View all MicroLogix Expansion I/O Modules
1762-IQ8
MicroLogix 8 Point Digital Input Module
Product at a glance
Product at a glance
| Class |
Progmable Logic Controller Module
|
|---|---|
| Depth |
87
|
| digital input modules |
8 Point 24V DC Sink/Source Input Module
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Digital
|
| Number Of Channels |
8 Point
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| Number of digital inputs |
8
|
|---|---|
| Time delay at signal exchange |
8 ms
|
| Suitable for safety functions |
False
|
| Digital inputs configurable |
False
|
| Digital outputs configurable |
False
|
| Type of voltage (input voltage) |
DC
|
| Type of electric connection |
Screw connection
|
| Nominal Impedance |
3 kΩ
|
| Number of commons |
1
|
| Heat dissipation, max |
3.7 W
|
| Bus current draw, max |
50mA @ 5V DC (0.25 W)
|
| ON-state current, max |
12.0mA @ 30V DC
|
| Power supply distance rating |
6 (the module may not be more than 6 modules away from the system power supply)
|
| On-state current, nom |
8.0mA @ 24V DC
|
| Isolated groups |
Group 1: inputs 0...7 (internally connected commons)
|
| Input group to backplane isolation |
Verified by one of the following dielectric tests: 1200V AC @ 1s or 1697V DC @ 1s, 75V DC working voltage (IEC Class 2 reinforced insulation)
|
| Redundancy |
False
|
| Short-circuit protection, outputs available |
False
|
| Width |
40.4 mm
|
|---|---|
| Height |
90 mm
|
| Depth |
87 mm
|
| Weight |
200 g
|
| Shock |
Operating: 30G panel mounted, 3 pulses per axis, Relay ops: 7G
|
| Vibration |
Operating: 10 to 500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops : 1.5G
|
| IEC input compatibility |
Type 1+
|
|---|
| IEC input compatibility |
Type 1+
|
|---|
| Signal delay |
On delay: 8.0 ms
|
|---|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
|---|---|
| Conducted RF immunity |
IEC 1000-4-6: 10V @ 0.15...80MHz
|
| EFT/B immunity |
IEC1000-4-4: 2kV @ 5kHz
|
| Hazardous environment class |
Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
| Operating temperature |
-20 to 65 °C
|
| Surge transient immunity |
IEC1000-4-5: 2 kV common mode, 1 kV differential mode
|
| Radiated RF immunity |
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Altitude |
2000 m
|
| Storage temperature, min |
-40 °C
|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Operating humidity |
5...95% noncondensing
|
| Drawings | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
| General | Publication |
|---|---|
| Product Cutsheet | -- |
| Selection Guide | 1761-SG001 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
- UL Listed Hazardous
This product was certified with the above certifications as of {}. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
| Technotes |
|---|
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
| Class |
Progmable Logic Controller Module
|
|---|---|
| Depth |
87
|
| digital input modules |
8 Point 24V DC Sink/Source Input Module
|
| Height |
90
|
| I/O Isolation |
Isolated
|
| I/O Status Indication |
LED
|
| Module Interfaces |
Digital
|
| Number Of Channels |
8 Point
|
| Temperature Rating |
0…55 °C (32…131 °F)
|
| Number of digital inputs |
8
|
|---|---|
| Time delay at signal exchange |
8 ms
|
| Suitable for safety functions |
False
|
| Digital inputs configurable |
False
|
| Digital outputs configurable |
False
|
| Type of voltage (input voltage) |
DC
|
| Type of electric connection |
Screw connection
|
| Nominal Impedance |
3 kΩ
|
| Number of commons |
1
|
| Heat dissipation, max |
3.7 W
|
| Bus current draw, max |
50mA @ 5V DC (0.25 W)
|
| ON-state current, max |
12.0mA @ 30V DC
|
| Power supply distance rating |
6 (the module may not be more than 6 modules away from the system power supply)
|
| On-state current, nom |
8.0mA @ 24V DC
|
| Isolated groups |
Group 1: inputs 0...7 (internally connected commons)
|
| Input group to backplane isolation |
Verified by one of the following dielectric tests: 1200V AC @ 1s or 1697V DC @ 1s, 75V DC working voltage (IEC Class 2 reinforced insulation)
|
| Redundancy |
False
|
| Short-circuit protection, outputs available |
False
|
| Width |
40.4 mm
|
|---|---|
| Height |
90 mm
|
| Depth |
87 mm
|
| Weight |
200 g
|
| Shock |
Operating: 30G panel mounted, 3 pulses per axis, Relay ops: 7G
|
| Vibration |
Operating: 10 to 500 Hz, 5G, 0.030 in. max. peak-to-peak, 2 hr per axis Relay ops : 1.5G
|
| IEC input compatibility |
Type 1+
|
|---|
| IEC input compatibility |
Type 1+
|
|---|
| Signal delay |
On delay: 8.0 ms
|
|---|
| ESD immunity |
IEC1000-4-2: 4kV contact, 8kV air, 4kV indirect
|
|---|---|
| Conducted RF immunity |
IEC 1000-4-6: 10V @ 0.15...80MHz
|
| EFT/B immunity |
IEC1000-4-4: 2kV @ 5kHz
|
| Hazardous environment class |
Hazardous Location, Class I, Division 2 Groups A, B, C, D (UL 1604, C-UL under CSA C22.2 No. 213)
|
| Operating temperature |
-20 to 65 °C
|
| Surge transient immunity |
IEC1000-4-5: 2 kV common mode, 1 kV differential mode
|
| Radiated RF immunity |
IEC1000-4-3: 10 V/m, 80...1,000 MHz, 80% Alitude modulation, +900 MHz keyed carrier
|
| Altitude |
2000 m
|
| Storage temperature, min |
-40 °C
|
| Radiated and conducted emissions |
EN50081-2: Class A
|
| Operating humidity |
5...95% noncondensing
|
Drawings
| Drawings | |
|---|---|
| 3-Dimensional STEP model (STP) | Download (ZIP) |
| Product Drawing | Drawing (DWG) |
| Drawings |
|---|
| 3-Dimensional STEP model (STP) Download (ZIP) |
| Product Drawing Drawing (DWG) |
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Documents
|
Product Cutsheet
General
-- |
|
Selection Guide
General
1761-SG001 |
| General | Publication |
|---|---|
| Product Cutsheet | -- |
| Selection Guide | 1761-SG001 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Certifications
- UL Listed Hazardous
This product was certified with the above certifications as of {}. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.
Technotes
| Technotes |
|---|
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase