X EtherNet/IP in-cabinet Overload, Reversing
Sections
Parameters
Values
Starter
  • Forward
    Displays the activity status of the Forward direction of the contactor.
  • Reverse
    Displays the actual status of the Reverse direction of the contactor.
  • Motor current
    Displays the activity status of the Motor.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Warnings
  • Phase Loss
    Displays the activity status of the Phase loss warning.
  • Underload
    Displays the activity status of the Underload warning.
  • Overload
    Displays the activity status of the Overload warning.
  • Jam
    Displays the activity status of the Jam warning.
Data read from the device does not indicate active status.
Data read from the device indicates a warning condition exists.
Trips
  • Phase Loss
    Displays the activity status of the Phase loss trip.
  • Underload
    Displays the activity status of the Underload trip.
  • Overload
    Displays the activity status of the Overload trip.
  • Jam
    Displays the activity status of the Jam trip.
  • Test
    Displays the activity status of the Test trip.
Data read from the device does not indicate active status.
Data read from the device indicates a trip condition exists. The communication interface type does not match the  type configured in the project.
Local Input
  • Interlock
    Indicates the active or inactive status of the interlock.
Data read from the device indicates active status.
Data read from the device indicates an interlock condition status exists. The communication interface type does not match the  type configured in the project.
HOA Status
  • Hand
    Displays the activity status of the Hand mode from the HOA Status.
  • Off
    Displays the activity status of the Off mode from the HOA Status.
  • Auto
    Displays the activity status of the Auto mode from the HOA Status.
Data read from the device does not indicate active status.
Data read from the device indicates active status
Controlled by: Controller, Peer 2-Wire, or Peer 3-Wire
104-E-INT-X EtherNet/IP in-cabinet Overload, Reversing
Sections
Parameters
Values
Starter
  • Forward
    Displays the activity status of the Forward direction of the contactor.
  • Reverse
    Displays the actual status of the Reverse direction of the contactor.
  • Motor current
    Displays the activity status of the Motor.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Warnings
  • Phase Loss
    Displays the activity status of the Phase loss warning.
  • Underload
    Displays the activity status of the Underload warning.
  • Overload
    Displays the activity status of the Overload warning.
  • Jam
    Displays the activity status of the Jam warning.
Data read from the device does not indicate active status.
Data read from the device indicates a warning condition exists.
Trips
  • Phase Loss
    Displays the activity status of the Phase loss trip.
  • Underload
    Displays the activity status of the Underload trip.
  • Overload
    Displays the activity status of the Overload trip.
  • Jam
    Displays the activity status of the Jam trip.
  • Test
    Displays the activity status of the Test trip.
Data read from the device does not indicate active status.
Data read from the device indicates a trip condition exists. The communication interface type does not match the  type configured in the project.
Local Input
  • Interlock
    Indicates the active or inactive status of the interlock.
Data read from the device indicates active status.
Data read from the device indicates an interlock condition status exists. The communication interface type does not match the  type configured in the project.
Controlled by: Controller/Peer 2-Wire or Controller/Peer 3-Wire
100-E-INT-X EtherNet/IP in-cabinet MPCB, Non-Reversing
Sections
Parameters
Values
Starter
  • Forward
    Displays the activity status of the Forward direction of the contactor.
  • Motor current
    Displays the activity status of the Motor.
  • Circuit breaker
    Displays the activity status of the Circuit breaker.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Warnings
  • Phase Loss
    Displays the activity status of the Phase loss warning.
  • Underload
    Displays the activity status of the Underload warning.
  • Overload
    Displays the activity status of the Overload warning.
  • Jam
    Displays the activity status of the Jam warning.
Data read from the device does not indicate active status.
Data read from the device indicates a warning condition exists.
Trips
  • Phase Loss
    Displays the activity status of the Phase loss trip.
  • Underload
    Displays the activity status of the Underload trip.
  • Overload
    Displays the activity status of the Overload trip.
  • Jam
    Displays the activity status of the Jam trip.
  • Test
    Displays the activity status of the Test trip.
  • Short Circuit
    Displays the activity status of the Short circuit trip.
  • Contractor weld
    Displays the activity status of the Contactor weld trip.
  • 140ME
    Displays the activity status of  the 140ME trip.
Data read from the device does not indicate active status.
Data read from the device indicates a trip condition exists. The communication interface type does not match the  type configured in the project.
Local Input
  • Interlock
    Indicates the active or inactive status of the interlock.
Data read from the device indicates active status.
Data read from the device indicates an interlock condition status exists. The communication interface type does not match the  type configured in the project.
HOA Status
  • Hand
    Displays the activity status of the Hand mode from the HOA Status.
  • Off
    Displays the activity status of the Off mode from the HOA Status.
  • Auto
    Displays the activity status of the Auto mode from the HOA Status.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Controlled by: Controller, Peer 2-Wire, or Peer 3-Wire
100-E-INT-X EtherNet/IP in-cabinet MPCB, Non-Reversing
Sections
Parameters
Values
Starter
  • Forward
    Displays the activity status of the Forward direction of the contactor.
  • Motor current
    Displays the activity status of the Motor.
  • Circuit breaker
    Displays the activity status of the Circuit breaker.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Warnings
  • Phase Loss
    Displays the activity status of the Phase loss warning.
  • Underload
    Displays the activity status of the Underload warning.
  • Overload
    Displays the activity status of the Overload warning.
  • Jam
    Displays the activity status of the Jam warning.
Data read from the device does not indicate active status.
Data read from the device indicates a warning condition exists.
Trips
  • Phase Loss
    Displays the activity status of the Phase loss trip.
  • Underload
    Displays the activity status of the Underload trip.
  • Overload
    Displays the activity status of the Overload trip.
  • Jam
    Displays the activity status of the Jam trip.
  • Test
    Displays the activity status of the Test trip.
  • Short Circuit
    Displays the activity status of the Short circuit trip.
  • Contractor weld
    Displays the activity status of the Contactor weld trip.
  • 140ME
    Displays the activity status of  the 140ME trip.
Data read from the device does not indicate active status.
Data read from the device indicates a trip condition exists. The communication interface type does not match the  type configured in the project.
Local Input
  • Interlock
    Indicates the active or inactive status of the interlock.
Data read from the device indicates active status.
Data read from the device indicates an interlock condition status exists. The communication interface type does not match the  type configured in the project.
Controlled by: Controller/Peer 2-Wire or Controller/Peer 3-Wire
104-E-INT-X EtherNet/IP in-cabinet MPCB, Reversing
Sections
Parameters
Values
Starter
  • Forward
    Displays the activity status of the Forward direction of the contactor.
  • Reverse
    Displays the actual status of the Reverse direction of the contactor.
  • Motor current
    Displays the activity status of the Motor.
  • Circuit breaker
    Displays the activity status of the Circuit breaker.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Warnings
  • Phase Loss
    Displays the activity status of the Phase loss warning.
  • Underload
    Displays the activity status of the Underload warning.
  • Overload
    Displays the activity status of the Overload warning.
  • Jam
    Displays the activity status of the Jam warning.
Data read from the device does not indicate active status.
Data read from the device indicates a warning condition exists.
Trips
  • Phase Loss
    Displays the activity status of the Phase loss trip.
  • Underload
    Displays the activity status of the Underload trip.
  • Overload
    Displays the activity status of the Overload trip.
  • Jam
    Displays the activity status of the Jam trip.
  • Test
    Displays the activity status of the Test trip.
  • Short Circuit
    Displays the activity status of the Short circuit trip.
  • Contractor weld
    Displays the activity status of the Contactor weld trip.
  • 140ME
    Displays the activity status of  the 140ME trip.
Data read from the device does not indicate active status.
Data read from the device indicates a trip condition exists. The communication interface type does not match the  type configured in the project.
Local Input
  • Interlock
    Indicates the active or inactive status of the interlock.
Data read from the device indicates active status.
Data read from the device indicates an interlock condition status exists. The communication interface type does not match the  type configured in the project.
HOA Status
  • Hand
    Displays the activity status of the Hand mode from the HOA Status.
  • Off
    Displays the activity status of the Off mode from the HOA Status.
  • Auto
    Displays the activity status of the Auto mode from the HOA Status.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Controlled by: Controller, Peer 2-Wire, or Peer 3-Wire
104-E-INT-X EtherNet/IP in-cabinet MPCB, Reversing
Sections
Parameters
Values
Starter
  • Forward
    Displays the activity status of the Forward direction of the contactor.
  • Reverse
    Displays the actual status of the Reverse direction of the contactor.
  • Motor current
    Displays the activity status of the Motor.
  • Circuit breaker
    Displays the activity status of the Circuit breaker.
Data read from the device does not indicate active status.
Data read from the device indicates active status.
Warnings
  • Phase Loss
    Displays the activity status of the Phase loss warning.
  • Underload
    Displays the activity status of the Underload warning.
  • Overload
    Displays the activity status of the Overload warning.
  • Jam
    Displays the activity status of the Jam warning.
Data read from the device does not indicate active status.
Data read from the device indicates a warning condition exists.
Trips
  • Phase Loss
    Displays the activity status of the Phase loss trip.
  • Underload
    Displays the activity status of the Underload trip.
  • Overload
    Displays the activity status of the Overload trip.
  • Jam
    Displays the activity status of the Jam trip.
  • Test
    Displays the activity status of the Test trip.
  • Short Circuit
    Displays the activity status of the Short circuit trip.
  • Contractor weld
    Displays the activity status of the Contactor weld trip.
  • 140ME
    Displays the activity status of  the 140ME trip.
Data read from the device does not indicate active status.
Data read from the device indicates a trip condition exists. The communication interface type does not match the  type configured in the project.
Local Input
  • Interlock
    Indicates the active or inactive status of the interlock.
Data read from the device indicates active status.
Data read from the device indicates an interlock condition status exists. The communication interface type does not match the  type configured in the project.
TIP:
Online values only appear when the unit is connected online.
Values are hidden when offline or the device type in the project does not match the physical device.
Some features will not show a value when the feature is not enabled in the configuration.
Buttons
Label
Description
Refresh
Manually refreshes data in the view when online with the device. When the button is selected, the AOP reads data from the device by using the CIP explicit messages.
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.
Normal