MicroLogix 8 Point Digital Input Module
| Unique Product Identifier |
1762-ia8
|
|---|---|
| UPC |
612598207183
|
| Estimated Lead Time |
5 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Malaysia
|
| EU Importer Address |
Rockwell Automation N.V |
| EU Authorized Representative Address |
Rockwell Automation N.V |
The information provided by Rockwell Automation on www.rockwellautomation.com (the “Site”) is for demonstration purposes only and may be incomplete or inaccurate. All information is provided “as is”, and Rockwell Automation makes no representations or warranties of any kind, express or implied, regarding the accuracy, adequacy, validity, reliability, or completeness of any information on the Site. Use of this information is at your own risk.
| Class |
Progmable Logic Controller
|
|---|---|
| Depth |
87
|
| digital input modules |
8 Point 120V AC Input Module
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Digital
|
| Number Of Channels |
8 Point
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| Number of digital inputs |
8
|
|---|---|
| Time delay at signal exchange |
20 ms
|
| Suitable for safety functions |
False
|
| Digital inputs configurable |
False
|
| Digital outputs configurable |
False
|
| Type of voltage (input voltage) |
AC
|
| Type of electric connection |
Screw connection
|
| Nominal Impedance |
12 kΩ @ 50 Hz
|
| Number of commons |
1
|
| Heat dissipation, max |
2 W
|
| Bus current draw, max |
50mA @ 5V DC (0.25 W)
|
| ON-state current, max |
16.0mA @ 132V AC, 63 Hz
|
| Inrush current, max |
250 mA
|
| Power supply distance rating |
6 (the module may not be more than 6 modules away from the system power supply)
|
| On-state current, nom |
12.0mA @ 120V AC, 60 Hz
|
| Isolated groups |
Group 1: inputs 0...7 (internally connected commons)
|
| Input group to backplane isolation |
Verified by one of the following dielectric tests: 1517V AC @ 1s or 2145V DC @ 1s. 132V AC working voltage (IEC Class 2 reinforced insulation)
|
| Redundancy |
False
|
| Short-circuit protection, outputs available |
False
|
| Width |
40.4 mm
|
|---|---|
| Height |
90 mm
|
| Depth |
87 mm
|
| Weight |
209 g
|
| Shock |
Operating: 30G panel mounted, 3 pulses per axis, Relay ops: 7G
|
| Vibration |
Operating: 10...500 Hz, 5 G, 0.015 in. maximum, peak-to-peak, 2 hr each axis, Relay ops: 1.5 G
|
| IEC input compatibility |
Type 1+
|
|---|
| IEC input compatibility |
Type 1+
|
|---|
| Signal delay |
On delay: 20.0 ms
|
|---|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
|---|---|
| Conducted RF immunity |
IEC 1000-4-6: 10V @ 0.15...80MHz
|
| EFT/B immunity |
IEC1000-4-4: 2kV @ 5kHz
|
| Hazardous environment class |
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
| Operating temperature |
-20 to 65 °C
|
| Surge transient immunity |
IEC1000-4-5: 2 kV common mode, 1kV differential mode
|
| Radiated RF immunity |
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Altitude |
2000 m
|
| Storage temperature, min |
-40 °C
|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Operating humidity |
5...95% noncondensing
|
| Drawings | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
| General | Publication |
|---|---|
| Selection Guide | 1761-SG001 |
| Product Cutsheet | -- |
- UL Listed Hazardous
This product was certified with the above certifications as of {}. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
| Technotes |
|---|
Overview
| Unique Product Identifier |
1762-ia8
|
|---|---|
| UPC |
612598207183
|
| Estimated Lead Time |
5 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Malaysia
|
| EU Importer Address |
Rockwell Automation N.V |
| EU Authorized Representative Address |
Rockwell Automation N.V |
The information provided by Rockwell Automation on www.rockwellautomation.com (the “Site”) is for demonstration purposes only and may be incomplete or inaccurate. All information is provided “as is”, and Rockwell Automation makes no representations or warranties of any kind, express or implied, regarding the accuracy, adequacy, validity, reliability, or completeness of any information on the Site. Use of this information is at your own risk.
Technical Specifications
| Class |
Progmable Logic Controller
|
|---|---|
| Depth |
87
|
| digital input modules |
8 Point 120V AC Input Module
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Digital
|
| Number Of Channels |
8 Point
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| Number of digital inputs |
8
|
|---|---|
| Time delay at signal exchange |
20 ms
|
| Suitable for safety functions |
False
|
| Digital inputs configurable |
False
|
| Digital outputs configurable |
False
|
| Type of voltage (input voltage) |
AC
|
| Type of electric connection |
Screw connection
|
| Nominal Impedance |
12 kΩ @ 50 Hz
|
| Number of commons |
1
|
| Heat dissipation, max |
2 W
|
| Bus current draw, max |
50mA @ 5V DC (0.25 W)
|
| ON-state current, max |
16.0mA @ 132V AC, 63 Hz
|
| Inrush current, max |
250 mA
|
| Power supply distance rating |
6 (the module may not be more than 6 modules away from the system power supply)
|
| On-state current, nom |
12.0mA @ 120V AC, 60 Hz
|
| Isolated groups |
Group 1: inputs 0...7 (internally connected commons)
|
| Input group to backplane isolation |
Verified by one of the following dielectric tests: 1517V AC @ 1s or 2145V DC @ 1s. 132V AC working voltage (IEC Class 2 reinforced insulation)
|
| Redundancy |
False
|
| Short-circuit protection, outputs available |
False
|
| Width |
40.4 mm
|
|---|---|
| Height |
90 mm
|
| Depth |
87 mm
|
| Weight |
209 g
|
| Shock |
Operating: 30G panel mounted, 3 pulses per axis, Relay ops: 7G
|
| Vibration |
Operating: 10...500 Hz, 5 G, 0.015 in. maximum, peak-to-peak, 2 hr each axis, Relay ops: 1.5 G
|
| IEC input compatibility |
Type 1+
|
|---|
| IEC input compatibility |
Type 1+
|
|---|
| Signal delay |
On delay: 20.0 ms
|
|---|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
|---|---|
| Conducted RF immunity |
IEC 1000-4-6: 10V @ 0.15...80MHz
|
| EFT/B immunity |
IEC1000-4-4: 2kV @ 5kHz
|
| Hazardous environment class |
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
| Operating temperature |
-20 to 65 °C
|
| Surge transient immunity |
IEC1000-4-5: 2 kV common mode, 1kV differential mode
|
| Radiated RF immunity |
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Altitude |
2000 m
|
| Storage temperature, min |
-40 °C
|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Operating humidity |
5...95% noncondensing
|
Drawings
| Drawings | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
Documents
|
Selection Guide
General
1761-SG001 |
|
Product Cutsheet
General
-- |
| General | Publication |
|---|---|
| Selection Guide | 1761-SG001 |
| Product Cutsheet | -- |
Certifications
- UL Listed Hazardous
This product was certified with the above certifications as of {}. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Technotes
| Technotes |
|---|