MicroLogix 8 Point Digital Input Module
MicroLogix 8 Point Digital Input Module
| Unique Product Identifier |
1762-IA8
|
|---|---|
| UPC |
612598207183
|
| Estimated Lead Time |
5 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Malaysia
|
| Class |
Progmable Logic Controller
|
|---|---|
| Depth |
87
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Digital
|
| Number Of Channels |
8 Point
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| digital input modules |
8 Point 120V AC Input Module
|
| Bus current draw, max |
50mA @ 5V DC (0.25 W)
|
|---|---|
| Digital inputs configurable |
False
|
| Digital outputs configurable |
False
|
| Heat dissipation, max |
2 W
|
| Input group to backplane isolation |
Verified by one of the following dielectric tests: 1517V AC @ 1s or 2145V DC @ 1s. 132V AC working voltage (IEC Class 2 reinforced insulation)
|
| Inrush current, max |
250 mA
|
| Isolated groups |
Group 1: inputs 0...7 (internally connected commons)
|
| Nominal Impedance |
12 kΩ @ 50 Hz
|
| Number of commons |
1
|
| Number of digital inputs |
8
|
| ON-state current, max |
16.0mA @ 132V AC, 63 Hz
|
| On-state current, nom |
12.0mA @ 120V AC, 60 Hz
|
| Power supply distance rating |
6 (the module may not be more than 6 modules away from the system power supply)
|
| Redundancy |
False
|
| Short-circuit protection, outputs available |
False
|
| Suitable for safety functions |
False
|
| Time delay at signal exchange |
20 ms
|
| Type of electric connection |
Screw connection
|
| Type of voltage (input voltage) |
AC
|
| Off-state current, max |
2.5 mA
|
|---|---|
| Off-state voltage, max |
20V AC
|
| On-state current, min |
5.0mA @ 79V AC, 47 Hz
|
| On-state voltage, min |
79V...132V AC
|
| Operating voltage |
79...132V AC @ 47...63Hz
|
| Voltage category |
100/120V AC
|
| Signal delay |
On delay: 20.0 ms
|
|---|
| Altitude |
2000 m
|
|---|---|
| Conducted RF immunity |
IEC 1000-4-6: 10V @ 0.15...80MHz
|
| EFT/B immunity |
IEC1000-4-4: 2kV @ 5kHz
|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
| Hazardous environment class |
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
| Operating humidity |
5...95% noncondensing
|
| Operating temperature |
-20 to 65 °C
|
| Radiated RF immunity |
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Storage temperature, min |
-40 °C
|
| Surge transient immunity |
IEC1000-4-5: 2 kV common mode, 1kV differential mode
|
| Depth |
87 mm
|
|---|---|
| Height |
90 mm
|
| Shock |
Operating: 30G panel mounted, 3 pulses per axis, Relay ops: 7G
|
| Vibration |
Operating: 10...500 Hz, 5 G, 0.015 in. maximum, peak-to-peak, 2 hr each axis, Relay ops: 1.5 G
|
| Weight |
209 g
|
| Width |
40.4 mm
|
| IEC input compatibility |
Type 1+
|
|---|
| Drawings | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
| General | Publication |
|---|---|
| Selection Guide | 1761-SG001 |
| Product Cutsheet | -- |
This product was certified with the above certifications as of 2026-08-11. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for certification documents?
Explore certifications for this product and more in our comprehensive Literature Library.
| EU Importer Address |
Rockwell Automation N.V |
|---|---|
| EU Authorized Representative Address |
Rockwell Automation N.V |
| Technotes |
|---|
Overview
| Unique Product Identifier |
1762-IA8
|
|---|---|
| UPC |
612598207183
|
| Estimated Lead Time |
5 days
|
| Standard Warranty Duration |
1 year See details |
| Country of Origin |
Malaysia
|
Electrical & Connectivity
| Class |
Progmable Logic Controller
|
|---|---|
| Depth |
87
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Digital
|
| Number Of Channels |
8 Point
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| digital input modules |
8 Point 120V AC Input Module
|
| Bus current draw, max |
50mA @ 5V DC (0.25 W)
|
|---|---|
| Digital inputs configurable |
False
|
| Digital outputs configurable |
False
|
| Heat dissipation, max |
2 W
|
| Input group to backplane isolation |
Verified by one of the following dielectric tests: 1517V AC @ 1s or 2145V DC @ 1s. 132V AC working voltage (IEC Class 2 reinforced insulation)
|
| Inrush current, max |
250 mA
|
| Isolated groups |
Group 1: inputs 0...7 (internally connected commons)
|
| Nominal Impedance |
12 kΩ @ 50 Hz
|
| Number of commons |
1
|
| Number of digital inputs |
8
|
| ON-state current, max |
16.0mA @ 132V AC, 63 Hz
|
| On-state current, nom |
12.0mA @ 120V AC, 60 Hz
|
| Power supply distance rating |
6 (the module may not be more than 6 modules away from the system power supply)
|
| Redundancy |
False
|
| Short-circuit protection, outputs available |
False
|
| Suitable for safety functions |
False
|
| Time delay at signal exchange |
20 ms
|
| Type of electric connection |
Screw connection
|
| Type of voltage (input voltage) |
AC
|
| Off-state current, max |
2.5 mA
|
|---|---|
| Off-state voltage, max |
20V AC
|
| On-state current, min |
5.0mA @ 79V AC, 47 Hz
|
| On-state voltage, min |
79V...132V AC
|
| Operating voltage |
79...132V AC @ 47...63Hz
|
| Voltage category |
100/120V AC
|
| Signal delay |
On delay: 20.0 ms
|
|---|
Compliance & Environment
| Altitude |
2000 m
|
|---|---|
| Conducted RF immunity |
IEC 1000-4-6: 10V @ 0.15...80MHz
|
| EFT/B immunity |
IEC1000-4-4: 2kV @ 5kHz
|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
| Hazardous environment class |
Class I, Division 2, Hazardous Location, Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
| Operating humidity |
5...95% noncondensing
|
| Operating temperature |
-20 to 65 °C
|
| Radiated RF immunity |
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Storage temperature, min |
-40 °C
|
| Surge transient immunity |
IEC1000-4-5: 2 kV common mode, 1kV differential mode
|
Physical Characteristics
| Depth |
87 mm
|
|---|---|
| Height |
90 mm
|
| Shock |
Operating: 30G panel mounted, 3 pulses per axis, Relay ops: 7G
|
| Vibration |
Operating: 10...500 Hz, 5 G, 0.015 in. maximum, peak-to-peak, 2 hr each axis, Relay ops: 1.5 G
|
| Weight |
209 g
|
| Width |
40.4 mm
|
Technical Specifications
| IEC input compatibility |
Type 1+
|
|---|
Drawings
| Drawings | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
Documents
|
Selection Guide
General
1761-SG001 |
|
Product Cutsheet
General
-- |
| General | Publication |
|---|---|
| Selection Guide | 1761-SG001 |
| Product Cutsheet | -- |
Certifications
This product was certified with the above certifications as of 2026-08-11. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Looking for certification documents?
Explore certifications for this product and more in our comprehensive Literature Library.
| EU Importer Address |
Rockwell Automation N.V |
|---|---|
| EU Authorized Representative Address |
Rockwell Automation N.V |
Technotes
| Technotes |
|---|