Loading
  • alt text
alt text
Best Selling
1756-IF4FXOF2F

ControlLogix 4 Point Analog Comb Module

PrintPrint
Print
EmailEmail
Share
Product RegistrationProduct Registration
QR code
Allen-Bradley 1756-IF4FXOF2F product image
Lifecycle status: Active
Product at a glance
Build America, Buy America Build America, Buy America
Repair Options Available
Product Registration
Lifecycle status: Active
Product at a glance
Build America, Buy America Build America, Buy America
Repair Options Available
Product Registration
Add to BoM
  • Register Product
  • Get Support
Technical Specifications
General
Electrical
Environmental
Mechanical
Certification
General Specifications
Input Specifications
Power
Construction
Drawings
Documents
Downloads
Certifications
Alternative Products
Technotes
Output Signal
+/- 10.4V, 0-21mA
Input, current
True
Input, voltage
True
Input, resistor
False
Input, resistance thermometer
False
Input, thermocouple
False
Input signal, configurable
True
Output, current
False
Output, voltage
False
Output signal configurable
False
Analogue inputs configurable
True
Analogue outputs configurable
False
Type of electric connection
Screw-/spring clA connection
Output range
±10V, 0…20 mA
Terminal block torque specifications
1756-TBCH: 0.5 Nm (4.4 in-lb)
Input conversion method
Successive approximation
Module keying
Electronic, software configurable
Offset drift
50 µV/°C, 1 µV/°C
Output conversion method
R-Ladder DAC, monotonicity with no missing codes
Drive capability
Voltage: >2000 Ω, Current: 0...750 Ω
Input range
±10V @ 0...10V, 0...5V @ 0...20mA
Data format
Integer mode (left justified, 2 s complement) IEEE 32-bit floating point
Wire category
2 - on signal ports
Overvoltage protection
Voltage: 30V DC, input, Current: 8V AC/DC, input, Output: 24V DC
Module error
Input: 0.2% of range, Voltage: 0.2% of range, output, Current: 0.3% of range, output
Gain drift with temperature
Voltage: 25 ppm/°C maximum, input, Current: 35 ppm/°C maximum, input, Voltage: 25 ppm/°C maximum, output, Current: 50 ppm/°C maximum, output
Voltage and current ratings
Backplane: 375mA @ 5.1V DC, 100mA @ 24V DC, Analog inputs: -10...+10V @ 4...20mA, Analog outputs: -10...+10V @ 4...20mA
Module scan time
300 µs minimum
Thermal dissipation
Voltage: 14.66 BTU/hr, Current: 16.02 BTU/hr
Current draw
375mA @ 5.1V, 100mA @ 24V
Power dissipation
Voltage: 4.3 W, Current: 4.7 W
Resolution
Input: Approx 14 bit across ±10.5V DC (21V total), ±10.5V range: 1.3 mV/bit, 14 bit effective, 0...10.5V range: 1.3 mV/bit, 13 bit effective, 0...5.25V range: 1.3 mV/bit, 12 bit effective, Approx 12 bit across 21mA @ 0...21mA range: 5.25 µA/bit, Output
Wire size
Single wire connection (1756-TBCH): 0.33...2.1 mm² (22...14 AWG) solid or stranded shielded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation maximum, Single wire connection (1756-TBS6H): 0.33...2.1 mm² (22...14 AWG) solid or
Calibrated accuracy
Input: 0.05% of range immediately after calibration Better than 0.1% of range within calibration interval @ 25 °C (77 °F), Output: 0.05% of range immediately after calibration Better than 0.1% of range within calibration interval @ 25 °C (77 °F)
Open circuit detection time
Input: Positive full-scale reading within 1 s, Output: Current output only (output must be set to >0.1 mA)
Suitable for safety functions
False
Update period for all channels (RPI), min
1 ms
Number, output
2 high-speed voltage or current
Number, input
4 high-speed, subms, differential
Short circuit protection
Electronically current limited to 21 mA or less
Output settling time
<2 ms to 95% of final value with resistive loads
Surrounding air temperature, max
60 °C
North American temperature code
T4A
Power consumption
4.3 W
Emissions
IEC 61000-6-4
ESD immunity
6 kV contact discharges, 8 kV air discharges
EFT/B immunity
±2kV @ 5kHz on shielded signal ports
Relative humidity
5...95% noncondensing
Conducted RF immunity
10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
Surge transient immunity
±2 kV line-earth (CM) on shielded signal ports
Operating temperature
0 °C <60 °C (32 °F <140 °F)
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2700...6
Nonoperating temperature
-40 °C
RTB keying
User-defined mechanical
Vibration
2 G @ 10...500 Hz
Shock
Operating: 30 G, Non operating: 50 G
Slot width
1
Calibration interval
Input: 12 mo, Output: 12 mo
ATEX temperature code
T4
IECEx temperature code
T4
Repeatability
±1 least significant bit (LSB)
Input impedance
Voltage: >1 MΩ, Current: 249 Ω
Isolation voltage
250V (continuous), Reinforced insulation type, inputs and outputs to backplane, No isolation between individual inputs or outputs
Enclosure type rating
None (open-style)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DWG)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Type Resource Publication
General Technical Detail --
General Product Cutsheet --
General Product Profile --
General Selection Guide 1756-SG001
Technical Data 1756-td002_-en-e 1756-TD002
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Search the Literature Library
Available Downloads
  • Firmware for 1756-IF4FXOF2F Analog I/O
  • EDS files for 1756-IF4FXOF2F (multi)
  • EDS files for ControlLogix Family (multi)
  • AOP - Add On Profiles for 1756 Analog I/O v40.12.23
  • AOP - Add On Profiles for 1756-IF8, IF16, OF4, OF8 v40.13.06
  • AOP - Add On Profiles for 1756 Analog1 v40.14.70
See All Downloads
China CCC ATEX IECEx Scheme Australian RCM Eurasion Economic Community
  • China CCC
  • CE
  • ATEX
  • IECEx Scheme
  • Australian RCM
  • MOROCCO DOC
  • Eurasion Economic Community

This product was certified with the above certifications as of 2025-11-24. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Items Per Page:
1-1 of 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
Output Signal
+/- 10.4V, 0-21mA
Input, current
True
Input, voltage
True
Input, resistor
False
Input, resistance thermometer
False
Input, thermocouple
False
Input signal, configurable
True
Output, current
False
Output, voltage
False
Output signal configurable
False
Analogue inputs configurable
True
Analogue outputs configurable
False
Type of electric connection
Screw-/spring clA connection
Output range
±10V, 0…20 mA
Terminal block torque specifications
1756-TBCH: 0.5 Nm (4.4 in-lb)
Input conversion method
Successive approximation
Module keying
Electronic, software configurable
Offset drift
50 µV/°C, 1 µV/°C
Output conversion method
R-Ladder DAC, monotonicity with no missing codes
Drive capability
Voltage: >2000 Ω, Current: 0...750 Ω
Input range
±10V @ 0...10V, 0...5V @ 0...20mA
Data format
Integer mode (left justified, 2 s complement) IEEE 32-bit floating point
Wire category
2 - on signal ports
Overvoltage protection
Voltage: 30V DC, input, Current: 8V AC/DC, input, Output: 24V DC
Module error
Input: 0.2% of range, Voltage: 0.2% of range, output, Current: 0.3% of range, output
Gain drift with temperature
Voltage: 25 ppm/°C maximum, input, Current: 35 ppm/°C maximum, input, Voltage: 25 ppm/°C maximum, output, Current: 50 ppm/°C maximum, output
Voltage and current ratings
Backplane: 375mA @ 5.1V DC, 100mA @ 24V DC, Analog inputs: -10...+10V @ 4...20mA, Analog outputs: -10...+10V @ 4...20mA
Module scan time
300 µs minimum
Thermal dissipation
Voltage: 14.66 BTU/hr, Current: 16.02 BTU/hr
Current draw
375mA @ 5.1V, 100mA @ 24V
Power dissipation
Voltage: 4.3 W, Current: 4.7 W
Resolution
Input: Approx 14 bit across ±10.5V DC (21V total), ±10.5V range: 1.3 mV/bit, 14 bit effective, 0...10.5V range: 1.3 mV/bit, 13 bit effective, 0...5.25V range: 1.3 mV/bit, 12 bit effective, Approx 12 bit across 21mA @ 0...21mA range: 5.25 µA/bit, Output
Wire size
Single wire connection (1756-TBCH): 0.33...2.1 mm² (22...14 AWG) solid or stranded shielded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation maximum, Single wire connection (1756-TBS6H): 0.33...2.1 mm² (22...14 AWG) solid or
Calibrated accuracy
Input: 0.05% of range immediately after calibration Better than 0.1% of range within calibration interval @ 25 °C (77 °F), Output: 0.05% of range immediately after calibration Better than 0.1% of range within calibration interval @ 25 °C (77 °F)
Open circuit detection time
Input: Positive full-scale reading within 1 s, Output: Current output only (output must be set to >0.1 mA)
Suitable for safety functions
False
Update period for all channels (RPI), min
1 ms
Number, output
2 high-speed voltage or current
Number, input
4 high-speed, subms, differential
Short circuit protection
Electronically current limited to 21 mA or less
Output settling time
<2 ms to 95% of final value with resistive loads
Surrounding air temperature, max
60 °C
North American temperature code
T4A
Power consumption
4.3 W
Emissions
IEC 61000-6-4
ESD immunity
6 kV contact discharges, 8 kV air discharges
EFT/B immunity
±2kV @ 5kHz on shielded signal ports
Relative humidity
5...95% noncondensing
Conducted RF immunity
10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
Surge transient immunity
±2 kV line-earth (CM) on shielded signal ports
Operating temperature
0 °C <60 °C (32 °F <140 °F)
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2700...6
Nonoperating temperature
-40 °C
RTB keying
User-defined mechanical
Vibration
2 G @ 10...500 Hz
Shock
Operating: 30 G, Non operating: 50 G
Slot width
1
Calibration interval
Input: 12 mo, Output: 12 mo
ATEX temperature code
T4
IECEx temperature code
T4
Repeatability
±1 least significant bit (LSB)
Input impedance
Voltage: >1 MΩ, Current: 249 Ω
Isolation voltage
250V (continuous), Reinforced insulation type, inputs and outputs to backplane, No isolation between individual inputs or outputs
Enclosure type rating
None (open-style)
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DWG)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Documents
Technical Detail General
--
Product Cutsheet General
--
Product Profile General
--
Selection Guide General
1756-SG001
1756-td002_-en-e Technical Data
1756-TD002
Type Resource Publication
General Technical Detail --
General Product Cutsheet --
General Product Profile --
General Selection Guide 1756-SG001
Technical Data 1756-td002_-en-e 1756-TD002
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Search the Literature Library
Downloads
Available Downloads
  • Firmware for 1756-IF4FXOF2F Analog I/O
  • EDS files for 1756-IF4FXOF2F (multi)
  • EDS files for ControlLogix Family (multi)
  • AOP - Add On Profiles for 1756 Analog I/O v40.12.23
  • AOP - Add On Profiles for 1756-IF8, IF16, OF4, OF8 v40.13.06
  • AOP - Add On Profiles for 1756 Analog1 v40.14.70
See All Downloads
Certifications
China CCC ATEX IECEx Scheme Australian RCM Eurasion Economic Community
  • China CCC
  • CE
  • ATEX
  • IECEx Scheme
  • Australian RCM
  • MOROCCO DOC
  • Eurasion Economic Community

This product was certified with the above certifications as of 2025-11-24. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Alternative Products
Items Per Page:
1-1 of 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading
Find your nearest distributor
Contact your distributor in {0}
Change location
EmailEmail
PhonePhone
Find a partner
ControlLogix 4 Point Analog Comb Module
CloseClose
1756-IF4FXOF2F
Close
Print
Allen-Bradley 1756-IF4FXOF2F product image
Phone:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
Sign in to your Rockwell Automation account to submit a repair documentation request.
Sign In
Request repair documentation
All fields with * are required for processing your request.
This field is required
This field is required
This field is required
This field is required
This field is required
Documentation of liability insurance is required for anyone who is requesting documentation for product repairs.
UploadUpload
Please upload documentation of liability insurance.*
1 file selected
CloseClose
File size is too large. Must be less than 5 MB.
Accepted file types: zip, pdf; Maximum size: 5 MB.
Right to Repair Terms and Conditions
Rockwell Automation is making, parts, and service documentation available at your request in compliance with applicable right to repair laws and regulations. By signing below, you are agreeing to the following terms and conditions of your purchase of Rockwell Automation genuine repair parts for repair of a Rockwell Automation product. As used below, “Self Service Repair Parts” means genuine Rockwell Automation parts (components of Rockwell Automation products) purchased from Rockwell Automation for installation in a Rockwell Automation product as part of a Self Service Repair. Self Service Repair Parts may be new or previously used genuine Rockwell Automation parts that have been tested and passed Rockwell Automation functional requirements. “Self Service Repair Tools” means equipment and related materials purchased for the purpose of performing repairs.
Your request has been successfully submitted.
Please allow up to 5 business days to receive a response to your inquiry.
  1. Chevron LeftChevron Left Rockwell Automation Home
  2. Chevron LeftChevron Left Products
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose