View all NEMA Open/Enclosed Full Voltage Starters
505-CAD-XXX
Size 2 RVSG Starter
Serial #:
This product has not been verified. Please register your product to confirm authenticity.
Lifecycle status:
Active
Lifecycle status:
Active
Technical Specifications
General
Electrical
Contruction
Mechanical
Construction
Environmental
Documents
Accessories
Alternative Products
Technotes
| Enclosure Type |
NEMA 1 General Purpose,Type 1 - Enclosure Code "A"
|
|---|
| Voltage type for actuating |
AC
|
|---|---|
| With transformer |
False
|
| Suitable for emergency stop |
True
|
| External reset possible |
True
|
| With fuse |
False
|
| Rated control supply voltage at AC 60 Hz |
115 V
|
| Type of motor starter |
Reversing starter
|
| Continuous current rating |
45 A
|
| Service limit current rating |
52 A
|
| Circuit closing inrush current peak including offset, max |
483 A
|
| Load voltage |
200 to 575V
|
| Heat dissipation |
5.9 W (4...5 poles)
|
| Coil operating limits |
85 to 110 %
|
| Operating volt amperes burden |
Sealed: 38VA, 60 Hz coils (4...5 poles)
|
| Hp rating |
25Hp @ 575V load voltage, 3-phase
|
| Temperature compensated overload protection |
True
|
| Coordination class according to IEC 60947-4-3 |
Class 2
|
| Type of electrical connection of main circuit |
Screw connection
|
| Type of electrical connection for auxiliary- and control current circuit |
Screw connection
|
| Width |
12.99 mm
|
|---|---|
| Height |
22 mm
|
| Depth |
8.5 mm
|
| Degree of protection (NEMA) |
1
|
|---|---|
| Number of auxiliary contacts, max |
8
|
| Mechanical life operations |
1.0E7
|
| Operating time, drop-out |
13 ms
|
| Operating time, pick-up |
27 ms
|
| Enclosure type |
NEMA 1 general purpose
|
| Material housing |
Steel
|
|---|---|
| Required torque on power terminal wire clamps and pressure connectors or lugs |
45 in-lb
|
| Auxiliary contact material |
Silver
|
| Type of power terminal |
Pressure terminals
|
| Wire size |
For power terminals: 14...4 AWG
|
| Power contact material |
Silver alloy
|
| Requirements for sizing of wire |
All wire rated 167 °F (75 °C) or higher must be sized per the local electrical code for 167 °F (75 °C) wire
|
| NEMA size |
Size 2
|
|---|---|
| Operating position |
Vertical
|
| Altitude |
10000 ft before derating
|
| Overload relay |
Provision for mounting an overload relay (field installation)
|
| Corrosion-resistance |
All metal parts are treated for corrosion-resistance
|
| General | Publication |
|---|---|
| Renewal Parts for Overload Relay Reset Button | -- |
| Repair Parts for Enclosure | -- |
| Repair Parts for Misc. Items | -- |
| Repair Parts List | -- |
| Product Cutsheet | -- |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Items Per Page:
Items Per Page:
| Technotes |
|---|
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
| Enclosure Type |
NEMA 1 General Purpose,Type 1 - Enclosure Code "A"
|
|---|
| Voltage type for actuating |
AC
|
|---|---|
| With transformer |
False
|
| Suitable for emergency stop |
True
|
| External reset possible |
True
|
| With fuse |
False
|
| Rated control supply voltage at AC 60 Hz |
115 V
|
| Type of motor starter |
Reversing starter
|
| Continuous current rating |
45 A
|
| Service limit current rating |
52 A
|
| Circuit closing inrush current peak including offset, max |
483 A
|
| Load voltage |
200 to 575V
|
| Heat dissipation |
5.9 W (4...5 poles)
|
| Coil operating limits |
85 to 110 %
|
| Operating volt amperes burden |
Sealed: 38VA, 60 Hz coils (4...5 poles)
|
| Hp rating |
25Hp @ 575V load voltage, 3-phase
|
| Temperature compensated overload protection |
True
|
| Coordination class according to IEC 60947-4-3 |
Class 2
|
| Type of electrical connection of main circuit |
Screw connection
|
| Type of electrical connection for auxiliary- and control current circuit |
Screw connection
|
| Width |
12.99 mm
|
|---|---|
| Height |
22 mm
|
| Depth |
8.5 mm
|
| Degree of protection (NEMA) |
1
|
|---|---|
| Number of auxiliary contacts, max |
8
|
| Mechanical life operations |
1.0E7
|
| Operating time, drop-out |
13 ms
|
| Operating time, pick-up |
27 ms
|
| Enclosure type |
NEMA 1 general purpose
|
| Material housing |
Steel
|
|---|---|
| Required torque on power terminal wire clamps and pressure connectors or lugs |
45 in-lb
|
| Auxiliary contact material |
Silver
|
| Type of power terminal |
Pressure terminals
|
| Wire size |
For power terminals: 14...4 AWG
|
| Power contact material |
Silver alloy
|
| Requirements for sizing of wire |
All wire rated 167 °F (75 °C) or higher must be sized per the local electrical code for 167 °F (75 °C) wire
|
| NEMA size |
Size 2
|
|---|---|
| Operating position |
Vertical
|
| Altitude |
10000 ft before derating
|
| Overload relay |
Provision for mounting an overload relay (field installation)
|
| Corrosion-resistance |
All metal parts are treated for corrosion-resistance
|
Documents
|
Renewal Parts for Overload Relay Reset Button
General
-- |
|
Repair Parts for Enclosure
General
-- |
|
Repair Parts for Misc. Items
General
-- |
|
Repair Parts List
General
-- |
|
Product Cutsheet
General
-- |
| General | Publication |
|---|---|
| Renewal Parts for Overload Relay Reset Button | -- |
| Repair Parts for Enclosure | -- |
| Repair Parts for Misc. Items | -- |
| Repair Parts List | -- |
| Product Cutsheet | -- |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Accessories
Items Per Page:
Alternative Products
Items Per Page:
Technotes
| Technotes |
|---|
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Size 2 RVSG Starter
505-CAD-XXX
Close
Print
Copyright ©2026 Rockwell Automation, Inc.