Height
118mm
Interface
2 Ethernet RJ45 Category 5
Isolation
50V (continuous), basic insulation type
Number of HW-interfaces industrial Ethernet
2
Suitable for safety functions
False
With optical interface
False
Supporting protocol for TCP/IP
True
Supporting protocol for DeviceNet
False
Supporting protocol for other bus systems
False
Redundancy
False
IO link master
False
Supporting protocol for DeviceNet Safety
False
Supporting protocol for EtherNet/IP
True
Type of data transmission
Other
TCP/IP communication connections
96
Logix communication connections
128
Enclosure type rating
None (open-style)
Current draw
500mA @ 5.2V DC
Ports
2 Ethernet RJ45 Category 5
Wire category
1 - on communication ports
Wire size
Ethernet connections: RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702.
Isolation voltage
50V (continuous), basic insulation type, Tested at 710V DC @ 60s
Supporting protocol for LON
False
Supporting protocol for ASI
False
Supporting protocol for PROFIBUS
False
Supporting protocol for CAN
False
Supporting protocol for INTERBUS
False
Supporting protocol for KNX
False
Supporting protocol for Modbus
False
Supporting protocol for Data-Highway
False
Supporting protocol for SUCONET
False
With potential separation
False
Supporting protocol for SERCOS
False
Supporting protocol for INTERBUS-Safety
False
Radio standard Bluetooth
False
Radio standard Wi-Fi 802.11
False
Supporting protocol for AS-Interface Safety at Work
False
Supporting protocol for Foundation Fieldbus
False
Supporting protocol for PROFINET CBA
False
Supporting protocol for PROFINET IO
False
Supporting protocol for PROFIsafe
False
Supporting protocol for SafetyBUS p
False
Radio standard GPRS
False
Radio standard GSM
False
Radio standard UMTS
False
Slot width
1
EtherNet/IP communication rate
10/100 Mbps
Width
50 mm
Height
118 mm
Depth
87 mm
Weight, approx
0.28 kg
Module location
DIN rail or panel mount
Mounting screw torque
1.16 Nm (10 in-lb) - use M4 or #8 screws
Surrounding air temperature, max
60 °C
Emissions
CISPR 11 (IEC 61000-6-4): Class A
Vibration
2 G @ 10...500 Hz
ESD immunity
6 kV contact discharges, 8 kV air discharges
EFT/B immunity
±3kV @ 5kHz on communications ports
Relative humidity
5...95% noncondensing
Shock
Operating: 15 G
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity
±2 kV line-earth (CM) on communication ports
Nonoperating temperature
-40 to 85 °C
Operating temperature
0 to 60 °C
Radiated RF immunity
10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
North American temperature code
T3C
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Type Resource Publication
General Product Cutsheet --
General Selection Guide 1769-SG001
Technical Data 1769-td005_-en-p 1769-TD005
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Search the Literature Library
Available Downloads
  • Firmware for 1769-AENTR v1.003
See All Downloads
UKCA DOC
  • UKCA DOC
  • MOROCCO DOC

This product was certified with the above certifications as of 2025-10-15. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Items Per Page:
1-1 of 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
Height
118mm
Interface
2 Ethernet RJ45 Category 5
Isolation
50V (continuous), basic insulation type
Number of HW-interfaces industrial Ethernet
2
Suitable for safety functions
False
With optical interface
False
Supporting protocol for TCP/IP
True
Supporting protocol for DeviceNet
False
Supporting protocol for other bus systems
False
Redundancy
False
IO link master
False
Supporting protocol for DeviceNet Safety
False
Supporting protocol for EtherNet/IP
True
Type of data transmission
Other
TCP/IP communication connections
96
Logix communication connections
128
Enclosure type rating
None (open-style)
Current draw
500mA @ 5.2V DC
Ports
2 Ethernet RJ45 Category 5
Wire category
1 - on communication ports
Wire size
Ethernet connections: RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702.
Isolation voltage
50V (continuous), basic insulation type, Tested at 710V DC @ 60s
Supporting protocol for LON
False
Supporting protocol for ASI
False
Supporting protocol for PROFIBUS
False
Supporting protocol for CAN
False
Supporting protocol for INTERBUS
False
Supporting protocol for KNX
False
Supporting protocol for Modbus
False
Supporting protocol for Data-Highway
False
Supporting protocol for SUCONET
False
With potential separation
False
Supporting protocol for SERCOS
False
Supporting protocol for INTERBUS-Safety
False
Radio standard Bluetooth
False
Radio standard Wi-Fi 802.11
False
Supporting protocol for AS-Interface Safety at Work
False
Supporting protocol for Foundation Fieldbus
False
Supporting protocol for PROFINET CBA
False
Supporting protocol for PROFINET IO
False
Supporting protocol for PROFIsafe
False
Supporting protocol for SafetyBUS p
False
Radio standard GPRS
False
Radio standard GSM
False
Radio standard UMTS
False
Slot width
1
EtherNet/IP communication rate
10/100 Mbps
Width
50 mm
Height
118 mm
Depth
87 mm
Weight, approx
0.28 kg
Module location
DIN rail or panel mount
Mounting screw torque
1.16 Nm (10 in-lb) - use M4 or #8 screws
Surrounding air temperature, max
60 °C
Emissions
CISPR 11 (IEC 61000-6-4): Class A
Vibration
2 G @ 10...500 Hz
ESD immunity
6 kV contact discharges, 8 kV air discharges
EFT/B immunity
±3kV @ 5kHz on communications ports
Relative humidity
5...95% noncondensing
Shock
Operating: 15 G
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity
±2 kV line-earth (CM) on communication ports
Nonoperating temperature
-40 to 85 °C
Operating temperature
0 to 60 °C
Radiated RF immunity
10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
North American temperature code
T3C
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Documents
Product Cutsheet General
--
Selection Guide General
1769-SG001
1769-td005_-en-p Technical Data
1769-TD005
Type Resource Publication
General Product Cutsheet --
General Selection Guide 1769-SG001
Technical Data 1769-td005_-en-p 1769-TD005
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Search the Literature Library
Downloads
Available Downloads
  • Firmware for 1769-AENTR v1.003
See All Downloads
Certifications
UKCA DOC
  • UKCA DOC
  • MOROCCO DOC

This product was certified with the above certifications as of 2025-10-15. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Alternative Products
Items Per Page:
1-1 of 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading
Find your nearest distributor
Contact your distributor in {0}
Change location
EmailEmail
PhonePhone
Find a partner
1769 Ethernet/IP Adapter
CloseClose
1769-aentr
Close
Print
Allen-Bradley 1769-aentr product image
Phone:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
Sign in to your Rockwell Automation account to submit a repair documentation request.
Sign In
Request repair documentation
All fields with * are required for processing your request.
This field is required
This field is required
This field is required
This field is required
This field is required
Documentation of liability insurance is required for anyone who is requesting documentation for product repairs.
UploadUpload
Please upload documentation of liability insurance.*
1 file selected
CloseClose
File size is too large. Must be less than 5 MB.
Accepted file types: zip, pdf; Maximum size: 5 MB.
Right to Repair Terms and Conditions
Rockwell Automation is making, parts, and service documentation available at your request in compliance with applicable right to repair laws and regulations. By signing below, you are agreeing to the following terms and conditions of your purchase of Rockwell Automation genuine repair parts for repair of a Rockwell Automation product. As used below, “Self Service Repair Parts” means genuine Rockwell Automation parts (components of Rockwell Automation products) purchased from Rockwell Automation for installation in a Rockwell Automation product as part of a Self Service Repair. Self Service Repair Parts may be new or previously used genuine Rockwell Automation parts that have been tested and passed Rockwell Automation functional requirements. “Self Service Repair Tools” means equipment and related materials purchased for the purpose of performing repairs.
Your request has been successfully submitted.
Please allow up to 5 business days to receive a response to your inquiry.
  1. Chevron LeftChevron Left Rockwell Automation Home
  2. Chevron LeftChevron Left Products
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose