Configure input point parameters
Configure input point parameters for the input device.
- On the tab for the device, selectPoints.
- In thePointsview, under theInput Pointssection, configure the following parameters as needed:
- Point Mode. Select the points' input mode.
- Test Source. IfPoint Modeis set toSafety Pulse Test, select the output terminal associated with the pulse test.
- Input Delay Time Off -> On. Select the amount of time for an Off to On transition delay.
- Input Delay Time On -> Off. Select the amount of time for an On to Off transition delay.
- Transition Time Limit. If available, select the amount of time that the device ignores a discrepancy in input detection so that a slow changing signal does not report a fault.
- InInput Error Latch Time, enter the time the device holds an error to make sure that the controller can detect the error and provide more accurate diagnostics.
- SelectOK.