| Lamp Test Type |
Push-to-Test Type
|
|---|---|
| Type |
30mm Pilot Light
|
| Hole diameter |
30.5 mm
|
|---|---|
| Type of electric connection |
Screw connection
|
| Operator mechanical design life (cycles, min.) |
250000
|
| Contact block electrical design life (cycles, at max. load) |
1000000
|
| Enclosure compatibility (NEMA type) |
1, 4, 4X, 12, 13
|
| Operator function |
Push-to-test
|
| Operator type |
Pilot light, with lA test feature
|
| Vibration |
10 G maximum
|
| Shock |
25 G (contact fragility)/100 G (no damage)
|
| Contact block termination wire range |
14 - 18 AWG (x2)
|
| Illumination module termination wire range |
14 - 18 AWG (x2)
|
| Contact block termination tightening torque |
6 - 8 in-lb / 0.7 - 0.9 N-m
|
| Illumination module termination tightening torque |
6 - 8 in-lb / 0.7 - 0.9 N-m
|
| Terminations with finger safe covers |
No
|
|---|---|
| Operator cap/button shape |
Round
|
| Operator cap type |
Fresnal
|
| Operator cap color |
Red
|
| Operator cap/button material |
Plastic
|
| Contact block configuration |
1-NO 1-NC standard contacts
|
| Contact block thermal current rating |
10 A
|
|---|---|
| Contact block utilization category (AC) |
A600, AC-15
|
| Illumination lamp type |
Incandescent
|
| Contact block operational voltage, max |
600V AC @ 600V DC
|
| Contact block utilization category (DC) |
Q600, DC-13
|
| Operator construction/material |
Plastic
|
| Illumination module type |
Transformer
|
| Illumination module input voltage |
240V AC @ 50/60Hz
|
| Suitable for illumination |
Yes
|
| Operating temperature |
-25 °C
|
|---|---|
| Hazardous location rating |
No
|
| Humidity |
50 %
|
| Storage temperature |
-40 °C
|
| Certifications |
ABS, CCC, CE, CSA, EAC, GOST, UL
|
|---|
| Desenhos | |
|---|---|
| 3D STEP Model (STP) | Download (ZIP) |
| Desenhos |
|---|
| 3D STEP Model (STP) Download (ZIP) |
Faça login na sua conta Rockwell Automation para visualizar e baixar desenhos técnicos.
Entrar
| Type | Recurso | Publicação |
|---|---|---|
| General | Specification | 800-TD009 |
| General | Selection Guide | 800T-BR012 |
| General | Push my Buttons Podcast | -- |
| General | Repair Parts List | -- |
| General | Product Cutsheet | -- |
Procurando mais documentação?
Encontre documentação técnica selecionada para este produto no Centro de Documentação Técnica ou pesquise em nossa Biblioteca de Literatura.
Pesquise na Biblioteca de Literatura
Procurando por mais notas técnicas?
Encontre perguntas e respostas de especialistas técnicos da Rockwell Automation sobre este produto em nossa Base de conhecimento.
Pesquisar na Base de conhecimento
Especificações técnicas
| Lamp Test Type |
Push-to-Test Type
|
|---|---|
| Type |
30mm Pilot Light
|
| Hole diameter |
30.5 mm
|
|---|---|
| Type of electric connection |
Screw connection
|
| Operator mechanical design life (cycles, min.) |
250000
|
| Contact block electrical design life (cycles, at max. load) |
1000000
|
| Enclosure compatibility (NEMA type) |
1, 4, 4X, 12, 13
|
| Operator function |
Push-to-test
|
| Operator type |
Pilot light, with lA test feature
|
| Vibration |
10 G maximum
|
| Shock |
25 G (contact fragility)/100 G (no damage)
|
| Contact block termination wire range |
14 - 18 AWG (x2)
|
| Illumination module termination wire range |
14 - 18 AWG (x2)
|
| Contact block termination tightening torque |
6 - 8 in-lb / 0.7 - 0.9 N-m
|
| Illumination module termination tightening torque |
6 - 8 in-lb / 0.7 - 0.9 N-m
|
| Terminations with finger safe covers |
No
|
|---|---|
| Operator cap/button shape |
Round
|
| Operator cap type |
Fresnal
|
| Operator cap color |
Red
|
| Operator cap/button material |
Plastic
|
| Contact block configuration |
1-NO 1-NC standard contacts
|
| Contact block thermal current rating |
10 A
|
|---|---|
| Contact block utilization category (AC) |
A600, AC-15
|
| Illumination lamp type |
Incandescent
|
| Contact block operational voltage, max |
600V AC @ 600V DC
|
| Contact block utilization category (DC) |
Q600, DC-13
|
| Operator construction/material |
Plastic
|
| Illumination module type |
Transformer
|
| Illumination module input voltage |
240V AC @ 50/60Hz
|
| Suitable for illumination |
Yes
|
| Operating temperature |
-25 °C
|
|---|---|
| Hazardous location rating |
No
|
| Humidity |
50 %
|
| Storage temperature |
-40 °C
|
| Certifications |
ABS, CCC, CE, CSA, EAC, GOST, UL
|
|---|
Desenhos
| Desenhos | |
|---|---|
| 3D STEP Model (STP) | Download (ZIP) |
| Desenhos |
|---|
| 3D STEP Model (STP) Download (ZIP) |
Faça login na sua conta Rockwell Automation para visualizar e baixar desenhos técnicos.
Entrar
Documentos
|
Specification
General
800-TD009 |
|
Selection Guide
General
800T-BR012 |
|
Push my Buttons Podcast
General
-- |
|
Repair Parts List
General
-- |
|
Product Cutsheet
General
-- |
| Type | Recurso | Publicação |
|---|---|---|
| General | Specification | 800-TD009 |
| General | Selection Guide | 800T-BR012 |
| General | Push my Buttons Podcast | -- |
| General | Repair Parts List | -- |
| General | Product Cutsheet | -- |
Procurando mais documentação?
Encontre documentação técnica selecionada para este produto no Centro de Documentação Técnica ou pesquise em nossa Biblioteca de Literatura.
Pesquise na Biblioteca de Literatura
Acessórios
Produtos alternativos
Notas técnicas
Procurando por mais notas técnicas?
Encontre perguntas e respostas de especialistas técnicos da Rockwell Automation sobre este produto em nossa Base de conhecimento.
Pesquisar na Base de conhecimento
Loading
Copyright ©2026 Rockwell Automation, Inc.