1756-OF8H

ControlLogix 8 Pt A/O I or V HART Module

PrintPrint
Print
EmailEmail
Share
Product RegistrationProduct Registration
Scan code
Allen-Bradley 1756-OF8H product image
Allen-Bradley 1756-OF8H product image
Allen-Bradley 1756-OF8H product image
Allen Bradley
Lifecycle status: Active
Product at a glance
Repair Options Available
Lifecycle status: Active
Product at a glance
Repair Options Available
Add to BoM
  • Add to Repair Quote
  • Get Support
Repair Options
CloseClose
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
Schedule a repair Request repair documentation Repair terms and conditions
Technical Specifications
Drawings
Documents
Downloads
Certifications
Technotes
Isolation None between channels (Single Ended)
Number Of Channels 8
Output Signal +/- 10.4V, 0-20 mA, 4-20 mA
Input, current True
Input, voltage True
Input, resistor False
Input, resistance thermometer False
Input, thermocouple False
Input signal, configurable True
Output, current False
Output, voltage False
Output signal configurable False
Analogue inputs configurable True
Analogue outputs configurable False
Type of electric connection Screw-/spring clA connection
Wire type Copper
Output range -10…10V, 0…20 mA, 4…20 mA
Load reactance Voltage: 1 µF, Current: 10 µH
Terminal block torque specifications 1756-TBNH: 1.36 Nm (12 in-lb.)
Input conversion method Successive approximation
Module keying Electronic, software configurable
Offset drift 100 µV/°C, 200 nA/°C
Output conversion method R-Ladder DAC, monotonicity with no missing codes
Outputs Eight voltage or current, one HART modem per module
Data format Integer mode (left justified, 2 s complement) IEEE 32-bit floating point
Wire category 2 - on signal ports
Overvoltage protection ±24V DC
Module error Voltage: 0.15% of range, Current: 0.3% of range
Gain drift with temperature Voltage: 20 ppm/°C, Current: 35 ppm/°C
Voltage and current ratings Backplane: 5.1V DC @ 230mA, 24V DC @ 230mA, Output voltage: -10...+10.4V, Output current: 4...20 mA
Settling time Current (no HART): <23 ms to 95% with resistive loads, current (with HART): <37 ms to 95% with resistive loads, voltage: <8.5 ms to 95% with resistive loads
Total backplane power 6.54 W
Thermal dissipation 16.78 BTU/h
Power dissipation 4.92 W
Resolution 15...16 bit for all ranges
Wire size 1756-TBNH: Single wire connection: 0.33...2.1 mm² (22...14 AWG) solid or stranded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation maximum, 1756-TBNH: Double wire connection: 0.33...1.3 mm² (22...16 AWG) solid or stranded cop
Calibrated accuracy Voltage: Better than 0.1% of range @ 25 °C (77 °F) with HART disabled, Current: Better than 0.15% of range @ 25 °C (77 °F) with HART disabled
Open circuit detection time Current output only (output must be set to <0.1 mA)
Module HART scan time Analog: 12 ms, minimum, floating point, HART: typically 1 s per HART channel enabled. Estimate 10 s if all 8 channels have HART enabled, Pass through messages, handheld communicators, sary masters, communication errors, or configuration changes can s
Suitable for safety functions False
Surrounding air temperature, max 60 °C
North American temperature code T4
Emissions IEC 61000-6-4
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±2kV @ 5kHz on signal ports
Relative humidity 5...95% noncondensing
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity ±2kV line-earth (CM) on shielded ports
Operating temperature 0 °C <Ta <60 °C (32 °F <Ta <140 °F)
Radiated RF immunity 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Nonoperating temperature -40 °C
RTB keying User-defined mechanical
Vibration 2 G @ 10...500 Hz
Shock Operating: 30 G, Non operating: 50 G
Slot width 1
Calibration interval 12 mo typical
ATEX temperature code T4
IECEx temperature code T4
Isolation voltage 50V (continuous), basic insulation type, output channels to backplane, No isolation between individual output channels type tested at 1500V AC @ 60s
Enclosure type rating None (open-style)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Type Resource Publication
General User Manual 1756-UM533
General Product Cutsheet --
General Technical Detail --
General Product Profile --
General Selection Guide 1756-SG001
Technical Data 1756-td002_-en-e 1756-TD002
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
Available Downloads
  • Firmware for 1756-OF8H v2.002
  • AOP - Add On Profiles for 1756 HART I/O v40.12.23
See All Downloads Chevron RightChevron Right
  • Safety
  • American Bureau of Shippin

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Isolation None between channels (Single Ended)
Number Of Channels 8
Output Signal +/- 10.4V, 0-20 mA, 4-20 mA
Input, current True
Input, voltage True
Input, resistor False
Input, resistance thermometer False
Input, thermocouple False
Input signal, configurable True
Output, current False
Output, voltage False
Output signal configurable False
Analogue inputs configurable True
Analogue outputs configurable False
Type of electric connection Screw-/spring clA connection
Wire type Copper
Output range -10…10V, 0…20 mA, 4…20 mA
Load reactance Voltage: 1 µF, Current: 10 µH
Terminal block torque specifications 1756-TBNH: 1.36 Nm (12 in-lb.)
Input conversion method Successive approximation
Module keying Electronic, software configurable
Offset drift 100 µV/°C, 200 nA/°C
Output conversion method R-Ladder DAC, monotonicity with no missing codes
Outputs Eight voltage or current, one HART modem per module
Data format Integer mode (left justified, 2 s complement) IEEE 32-bit floating point
Wire category 2 - on signal ports
Overvoltage protection ±24V DC
Module error Voltage: 0.15% of range, Current: 0.3% of range
Gain drift with temperature Voltage: 20 ppm/°C, Current: 35 ppm/°C
Voltage and current ratings Backplane: 5.1V DC @ 230mA, 24V DC @ 230mA, Output voltage: -10...+10.4V, Output current: 4...20 mA
Settling time Current (no HART): <23 ms to 95% with resistive loads, current (with HART): <37 ms to 95% with resistive loads, voltage: <8.5 ms to 95% with resistive loads
Total backplane power 6.54 W
Thermal dissipation 16.78 BTU/h
Power dissipation 4.92 W
Resolution 15...16 bit for all ranges
Wire size 1756-TBNH: Single wire connection: 0.33...2.1 mm² (22...14 AWG) solid or stranded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation maximum, 1756-TBNH: Double wire connection: 0.33...1.3 mm² (22...16 AWG) solid or stranded cop
Calibrated accuracy Voltage: Better than 0.1% of range @ 25 °C (77 °F) with HART disabled, Current: Better than 0.15% of range @ 25 °C (77 °F) with HART disabled
Open circuit detection time Current output only (output must be set to <0.1 mA)
Module HART scan time Analog: 12 ms, minimum, floating point, HART: typically 1 s per HART channel enabled. Estimate 10 s if all 8 channels have HART enabled, Pass through messages, handheld communicators, sary masters, communication errors, or configuration changes can s
Suitable for safety functions False
Surrounding air temperature, max 60 °C
North American temperature code T4
Emissions IEC 61000-6-4
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±2kV @ 5kHz on signal ports
Relative humidity 5...95% noncondensing
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity ±2kV line-earth (CM) on shielded ports
Operating temperature 0 °C <Ta <60 °C (32 °F <Ta <140 °F)
Radiated RF immunity 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Nonoperating temperature -40 °C
RTB keying User-defined mechanical
Vibration 2 G @ 10...500 Hz
Shock Operating: 30 G, Non operating: 50 G
Slot width 1
Calibration interval 12 mo typical
ATEX temperature code T4
IECEx temperature code T4
Isolation voltage 50V (continuous), basic insulation type, output channels to backplane, No isolation between individual output channels type tested at 1500V AC @ 60s
Enclosure type rating None (open-style)
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Documents
User Manual General
1756-UM533
Product Cutsheet General
--
Technical Detail General
--
Product Profile General
--
Selection Guide General
1756-SG001
1756-td002_-en-e Technical Data
1756-TD002
Type Resource Publication
General User Manual 1756-UM533
General Product Cutsheet --
General Technical Detail --
General Product Profile --
General Selection Guide 1756-SG001
Technical Data 1756-td002_-en-e 1756-TD002
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
Downloads
Available Downloads
  • Firmware for 1756-OF8H v2.002
  • AOP - Add On Profiles for 1756 HART I/O v40.12.23
See All Downloads Chevron RightChevron Right
Certifications
  • Safety
  • American Bureau of Shippin

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
ControlLogix 8 Pt A/O I or V HART Module
CloseClose
1756-OF8H
Close
Print
Chevron LeftChevron Left
Allen-Bradley 1756-OF8H product image
Chevron RightChevron Right
Chevron LeftChevron Left
Allen-Bradley 1756-OF8H product image
Allen-Bradley 1756-OF8H product image
Chevron RightChevron Right
Phone:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation Home Chevron RightChevron Right
  2. Chevron LeftChevron Left Products Chevron RightChevron Right
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose