Loading
Chevron UpChevron Up
Allen-Bradley 1756-en2t product image
Allen-Bradley 1756-en2t product image
Chevron DownChevron Down
Allen-Bradley 1756-en2t product image
Allen Bradley
Best Selling
1756-en2t

CLX ENet/IP 100M

PrintPrint
Print
EmailEmail
Share
Product RegistrationProduct Registration
Scan code
Allen-Bradley 1756-en2t product image
Allen-Bradley 1756-en2t product image
Allen-Bradley 1756-en2t product image
Allen Bradley
Lifecycle status: Active
Product at a glance
Build America, Buy America Build America, Buy America
Repair Options Available
Product Registration
Lifecycle status: Active
Product at a glance
Build America, Buy America Build America, Buy America
Repair Options Available
Product Registration
Add to BoM
  • Register Product
  • Add to Repair Quote
  • Get Support
Repair Options
CloseClose
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
Schedule a repair Request repair documentation Repair terms and conditions
Technical Specifications
Drawings
Documents
Certifications
Technotes
Communication Ethernet/IP
Interface 1 Copper RJ45 (10/100 Mbps)
Number Of Channels 1
With optical interface False
Supporting protocol for TCP/IP True
Supporting protocol for DeviceNet False
Supporting protocol for other bus systems False
Redundancy False
IO link master False
Supporting protocol for DeviceNet Safety False
Supporting protocol for EtherNet/IP True
Power dissipation 5.1 W
Thermal dissipation 17.4 btu/h
Enclosure type rating None (open-style)
Ethernet ports 1 Ethernet RJ45 Category 5
CIP unconnected messages 128 + 128 (backplane + Ethernet)
Current draw 1A @ 5.1V DC, 3mA @ 24V DC
Ethernet cable 802.3 compliant shielded or unshielded twisted pair
Wiring category 2 - on Ethernet ports, 3 - on USB ports
Communication rate 10/100 Mbps
Connections supported, max TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for exAle, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage 30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC @ 60s
Supporting protocol for LON False
Supporting protocol for ASI False
Supporting protocol for PROFIBUS False
Supporting protocol for CAN False
Supporting protocol for INTERBUS False
Supporting protocol for KNX False
Supporting protocol for Modbus False
Supporting protocol for Data-Highway False
Supporting protocol for SUCONET False
With potential separation False
Supporting protocol for SERCOS False
Supporting protocol for INTERBUS-Safety False
Radio standard Bluetooth False
Radio standard Wi-Fi 802.11 False
Supporting protocol for AS-Interface Safety at Work False
Supporting protocol for Foundation Fieldbus False
Supporting protocol for PROFINET CBA False
Supporting protocol for PROFINET IO False
Supporting protocol for PROFIsafe False
Supporting protocol for SafetyBUS p False
Radio standard GPRS False
Radio standard GSM False
Radio standard UMTS False
Slot width 1
ATEX temp code T4
Surrounding air temperature, max 60 °C
Storage temperature -40 °C <Ta <85 °C (-40 °F <Ta <185 °F)
Emissions CISPR 11: Class A
Vibration 2 G @ 10...500 Hz
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±3kV @ 5kHz on Ethernet ports
Relative humidity 5...95% noncondensing
Shock Operating: 30 G, Nonoperating: 30 G
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity ±2 kV line-earth (CM) on Ethernet ports
Operating temperature 0 °C <Ta <60 °C (32 °F <Ta <140 °F)
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3V/m with 1 kHz sine-wave 80% AM from 2000...6000 MHz
North American temperature code T4A
IECEx temperature code T4
Module location Chassis based, any slot
Drawings
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Type Resource Publication
General Product Cutsheet --
General Installation Instructions 1756-IN050
General Product Profile --
General Selection Guide 1756-SG001
Technical Data 1756-td003_-en-e 1756-TD003
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
China CCC ATEX Australian RCM IECEx Scheme Korean KC UL Listed
  • China CCC
  • Safety
  • American Bureau of Shippin
  • ATEX
  • CE
  • Australian RCM
  • IECEx Scheme
  • CSA Listed
  • CSA Listed Hazardous
  • FM Approved Haz
  • Korean KC
  • Registro Italiano Navale
  • ODVA
  • UL Listed
  • UL Listed Hazardous

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Communication Ethernet/IP
Interface 1 Copper RJ45 (10/100 Mbps)
Number Of Channels 1
With optical interface False
Supporting protocol for TCP/IP True
Supporting protocol for DeviceNet False
Supporting protocol for other bus systems False
Redundancy False
IO link master False
Supporting protocol for DeviceNet Safety False
Supporting protocol for EtherNet/IP True
Power dissipation 5.1 W
Thermal dissipation 17.4 btu/h
Enclosure type rating None (open-style)
Ethernet ports 1 Ethernet RJ45 Category 5
CIP unconnected messages 128 + 128 (backplane + Ethernet)
Current draw 1A @ 5.1V DC, 3mA @ 24V DC
Ethernet cable 802.3 compliant shielded or unshielded twisted pair
Wiring category 2 - on Ethernet ports, 3 - on USB ports
Communication rate 10/100 Mbps
Connections supported, max TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for exAle, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage 30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC @ 60s
Supporting protocol for LON False
Supporting protocol for ASI False
Supporting protocol for PROFIBUS False
Supporting protocol for CAN False
Supporting protocol for INTERBUS False
Supporting protocol for KNX False
Supporting protocol for Modbus False
Supporting protocol for Data-Highway False
Supporting protocol for SUCONET False
With potential separation False
Supporting protocol for SERCOS False
Supporting protocol for INTERBUS-Safety False
Radio standard Bluetooth False
Radio standard Wi-Fi 802.11 False
Supporting protocol for AS-Interface Safety at Work False
Supporting protocol for Foundation Fieldbus False
Supporting protocol for PROFINET CBA False
Supporting protocol for PROFINET IO False
Supporting protocol for PROFIsafe False
Supporting protocol for SafetyBUS p False
Radio standard GPRS False
Radio standard GSM False
Radio standard UMTS False
Slot width 1
ATEX temp code T4
Surrounding air temperature, max 60 °C
Storage temperature -40 °C <Ta <85 °C (-40 °F <Ta <185 °F)
Emissions CISPR 11: Class A
Vibration 2 G @ 10...500 Hz
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±3kV @ 5kHz on Ethernet ports
Relative humidity 5...95% noncondensing
Shock Operating: 30 G, Nonoperating: 30 G
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity ±2 kV line-earth (CM) on Ethernet ports
Operating temperature 0 °C <Ta <60 °C (32 °F <Ta <140 °F)
Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3V/m with 1 kHz sine-wave 80% AM from 2000...6000 MHz
North American temperature code T4A
IECEx temperature code T4
Module location Chassis based, any slot
Drawings
Drawings
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
Dimensional Drawing in 3D (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DXF)
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Documents
Product Cutsheet General
--
Installation Instructions General
1756-IN050
Product Profile General
--
Selection Guide General
1756-SG001
1756-td003_-en-e Technical Data
1756-TD003
Type Resource Publication
General Product Cutsheet --
General Installation Instructions 1756-IN050
General Product Profile --
General Selection Guide 1756-SG001
Technical Data 1756-td003_-en-e 1756-TD003
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library Chevron RightChevron Right
Certifications
China CCC ATEX Australian RCM IECEx Scheme Korean KC UL Listed
  • China CCC
  • Safety
  • American Bureau of Shippin
  • ATEX
  • CE
  • Australian RCM
  • IECEx Scheme
  • CSA Listed
  • CSA Listed Hazardous
  • FM Approved Haz
  • Korean KC
  • Registro Italiano Navale
  • ODVA
  • UL Listed
  • UL Listed Hazardous

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
CLX ENet/IP 100M
CloseClose
1756-en2t
Close
Print
Chevron LeftChevron Left
Allen-Bradley 1756-en2t product image
Chevron RightChevron Right
Chevron LeftChevron Left
Allen-Bradley 1756-en2t product image
Allen-Bradley 1756-en2t product image
Chevron RightChevron Right
Phone:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation Home Chevron RightChevron Right
  2. Chevron LeftChevron Left Products Chevron RightChevron Right
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose