1783-MX08F
Stratix 8000 Fiber 8 Port Exp. Module
Rockwell Automation announces that as of November 30, 2020, the Stratix 8000 Fiber 8 Port Exp. Module will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
Discontinued Date:
November 30, 2020
Replacement Category:
Functional Replacement
Product at a glance
Rockwell Automation announces that as of November 30, 2020, the Stratix 8000 Fiber 8 Port Exp. Module will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
Discontinued Date:
November 30, 2020
Replacement Category:
Functional Replacement
Product at a glance
| Network |
Ethernet
|
|---|
| Ethernet |
False
|
|---|---|
| Fast Ethernet |
True
|
| Gigabit Ethernet |
False
|
| Power consumption, maximum |
10.1 W
|
| Power dissipation |
10.1 W
|
| Backplane power, maximum |
3.3V DC @ 3.6A
|
| 10 Gigabit Ethernet |
False
|
| Connector type |
IEC 61754-20 LC connector
|
| Connecting mode |
Full duplex
|
| Ethernet data rate |
100 Mbps
|
| Number of 100 Base-F fiber-optic Ethernet ports |
8
|
| Optical cable length, graded index multimode fiber, maximum |
2000 m
|
| Optical link budget with 50/125 μm multimode cable |
4 dBb
|
| Optical link budget with 62.5/125 μm multimode cable |
8 dBb
|
| Optical wavelength |
1310 nm
|
| ESD immunity, IEC 61000-4-2, air discharges |
15 kV
|
|---|---|
| ESD immunity, IEC 61000-4-2, contact discharges |
8 kV
|
| Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
20 g
|
| Housing base material |
Open-style
|
| Nominal position |
T4
|
| Selectable start times |
T4
|
| Temperature, surrounding air, maximum |
60 °C
|
| Emissions, CISPR11 (IEC 61000-6-4) |
Group 1, class A
|
| Magnetic field immunity, IEC 61000-4-8, long duration at 50 and 60 Hz (A/m) |
30
|
| Magnetic field immunity, IEC 61000-4-8, short duration at 50 and 60 Hz (A/m) |
300
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 1000 - 2700 MHz |
10 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 1000 MHz |
20 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz |
10 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz |
10 kg/km
|
| Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing |
5 %
|
| Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
30 g
|
| Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat) |
-40 °C
|
| Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) |
-40 °C
|
| Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock) |
-40 °C
|
| Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat) |
-40 °C
|
| Vibration, IEC 60068-2-6 (test Fc, operating) at 10 - 500 Hz |
2 g
|
| Width |
9.81 cm
|
|---|---|
| Height |
14.8 cm
|
| Depth |
11.75 cm
|
| Type | Resource | Publication |
|---|---|---|
| Technical Data | 1783-td001_-en-p | 1783-TD001 |
| User Manual | 1783-um003_-en-p | 1783-UM003 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
- MOROCCO DOC
This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
| Network |
Ethernet
|
|---|
| Ethernet |
False
|
|---|---|
| Fast Ethernet |
True
|
| Gigabit Ethernet |
False
|
| Power consumption, maximum |
10.1 W
|
| Power dissipation |
10.1 W
|
| Backplane power, maximum |
3.3V DC @ 3.6A
|
| 10 Gigabit Ethernet |
False
|
| Connector type |
IEC 61754-20 LC connector
|
| Connecting mode |
Full duplex
|
| Ethernet data rate |
100 Mbps
|
| Number of 100 Base-F fiber-optic Ethernet ports |
8
|
| Optical cable length, graded index multimode fiber, maximum |
2000 m
|
| Optical link budget with 50/125 μm multimode cable |
4 dBb
|
| Optical link budget with 62.5/125 μm multimode cable |
8 dBb
|
| Optical wavelength |
1310 nm
|
| ESD immunity, IEC 61000-4-2, air discharges |
15 kV
|
|---|---|
| ESD immunity, IEC 61000-4-2, contact discharges |
8 kV
|
| Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
20 g
|
| Housing base material |
Open-style
|
| Nominal position |
T4
|
| Selectable start times |
T4
|
| Temperature, surrounding air, maximum |
60 °C
|
| Emissions, CISPR11 (IEC 61000-6-4) |
Group 1, class A
|
| Magnetic field immunity, IEC 61000-4-8, long duration at 50 and 60 Hz (A/m) |
30
|
| Magnetic field immunity, IEC 61000-4-8, short duration at 50 and 60 Hz (A/m) |
300
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 1000 - 2700 MHz |
10 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 1000 MHz |
20 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz |
10 kg/km
|
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz |
10 kg/km
|
| Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing |
5 %
|
| Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) |
30 g
|
| Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock) |
-40 °C
|
| Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat) |
-40 °C
|
| Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) |
-40 °C
|
| Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock) |
-40 °C
|
| Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat) |
-40 °C
|
| Vibration, IEC 60068-2-6 (test Fc, operating) at 10 - 500 Hz |
2 g
|
| Width |
9.81 cm
|
|---|---|
| Height |
14.8 cm
|
| Depth |
11.75 cm
|
Documents
|
1783-td001_-en-p
Technical Data
1783-TD001 |
|
1783-um003_-en-p
User Manual
1783-UM003 |
| Type | Resource | Publication |
|---|---|---|
| Technical Data | 1783-td001_-en-p | 1783-TD001 |
| User Manual | 1783-um003_-en-p | 1783-UM003 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Certifications
- MOROCCO DOC
This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Alternative Products
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading
Copyright ©2025 Rockwell Automation, Inc.