1783-ms10t
Stratix 8000 10 Port Managed Switch
Rockwell Automation announces that as of November 30, 2020, the Stratix 8000 10 Port Managed Switch will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
Discontinued Date:
November 30, 2020
Replacement Category:
Functional Replacement
Product at a glance
Rockwell Automation announces that as of November 30, 2020, the Stratix 8000 10 Port Managed Switch will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
Discontinued Date:
November 30, 2020
Replacement Category:
Functional Replacement
Product at a glance
| Network | Ethernet |
|---|---|
| Port | 10 |
| Width | 15.3 cm |
|---|---|
| Height | 14.8 cm |
| Depth | 11.75 cm |
| Screw torque, power and alarm terminals | 0.23 nm |
| Layer 2 | True |
|---|---|
| Layer 3 | False |
| Manageable | True |
| Power dissipation | 15.7 W |
| Power consumption, maximum (expansion module power not included) | 15.7 W |
| Total number of ports | 10 |
| Wire size, ethernet connection | RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702 |
| Ethernet | True |
| Protection type—Electronic S (short time trip units) | Panel mount |
| Alarm relay, CL 2/SELV at 30 V DC, maximum | 1 A |
| Inrush current, maximum | 2 A |
| Isolation voltage (continuous), basic insulation type, power to ground, power to network channels, and power to alarm | 75 V |
| Maximum insulation, DC power and alarm connections | 1.2 mm |
| Oscillatory surge withstand IEEE C37.90.1 | 2.5 kV |
| Switch input, CL 2/SELV at 18 - 60 V DC, maximum | 2 A |
| Wire size, DC power and alarm connections, solid or stranded copper wire rated at 90 °C or greater | 0.5 mm² |
| Wire size, ground connection, solid or stranded copper wire rated at 75 °C or greater | 3.3 mm² |
| Wiring category on alarm ports | 2 |
| Wiring category on Ethernet ports | 2 |
| Wiring category on power ports | 2 |
| Degree of protection (IP) | IP20 |
|---|---|
| Housing base material | Open-style |
| Nominal position | T4 |
| Temperature, surrounding air, maximum | 60 °C |
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on alarm ports | ±2 |
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on Ethernet ports | ±2 |
| Emissions, CISPR11 (IEC 61000-6-4) | Class A |
| ESD immunity, IEC 61000-4-2, air discharges | 15 kV |
| ESD immunity, IEC 61000-4-2, contact discharges | 8 kV |
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 1000 - 2700 MHz | 10 kg/km |
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz | 10 kg/km |
| Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) | 30 g |
| Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) | 20 g |
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports | ±2 |
| Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) | -40 °C |
| Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock) | -40 °C |
| Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat) | -40 °C |
| Selectable start times | T4 |
| Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms) | 10 V |
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on alarm ports | ±4 |
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on Ethernet ports | ±4 |
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on power ports | ±4 |
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on power ports | ±2 |
| Magnetic field immunity, IEC 61000-4-8, long duration at 50 and 60 Hz (A/m) | 30 |
| Magnetic field immunity, IEC 61000-4-8, short duration at 50 and 60 Hz (A/m) | 300 |
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 1000 MHz | 20 kg/km |
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz | 10 kg/km |
| Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing | 5 % |
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on alarm ports | ±2 |
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on power ports | ±2 |
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on alarm ports | ±1 |
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on power ports | ±1 |
| Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold) | -40 °C |
| Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock) | -40 °C |
| Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat) | -40 °C |
| Vibration, IEC 60068-2-6 (test Fc, operating) at 10 - 500 Hz | 2 g |
| Voltage variation IEC 61000-4-29, interruption on DC supply ports | 10 ms |
| Type | Resource | Publication |
|---|---|---|
| Application Techniques | APPLICATION_TECHNIQUES_enet-at007_-en-p | ENET-AT007 |
| Application Techniques | APPLICATION_TECHNIQUES_enet-at006_-en-p | ENET-AT006 |
| Installation Instructions | 1783-in016_-en-p | 1783-IN016 |
| Profile | PROFILE_migrat-pp043_-en-p | MIGRAT-PP043 |
| Reference Manual | REFERENCE_MANUAL_enet-rm002_-en-p | ENET-RM002 |
| Technical Data | 1783-td002_-en-p | 1783-TD002 |
| User Manual | 1783-um003_-en-p | 1783-UM003 |
| User Manual | USER_MANUAL_1783-um007_-en-p | 1783-UM007 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Available Downloads
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v14.01.05
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v15.01.07
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v15.03.02
- AOP for Stratix 5700, 8000, 8300, 5400, 5410, 2500 v17.01.05
- AOP for Stratix 5700, 8000, 8300, 5400, 5410, 2500 v18.01.06
- AOP for Stratix 5700, 8000, 8300, 5400, 5410, 2500 v19.01.07
- AOP for Stratix 5700, 8000, 8300, 5400, 5410, 2500 and 5800 v19.01.18
- EDS files for 1783-MS10T (multi)
- EDS files for Stratix Family (multi)
- AOP - Add On Profiles for 1783 and all Stratix v22.01.01
- MOROCCO DOC
This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
| Network | Ethernet |
|---|---|
| Port | 10 |
| Width | 15.3 cm |
|---|---|
| Height | 14.8 cm |
| Depth | 11.75 cm |
| Screw torque, power and alarm terminals | 0.23 nm |
| Layer 2 | True |
|---|---|
| Layer 3 | False |
| Manageable | True |
| Power dissipation | 15.7 W |
| Power consumption, maximum (expansion module power not included) | 15.7 W |
| Total number of ports | 10 |
| Wire size, ethernet connection | RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702 |
| Ethernet | True |
| Protection type—Electronic S (short time trip units) | Panel mount |
| Alarm relay, CL 2/SELV at 30 V DC, maximum | 1 A |
| Inrush current, maximum | 2 A |
| Isolation voltage (continuous), basic insulation type, power to ground, power to network channels, and power to alarm | 75 V |
| Maximum insulation, DC power and alarm connections | 1.2 mm |
| Oscillatory surge withstand IEEE C37.90.1 | 2.5 kV |
| Switch input, CL 2/SELV at 18 - 60 V DC, maximum | 2 A |
| Wire size, DC power and alarm connections, solid or stranded copper wire rated at 90 °C or greater | 0.5 mm² |
| Wire size, ground connection, solid or stranded copper wire rated at 75 °C or greater | 3.3 mm² |
| Wiring category on alarm ports | 2 |
| Wiring category on Ethernet ports | 2 |
| Wiring category on power ports | 2 |
| Degree of protection (IP) | IP20 |
|---|---|
| Housing base material | Open-style |
| Nominal position | T4 |
| Temperature, surrounding air, maximum | 60 °C |
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on alarm ports | ±2 |
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on Ethernet ports | ±2 |
| Emissions, CISPR11 (IEC 61000-6-4) | Class A |
| ESD immunity, IEC 61000-4-2, air discharges | 15 kV |
| ESD immunity, IEC 61000-4-2, contact discharges | 8 kV |
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 1000 - 2700 MHz | 10 kg/km |
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz | 10 kg/km |
| Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) | 30 g |
| Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) | 20 g |
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports | ±2 |
| Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) | -40 °C |
| Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock) | -40 °C |
| Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat) | -40 °C |
| Selectable start times | T4 |
| Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms) | 10 V |
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on alarm ports | ±4 |
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on Ethernet ports | ±4 |
| EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on power ports | ±4 |
| EFT/B immunity for IEC 61000-4-4 at 5 kHz on power ports | ±2 |
| Magnetic field immunity, IEC 61000-4-8, long duration at 50 and 60 Hz (A/m) | 30 |
| Magnetic field immunity, IEC 61000-4-8, short duration at 50 and 60 Hz (A/m) | 300 |
| Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 1000 MHz | 20 kg/km |
| Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz | 10 kg/km |
| Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing | 5 % |
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on alarm ports | ±2 |
| Surge transient immunity, IEC 61000-4-5, line-earth (CM) on power ports | ±2 |
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on alarm ports | ±1 |
| Surge transient immunity, IEC 61000-4-5, line-line (DM) on power ports | ±1 |
| Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold) | -40 °C |
| Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock) | -40 °C |
| Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat) | -40 °C |
| Vibration, IEC 60068-2-6 (test Fc, operating) at 10 - 500 Hz | 2 g |
| Voltage variation IEC 61000-4-29, interruption on DC supply ports | 10 ms |
Documents
|
APPLICATION_TECHNIQUES_enet-at007_-en-p
Application Techniques
ENET-AT007 |
|
APPLICATION_TECHNIQUES_enet-at006_-en-p
Application Techniques
ENET-AT006 |
|
1783-in016_-en-p
Installation Instructions
1783-IN016 |
|
PROFILE_migrat-pp043_-en-p
Profile
MIGRAT-PP043 |
|
REFERENCE_MANUAL_enet-rm002_-en-p
Reference Manual
ENET-RM002 |
|
1783-td002_-en-p
Technical Data
1783-TD002 |
|
1783-um003_-en-p
User Manual
1783-UM003 |
|
USER_MANUAL_1783-um007_-en-p
User Manual
1783-UM007 |
| Type | Resource | Publication |
|---|---|---|
| Application Techniques | APPLICATION_TECHNIQUES_enet-at007_-en-p | ENET-AT007 |
| Application Techniques | APPLICATION_TECHNIQUES_enet-at006_-en-p | ENET-AT006 |
| Installation Instructions | 1783-in016_-en-p | 1783-IN016 |
| Profile | PROFILE_migrat-pp043_-en-p | MIGRAT-PP043 |
| Reference Manual | REFERENCE_MANUAL_enet-rm002_-en-p | ENET-RM002 |
| Technical Data | 1783-td002_-en-p | 1783-TD002 |
| User Manual | 1783-um003_-en-p | 1783-UM003 |
| User Manual | USER_MANUAL_1783-um007_-en-p | 1783-UM007 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Downloads
Available Downloads
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v14.01.05
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v15.01.07
- AOP for Stratix 5400/5410/5700/8000/8300/2500 Switches v15.03.02
- AOP for Stratix 5700, 8000, 8300, 5400, 5410, 2500 v17.01.05
- AOP for Stratix 5700, 8000, 8300, 5400, 5410, 2500 v18.01.06
- AOP for Stratix 5700, 8000, 8300, 5400, 5410, 2500 v19.01.07
- AOP for Stratix 5700, 8000, 8300, 5400, 5410, 2500 and 5800 v19.01.18
- EDS files for 1783-MS10T (multi)
- EDS files for Stratix Family (multi)
- AOP - Add On Profiles for 1783 and all Stratix v22.01.01
Certifications
- MOROCCO DOC
This product was certified with the above certifications as of 2025-09-08. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading
Copyright ©2025 Rockwell Automation, Inc.