Especificaciones técnicas
General
Electrical
Construction
Mechanical
Environmental
Dibujos
Documentos
Certificaciones
Accesorios
Productos alternativos
Notas técnicas
Coil Code
110V 50 Hz / 120V 60 Hz.
Maximum Ampere Rating
12 A
Sub Brand
IEC
Voltage type for actuating
AC
Rated control supply voltage at AC 50 Hz
110 V
Rated control supply voltage at AC 60 Hz
120 V
Current (Ie), max
97 A
Switching frequency, max
250 ops/h
Main current circuit resistance
2.7 mohm
Cross section per UL/CSA
16
Rated operational current for contactor at elevator duty (UL/CSA)
9.6A @ 230V
Rated operational power for contactor at elevator duty (UL/CSA)
7.5Hp @ 575V
Rated isolation voltage (Ui)
690V @ IEC
Rated voltage (Ue)
690V @ AC, 50/60 Hz
Rated operational power for contactor at wye-delta
7.5Hp @ 230V, 60 Hz
Rated filament current
16A @ 230/240V, AC-5b
Power dissipation
1.2 W @ 400V, AC-3, Ie
Coil terminal conductor cross section
1…4 mm² @ 2 conductor
Rated current (enclosed)
9.8A @ 115V, 1-phase per UL/CSA
Rated power (enclosed)
7.5Hp @ 460V, 3-phase per UL/CSA
Coil consumption pick-up (avg/peak)
14/22 W @ DC (electronic-EA)
General purpose current (enclosed)
25 A per UL/CSA
Capacitance, max
500 µF @ short-circuit current of 20 kA
Switching of low inductive loads
32A @ 440V, AC-7a per IEC 61095 (50 Hz)
Operating limits, pick-up
(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of motor load
14A @ 230V, AC-7b per IEC 61095 (50 Hz)
Short time withstand (Icw)
170A @ 10s, 60 °C
Coil consumption, hold-in
9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz
Coil consumption, pick-up
75VA @ 50 Hz, 60 Hz, 50/60 Hz
Operating time
15…30 ms @ AC closing delay
Total power dissipation
DC control (electronic): 2.9 W @ 400V, AC-3, Ie
Operating limits, dropout
(0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lamps
Gas discharge lA, open: 25A @ 40°C (104 °F), AC-5a
Switching of hermetically sealed cooling compressor motors
7A @ 690V, AC-8b (manual reset of overload release (50 Hz))
Coil insulation class
Class F per IEC 60085, UL Class 105
Rating for switching AC motors
3-poles: 7.5Hp @ 460V (AC-2, AC-3, AC-4), 3-phase (60 Hz)
BS88 fuses current rating
Type 2 (per IEC 60947-4-1): 25A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating
40A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
UL class CC and CSA HRCI-MISC fuses rating
20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
UL inverse-time circuit breaker
30 A @ 600Y/347V @ 25kA available fault current per UL 508 and CSA 22.2 No. 14
Rated operational current (Ie)
9.6A @ 230V, 3-phase per UL/CSA
Rated operational power (Pe)
7.5 kW @230V, Star-Delta starting (50 Hz)
DIN fuses (gG, gL) current rating
Type 2 (per IEC 60947-4-1): 35A @ 690V, 50 kA available fault current
UL class J and CSA HRCI-J fuses rating
20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformers
Apparent power: 9.4 kVA @ 500V, AC-6a 50 Hz (n = 30)
Switching of 3-phase Capacitors
Single capacitor: 8 kVAR @ 690V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH)
Switching of DC loads
3-Poles in series: 6A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
Contacts
3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block
Function
Reversing contactor
Rated impulse voltage withstand (Uimp)
6 kV
Conventional coil type
Yes
Electronic-EI coil type
Yes
Rated coil frequency
AC 50/60 Hz, DC
Width
117 mm
Height
80.77 mm
Depth
104.48 mm
Options
Empty
Optional overload relays
Electronic or bimetallic
Optional accessories
Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches
Features
Panel mounting or mounting on 35 mm DIN rail, AC or DC coil control, Reversible coil terminals (line or load side), Common accessories, Made of environmentally friendly materials
Recommended torque
9 in-lb
Vibration resistance
IEC 60068-2-6
Shock resistance
IEC 60068-2-27
Coil termination
Line side connection
Conductor cross section
Main contacts, 2 conductor: 1…4 mm²
Lifespan
Mechanical DC control: 13000000 ops
Weight
0.93 kg (2.05 lbs) reverse @ DC (electronic-EW, EY, ED, EA)
Type of electrical connection of main circuit
Screw connection
Auxiliary contacts
1 NO, 1 NC
Altitude of installation site, max
2000 m (NN), per IEC60947-1
Protection against accidental contact
Finger-and back-of-hand proof per VDE0106, part 100
Ambient temperature
Storage: -55...80 (-67...176)
Protection class auxiliary contact
IP2X
Inicie sesión en su cuenta de Rockwell Automation para ver y descargar dibujos técnicos.
Registrarse
Tipo Recurso Publicación
General Product Cutsheet --
Technical Data 100-td013_-en-p 100-TD013
¿Busca más documentación?
Encuentre documentación técnica seleccionada para este producto en el Centro de Documentación Técnica o busque en nuestra biblioteca de literatura.
Busque en la biblioteca de literatura
IECEE Scheme
  • IECEE Scheme
  • SUVA LVD Type Approval

This product was certified with the above certifications as of 2025-12-23. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Ítems por página:
1-1 de 1
Ítems por página:
1-1 de 1
¿Busca más notas técnicas?
Encuentre preguntas y respuestas de los expertos técnicos de Rockwell Automation para este producto en nuestra base de conocimientos.
Buscar en la Base de Conocimientos
Especificaciones técnicas
Coil Code
110V 50 Hz / 120V 60 Hz.
Maximum Ampere Rating
12 A
Sub Brand
IEC
Voltage type for actuating
AC
Rated control supply voltage at AC 50 Hz
110 V
Rated control supply voltage at AC 60 Hz
120 V
Current (Ie), max
97 A
Switching frequency, max
250 ops/h
Main current circuit resistance
2.7 mohm
Cross section per UL/CSA
16
Rated operational current for contactor at elevator duty (UL/CSA)
9.6A @ 230V
Rated operational power for contactor at elevator duty (UL/CSA)
7.5Hp @ 575V
Rated isolation voltage (Ui)
690V @ IEC
Rated voltage (Ue)
690V @ AC, 50/60 Hz
Rated operational power for contactor at wye-delta
7.5Hp @ 230V, 60 Hz
Rated filament current
16A @ 230/240V, AC-5b
Power dissipation
1.2 W @ 400V, AC-3, Ie
Coil terminal conductor cross section
1…4 mm² @ 2 conductor
Rated current (enclosed)
9.8A @ 115V, 1-phase per UL/CSA
Rated power (enclosed)
7.5Hp @ 460V, 3-phase per UL/CSA
Coil consumption pick-up (avg/peak)
14/22 W @ DC (electronic-EA)
General purpose current (enclosed)
25 A per UL/CSA
Capacitance, max
500 µF @ short-circuit current of 20 kA
Switching of low inductive loads
32A @ 440V, AC-7a per IEC 61095 (50 Hz)
Operating limits, pick-up
(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of motor load
14A @ 230V, AC-7b per IEC 61095 (50 Hz)
Short time withstand (Icw)
170A @ 10s, 60 °C
Coil consumption, hold-in
9.5VA/2.7 W @ 50 Hz, 60 Hz, 50/60 Hz
Coil consumption, pick-up
75VA @ 50 Hz, 60 Hz, 50/60 Hz
Operating time
15…30 ms @ AC closing delay
Total power dissipation
DC control (electronic): 2.9 W @ 400V, AC-3, Ie
Operating limits, dropout
(0.3...0.6) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lamps
Gas discharge lA, open: 25A @ 40°C (104 °F), AC-5a
Switching of hermetically sealed cooling compressor motors
7A @ 690V, AC-8b (manual reset of overload release (50 Hz))
Coil insulation class
Class F per IEC 60085, UL Class 105
Rating for switching AC motors
3-poles: 7.5Hp @ 460V (AC-2, AC-3, AC-4), 3-phase (60 Hz)
BS88 fuses current rating
Type 2 (per IEC 60947-4-1): 25A @ 415V, 65 kA available fault current
UL class K5 and RK5 fuses rating
40A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
UL class CC and CSA HRCI-MISC fuses rating
20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
UL inverse-time circuit breaker
30 A @ 600Y/347V @ 25kA available fault current per UL 508 and CSA 22.2 No. 14
Rated operational current (Ie)
9.6A @ 230V, 3-phase per UL/CSA
Rated operational power (Pe)
7.5 kW @230V, Star-Delta starting (50 Hz)
DIN fuses (gG, gL) current rating
Type 2 (per IEC 60947-4-1): 35A @ 690V, 50 kA available fault current
UL class J and CSA HRCI-J fuses rating
20A @ 100kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformers
Apparent power: 9.4 kVA @ 500V, AC-6a 50 Hz (n = 30)
Switching of 3-phase Capacitors
Single capacitor: 8 kVAR @ 690V, AC-6b 50 Hz, 60 °C (Inductance of leads between capacitors in parallel: min. 6 µH)
Switching of DC loads
3-Poles in series: 6A @ 220V (Shunt-wound motors starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
Contacts
3 power poles with internal NO or NC auxiliary contact or 4 power poles (9...23 A), Optional front-or side mounted 1-2 or 4-pole external auxiliary contact block
Function
Reversing contactor
Rated impulse voltage withstand (Uimp)
6 kV
Conventional coil type
Yes
Electronic-EI coil type
Yes
Rated coil frequency
AC 50/60 Hz, DC
Width
117 mm
Height
80.77 mm
Depth
104.48 mm
Options
Empty
Optional overload relays
Electronic or bimetallic
Optional accessories
Front or side-mount auxiliary contacts, Surge suppressors, Electronic or pneumatic timers, Mechanical interlocks, Mechanical latches
Features
Panel mounting or mounting on 35 mm DIN rail, AC or DC coil control, Reversible coil terminals (line or load side), Common accessories, Made of environmentally friendly materials
Recommended torque
9 in-lb
Vibration resistance
IEC 60068-2-6
Shock resistance
IEC 60068-2-27
Coil termination
Line side connection
Conductor cross section
Main contacts, 2 conductor: 1…4 mm²
Lifespan
Mechanical DC control: 13000000 ops
Weight
0.93 kg (2.05 lbs) reverse @ DC (electronic-EW, EY, ED, EA)
Type of electrical connection of main circuit
Screw connection
Auxiliary contacts
1 NO, 1 NC
Altitude of installation site, max
2000 m (NN), per IEC60947-1
Protection against accidental contact
Finger-and back-of-hand proof per VDE0106, part 100
Ambient temperature
Storage: -55...80 (-67...176)
Protection class auxiliary contact
IP2X
Dibujos
Inicie sesión en su cuenta de Rockwell Automation para ver y descargar dibujos técnicos.
Registrarse
Documentos
Product Cutsheet General
--
100-td013_-en-p Technical Data
100-TD013
Tipo Recurso Publicación
General Product Cutsheet --
Technical Data 100-td013_-en-p 100-TD013
¿Busca más documentación?
Encuentre documentación técnica seleccionada para este producto en el Centro de Documentación Técnica o busque en nuestra biblioteca de literatura.
Busque en la biblioteca de literatura
Certificaciones
IECEE Scheme
  • IECEE Scheme
  • SUVA LVD Type Approval

This product was certified with the above certifications as of 2025-12-23. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Accesorios
Ítems por página:
1-1 de 1
Productos alternativos
Ítems por página:
1-1 de 1
Notas técnicas
¿Busca más notas técnicas?
Encuentre preguntas y respuestas de los expertos técnicos de Rockwell Automation para este producto en nuestra base de conocimientos.
Buscar en la Base de Conocimientos
Loading
Encuentre su distribuidor más cercano
Contact your distributor in {0}
Cambiar ubicación
EmailEmail
PhonePhone
Encuentre un socio
IEC 12 A Reversing Contactor
CloseClose
104-C12D22
Cerrar
Imprimir
Chevron LeftChevron Left
Allen-Bradley 104-C12D22 product image
Chevron LeftChevron Left
Allen-Bradley 104-C12D22 product image
Allen-Bradley 104-C12D22 product image
Teléfono:
Llamar
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Página principal de Rockwell Automation
  2. Chevron LeftChevron Left Productos
Actualice sus preferencias de cookies para continuar.
Esta función requiere cookies para mejorar su experiencia. Actualice sus preferencias para permitir estas cookies.:
  • Cookies de Redes Sociales
  • Cookies Funcionales
  • Cookies de Performance
  • Cookies de Marketing
  • Todas las cookies
Puede actualizar sus preferencias en cualquier momento. Para más información, vea nuestro {0} Política de Privacidad
CloseClose