| Voltage type for actuating |
AC/DC
|
|---|---|
| Rated control supply voltage at DC |
100 V
|
| Rated control supply voltage at AC 50 Hz |
100 V
|
| Rated control supply voltage at AC 60 Hz |
100 V
|
| Mounting method |
DIN-rail/screw
|
| Number of contact as normally closed |
2
|
| Number of contact as normally open |
2
|
| Contact form |
4-pole
|
| Rated frequency |
50/60 Hz
|
| Rated insulation voltage (Ui) |
690V per IEC
|
| Rated insulation voltage |
600V DC per UL/CSA
|
| Switching of AC Loads |
6 A @ 42-48V, AC-15
|
| Switching capacity |
Q600 @ DC per UL/CSA
|
| Contact rating, continuous |
2.5A @ 40°C per UL/CSA
|
| Operating limits, dropout |
(≤0.60) x Us @ DC control
|
| AC coil voltage |
6A @ 120V, AC-15
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ 50/60 Hz
|
| Rated voltage (Ue) |
24, 48, 120, 230, 400, 500, 690V AC
|
| Switching of DC loads |
6A @ 24V DC, DC-13 switching electromagnets
|
| Rated thermal current (Ith) |
4-poles: 16 A @ ≤40 °C, AC-12
|
| Rated impulse withstand voltage (Uimp) |
6 kV
|
| Rated impulse strength (Uimp) |
6 kV
|
| Conventional thermal current (Ith) |
10 A
|
| Dielectric withstand |
2.5 kV
|
| Rated operational voltage (Ue) |
690 V
|
| VA rating, break |
720
|
| VA rating, make |
7200
|
| Load |
12V @ 3mA (Silver), minimum
|
| Electric service life |
1.5 mon (AC-15 240V @ 3A)
|
| Coil voltage pickup |
85...110% AC coils, 80...110% DC coils
|
| Type of protection |
IP2X (IEC 60529 and DIN 40050), in connected state
|
| Operating time, closing delay |
40 ms
|
|---|---|
| Connection type |
Screw connection
|
| Operating time, opening delay |
11 to 95 ms
|
| Contact material |
Silver
|
| Shock resistance |
IEC 60068-2: Half sinusoidal shock 11 ms, 25G (in 3 directions
|
| Suitable for manual operation |
No
|
| Mechanical life |
20 mil
|
| Vibration resistance |
IEC 60068-2: Static >2 G, in normal position no malfunction <5 G
|
| Features |
Mechanically linked contacts, Timer and latch ops, Switch up to 690V AC and DC
|
| Height |
Approx 86 mm
|
|---|---|
| Length |
Approx 45 mm
|
| Width |
Approx 77 mm
|
| Altitude |
3000 m
|
|---|---|
| Ambient temperature |
Storage: -60...80 °C
|
| Standards compliance |
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, RoHS
|
|---|
| Dessins | |
|---|---|
| 3D STEP (STP) Model | Télécharger (ZIP) |
| 2D Drawing (PDF) | Télécharger (PDF) |
| Product Drawing | Drawing (DXF) |
| Dessins |
|---|
| 3D STEP (STP) Model Télécharger (ZIP) |
| 2D Drawing (PDF) Télécharger (PDF) |
| Product Drawing Drawing (DXF) |
| Type | Ressource | Publication |
|---|---|---|
| Général | Product Cutsheet | -- |
| Technical Data | 700-td552_-en-p | 700-TD552 |
Vous recherchez plus de documentation ?
Recherchez une documentation technique organisée pour ce produit dans le Centre de documentation technique ou recherchez dans notre bibliothèque documentaire complète.
Rechercher dans la bibliothèque littéraire
- China CCC
- CE
- Australian RCM
- Eurasion Economic Community
- UL Listed
- Registro Italiano Navale
- MOROCCO DOC
- UKCA DOC
This product was certified with the above certifications as of 2025-09-09. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Vous recherchez plus de notes techniques ?
Trouvez des questions et des réponses des experts techniques de Rockwell Automation pour ce produit dans notre base de connaissances.
Rechercher dans la base de connaissances
Spécifications techniques
| Voltage type for actuating |
AC/DC
|
|---|---|
| Rated control supply voltage at DC |
100 V
|
| Rated control supply voltage at AC 50 Hz |
100 V
|
| Rated control supply voltage at AC 60 Hz |
100 V
|
| Mounting method |
DIN-rail/screw
|
| Number of contact as normally closed |
2
|
| Number of contact as normally open |
2
|
| Contact form |
4-pole
|
| Rated frequency |
50/60 Hz
|
| Rated insulation voltage (Ui) |
690V per IEC
|
| Rated insulation voltage |
600V DC per UL/CSA
|
| Switching of AC Loads |
6 A @ 42-48V, AC-15
|
| Switching capacity |
Q600 @ DC per UL/CSA
|
| Contact rating, continuous |
2.5A @ 40°C per UL/CSA
|
| Operating limits, dropout |
(≤0.60) x Us @ DC control
|
| AC coil voltage |
6A @ 120V, AC-15
|
| Operating limits, pick-up |
(0.85...1.1) x Us @ 50/60 Hz
|
| Rated voltage (Ue) |
24, 48, 120, 230, 400, 500, 690V AC
|
| Switching of DC loads |
6A @ 24V DC, DC-13 switching electromagnets
|
| Rated thermal current (Ith) |
4-poles: 16 A @ ≤40 °C, AC-12
|
| Rated impulse withstand voltage (Uimp) |
6 kV
|
| Rated impulse strength (Uimp) |
6 kV
|
| Conventional thermal current (Ith) |
10 A
|
| Dielectric withstand |
2.5 kV
|
| Rated operational voltage (Ue) |
690 V
|
| VA rating, break |
720
|
| VA rating, make |
7200
|
| Load |
12V @ 3mA (Silver), minimum
|
| Electric service life |
1.5 mon (AC-15 240V @ 3A)
|
| Coil voltage pickup |
85...110% AC coils, 80...110% DC coils
|
| Type of protection |
IP2X (IEC 60529 and DIN 40050), in connected state
|
| Operating time, closing delay |
40 ms
|
|---|---|
| Connection type |
Screw connection
|
| Operating time, opening delay |
11 to 95 ms
|
| Contact material |
Silver
|
| Shock resistance |
IEC 60068-2: Half sinusoidal shock 11 ms, 25G (in 3 directions
|
| Suitable for manual operation |
No
|
| Mechanical life |
20 mil
|
| Vibration resistance |
IEC 60068-2: Static >2 G, in normal position no malfunction <5 G
|
| Features |
Mechanically linked contacts, Timer and latch ops, Switch up to 690V AC and DC
|
| Height |
Approx 86 mm
|
|---|---|
| Length |
Approx 45 mm
|
| Width |
Approx 77 mm
|
| Altitude |
3000 m
|
|---|---|
| Ambient temperature |
Storage: -60...80 °C
|
| Standards compliance |
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, RoHS
|
|---|
Dessins
| Dessins | |
|---|---|
| 3D STEP (STP) Model | Télécharger (ZIP) |
| 2D Drawing (PDF) | Télécharger (PDF) |
| Product Drawing | Drawing (DXF) |
| Dessins |
|---|
| 3D STEP (STP) Model Télécharger (ZIP) |
| 2D Drawing (PDF) Télécharger (PDF) |
| Product Drawing Drawing (DXF) |
Documents
|
Product Cutsheet
Général
-- |
|
700-td552_-en-p
Technical Data
700-TD552 |
| Type | Ressource | Publication |
|---|---|---|
| Général | Product Cutsheet | -- |
| Technical Data | 700-td552_-en-p | 700-TD552 |
Vous recherchez plus de documentation ?
Recherchez une documentation technique organisée pour ce produit dans le Centre de documentation technique ou recherchez dans notre bibliothèque documentaire complète.
Rechercher dans la bibliothèque littéraire
Certifications
- China CCC
- CE
- Australian RCM
- Eurasion Economic Community
- UL Listed
- Registro Italiano Navale
- MOROCCO DOC
- UKCA DOC
This product was certified with the above certifications as of 2025-09-09. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Accessoires
Notes techniques
Vous recherchez plus de notes techniques ?
Trouvez des questions et des réponses des experts techniques de Rockwell Automation pour ce produit dans notre base de connaissances.
Rechercher dans la base de connaissances
Loading
Copyright ©2026 Rockwell Automation, Inc.