| Power Supply |
24V DC
|
|---|
| Number of outputs, safety related, undelayed, with contact |
2
|
|---|---|
| Number of outputs, safety related, delayed, with contact |
0
|
| Number of outputs, signalling function, undelayed, with contact |
0
|
| Number of outputs, safety related, undelayed, semiconductors |
0
|
| Number of outputs, safety related, delayed, semiconductors |
0
|
| Number of outputs, signalling function, undelayed, semiconductors |
1
|
| Number of outputs, signalling function, delayed, semiconductors |
0
|
| With start input |
No
|
| With muting function |
No
|
| Voltage type for actuating |
DC
|
| Rated control supply voltage at DC |
24 V
|
| Model |
Basic device
|
| Type of electric connection |
Screw connection
|
| Evaluation inputs |
One- and two-channel
|
| Power consumption |
2.5 W
|
| Continuous safety output current |
UL: C300, AC-15: 1.5 A/250V AC, DC-13: 2 A/24V DC (0.1 Hz)
|
| Wire size |
0.2 to 2.5 mm²
|
| Number of outputs, signalling function, delayed, with contact |
0
|
| With feedback circuit |
Yes
|
| Suitable for monitoring of magnetic switches |
Yes
|
| Suitable for monitoring of proximity switches |
Yes
|
| Suitable for monitoring of emergency-stop circuits |
Yes
|
| Suitable for monitoring of optoelectronic protection equipment |
Yes
|
| Suitable for monitoring of position switches |
Yes
|
| Suitable for monitoring of tactile sensors |
Yes
|
| Suitable for monitoring of valves |
Yes
|
| Surge auxillary output current duration, max |
5 ms
|
| Aggregate current of outputs per module, max |
6 A
|
| Surge safety output current duration, max |
5 ms
|
| Continuous auxiliary output current |
50 mA
|
| Surge Aux output current |
700 mA
|
| Surge safety output current, max |
1.5 A
|
| Other output |
SWS output
|
| Operating voltage |
20.4 V
|
| SIL according to IEC 61508 |
3
|
|---|---|
| With approval according to UL |
Yes
|
| Stop category according to IEC 60204 |
0
|
| Performance level according to EN ISO 13849-1 |
Level e
|
| Type of safety according to IEC 61496-1 |
4
|
| With approval for TUV |
Yes
|
| With detachable clamps |
Yes
|
|---|---|
| Rated control supply voltage at AC 50 Hz |
0 V
|
| Rated control supply voltage at AC 60 Hz |
0 V
|
| Vibration |
10...55 Hz, 0.35 mm
|
| Shock |
Shock proof, operating: 10 G, 16 ms
|
| Release-delay |
0 s
|
| Rail mounting possible |
Yes
|
| Mechanical life operations |
1.0E7
|
| Enclosure protection |
IP40 (NEMA 1)
|
| MTTFd |
262 year
|
|---|---|
| DC avg |
99 %
|
| T cycle |
8/8.28 (h/s)
|
| Mission time |
20 year
|
| Hours of operation |
24 h
|
| Days of operation |
365 dbays
|
| Performance level |
Up to e
|
| Operating temperature |
-5 °C
|
|---|---|
| Relative humidity |
90%
|
| Height |
119.4 mm
|
|---|---|
| Width |
22.5 mm
|
| Depth |
113.6 mm
|
| Dibujos | |
|---|---|
| 3-Dimensional STEP model (STP) | Descargar (ZIP) |
| Product Drawing | Drawing (DWG) |
| Dibujos |
|---|
| 3-Dimensional STEP model (STP) Descargar (ZIP) |
| Product Drawing Drawing (DWG) |
Inicie sesión en su cuenta de Rockwell Automation para ver y descargar dibujos técnicos.
Registrarse
| Tipo | Recurso | Publicación |
|---|---|---|
| General | Link to Connection Diagrams | -- |
| General | Link to Online Catalog | -- |
| General | Link to Application and Wiring Diagram Brochure | SAFETY-WD001 |
| General | Product Cutsheet | -- |
| General | Link to Application Examples Brochure | SAFETY-WD001 |
| Installation Instructions | 440r-in042_-mu-p | 440R-IN042 |
| User Manual | 440r-um013_-en-p | 440R-UM013 |
¿Busca más documentación?
Encuentre documentación técnica seleccionada para este producto en el Centro de Documentación Técnica o busque en nuestra biblioteca de literatura.
Visite el Centro de Documentación Técnica
Busque en la biblioteca de literatura
- China CCC
- Korean KC
- Kosha Approval
This product was certified with the above certifications as of 2025-09-09. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
¿Busca más notas técnicas?
Encuentre preguntas y respuestas de los expertos técnicos de Rockwell Automation para este producto en nuestra base de conocimientos.
Buscar en la Base de Conocimientos
Especificaciones técnicas
| Power Supply |
24V DC
|
|---|
| Number of outputs, safety related, undelayed, with contact |
2
|
|---|---|
| Number of outputs, safety related, delayed, with contact |
0
|
| Number of outputs, signalling function, undelayed, with contact |
0
|
| Number of outputs, safety related, undelayed, semiconductors |
0
|
| Number of outputs, safety related, delayed, semiconductors |
0
|
| Number of outputs, signalling function, undelayed, semiconductors |
1
|
| Number of outputs, signalling function, delayed, semiconductors |
0
|
| With start input |
No
|
| With muting function |
No
|
| Voltage type for actuating |
DC
|
| Rated control supply voltage at DC |
24 V
|
| Model |
Basic device
|
| Type of electric connection |
Screw connection
|
| Evaluation inputs |
One- and two-channel
|
| Power consumption |
2.5 W
|
| Continuous safety output current |
UL: C300, AC-15: 1.5 A/250V AC, DC-13: 2 A/24V DC (0.1 Hz)
|
| Wire size |
0.2 to 2.5 mm²
|
| Number of outputs, signalling function, delayed, with contact |
0
|
| With feedback circuit |
Yes
|
| Suitable for monitoring of magnetic switches |
Yes
|
| Suitable for monitoring of proximity switches |
Yes
|
| Suitable for monitoring of emergency-stop circuits |
Yes
|
| Suitable for monitoring of optoelectronic protection equipment |
Yes
|
| Suitable for monitoring of position switches |
Yes
|
| Suitable for monitoring of tactile sensors |
Yes
|
| Suitable for monitoring of valves |
Yes
|
| Surge auxillary output current duration, max |
5 ms
|
| Aggregate current of outputs per module, max |
6 A
|
| Surge safety output current duration, max |
5 ms
|
| Continuous auxiliary output current |
50 mA
|
| Surge Aux output current |
700 mA
|
| Surge safety output current, max |
1.5 A
|
| Other output |
SWS output
|
| Operating voltage |
20.4 V
|
| SIL according to IEC 61508 |
3
|
|---|---|
| With approval according to UL |
Yes
|
| Stop category according to IEC 60204 |
0
|
| Performance level according to EN ISO 13849-1 |
Level e
|
| Type of safety according to IEC 61496-1 |
4
|
| With approval for TUV |
Yes
|
| With detachable clamps |
Yes
|
|---|---|
| Rated control supply voltage at AC 50 Hz |
0 V
|
| Rated control supply voltage at AC 60 Hz |
0 V
|
| Vibration |
10...55 Hz, 0.35 mm
|
| Shock |
Shock proof, operating: 10 G, 16 ms
|
| Release-delay |
0 s
|
| Rail mounting possible |
Yes
|
| Mechanical life operations |
1.0E7
|
| Enclosure protection |
IP40 (NEMA 1)
|
| MTTFd |
262 year
|
|---|---|
| DC avg |
99 %
|
| T cycle |
8/8.28 (h/s)
|
| Mission time |
20 year
|
| Hours of operation |
24 h
|
| Days of operation |
365 dbays
|
| Performance level |
Up to e
|
| Operating temperature |
-5 °C
|
|---|---|
| Relative humidity |
90%
|
| Height |
119.4 mm
|
|---|---|
| Width |
22.5 mm
|
| Depth |
113.6 mm
|
Dibujos
| Dibujos | |
|---|---|
| 3-Dimensional STEP model (STP) | Descargar (ZIP) |
| Product Drawing | Drawing (DWG) |
| Dibujos |
|---|
| 3-Dimensional STEP model (STP) Descargar (ZIP) |
| Product Drawing Drawing (DWG) |
Inicie sesión en su cuenta de Rockwell Automation para ver y descargar dibujos técnicos.
Registrarse
Documentos
|
Link to Connection Diagrams
General
-- |
|
Link to Online Catalog
General
-- |
|
Link to Application and Wiring Diagram Brochure
General
SAFETY-WD001 |
|
Product Cutsheet
General
-- |
|
Link to Application Examples Brochure
General
SAFETY-WD001 |
|
440r-in042_-mu-p
Installation Instructions
440R-IN042 |
|
440r-um013_-en-p
User Manual
440R-UM013 |
| Tipo | Recurso | Publicación |
|---|---|---|
| General | Link to Connection Diagrams | -- |
| General | Link to Online Catalog | -- |
| General | Link to Application and Wiring Diagram Brochure | SAFETY-WD001 |
| General | Product Cutsheet | -- |
| General | Link to Application Examples Brochure | SAFETY-WD001 |
| Installation Instructions | 440r-in042_-mu-p | 440R-IN042 |
| User Manual | 440r-um013_-en-p | 440R-UM013 |
¿Busca más documentación?
Encuentre documentación técnica seleccionada para este producto en el Centro de Documentación Técnica o busque en nuestra biblioteca de literatura.
Visite el Centro de Documentación Técnica
Busque en la biblioteca de literatura
Certificaciones
- China CCC
- Korean KC
- Kosha Approval
This product was certified with the above certifications as of 2025-09-09. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Productos alternativos
Notas técnicas
¿Busca más notas técnicas?
Encuentre preguntas y respuestas de los expertos técnicos de Rockwell Automation para este producto en nuestra base de conocimientos.
Buscar en la Base de Conocimientos
Loading