Nominal value output voltage 1
24 V
Secondary voltage adjustable
True
Max. output current 1
5 A
Nominal value output current 1
5 A
Power output
120 W
Voltage type of supply voltage
AC/DC
1st secondary output voltage
24 V
Rated supply voltage at AC 50 Hz
100 V
Rated supply voltage at AC 60 Hz
100 V
Rated supply voltage at DC
110 V
Power reserves
20 %
Derating
3 w/°c
DC OK relay contact
True
Input inrush current limiter
Active
Adjustment range
24 V
Power factor
0.91 typical
Operational range
90…132V AC
Rated output current
5A @ 24V
External input fuse, min
B-6 A or C-6 A
Power losses
7.3 W typical
Sub group
Essential line
Hold-up time
>80 ms @ 120V
Efficiency
94.3% typical
Input inrush current
4 A/3 A
Special family function
Dynamic 120% power boost under 45C Degree
Rated input current
2.6A @ 100V AC
Output voltage stabilized
True
Rail mounting possible
True
Stabilized
True
Height
124 mm
Depth
102 mm
Direct mounting possible
False
Width
32 mm
Degree of protection (IP)
IP20
Type of electric connection
Screw connection
Shock
30 G, 6ms 20 G, 11ms
MTBF
867 kh (40 °C, SN29500)
Wall mounting possible
True
Vibration
2 g
Ripple and noise, max
50 mV
Operating temperature
-25 °C
Storage temperature
-25 °C
Lifetime, min
166 kh (+40 °C)
Relative humidity
5 to 95 %
Weight
440 g
Drawings
3D STEP model (STP) Download (ZIP)
Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Drawings
3D STEP model (STP) Download (ZIP)
Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Type Resource Publication
General Installation Instructions 1606-IN001
General Product Cutsheet --
Technical Data 1606-td002_-en-p 1606-TD002
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Australian RCM UL Listed ATEX IECEx Scheme Korean KC China CCC Eurasion Economic Community
  • Australian RCM
  • UL Listed
  • ATEX
  • IECEx Scheme
  • Korean KC
  • China CCC
  • DNV-GL
  • CE
  • Eurasion Economic Community

This product was certified with the above certifications as of 2025-09-09. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Items Per Page:
1-1 of 1
Items Per Page:
1-1 of 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
Nominal value output voltage 1
24 V
Secondary voltage adjustable
True
Max. output current 1
5 A
Nominal value output current 1
5 A
Power output
120 W
Voltage type of supply voltage
AC/DC
1st secondary output voltage
24 V
Rated supply voltage at AC 50 Hz
100 V
Rated supply voltage at AC 60 Hz
100 V
Rated supply voltage at DC
110 V
Power reserves
20 %
Derating
3 w/°c
DC OK relay contact
True
Input inrush current limiter
Active
Adjustment range
24 V
Power factor
0.91 typical
Operational range
90…132V AC
Rated output current
5A @ 24V
External input fuse, min
B-6 A or C-6 A
Power losses
7.3 W typical
Sub group
Essential line
Hold-up time
>80 ms @ 120V
Efficiency
94.3% typical
Input inrush current
4 A/3 A
Special family function
Dynamic 120% power boost under 45C Degree
Rated input current
2.6A @ 100V AC
Output voltage stabilized
True
Rail mounting possible
True
Stabilized
True
Height
124 mm
Depth
102 mm
Direct mounting possible
False
Width
32 mm
Degree of protection (IP)
IP20
Type of electric connection
Screw connection
Shock
30 G, 6ms 20 G, 11ms
MTBF
867 kh (40 °C, SN29500)
Wall mounting possible
True
Vibration
2 g
Ripple and noise, max
50 mV
Operating temperature
-25 °C
Storage temperature
-25 °C
Lifetime, min
166 kh (+40 °C)
Relative humidity
5 to 95 %
Weight
440 g
Drawings
Drawings
3D STEP model (STP) Download (ZIP)
Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Drawings
3D STEP model (STP) Download (ZIP)
Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Sign in to your Rockwell Automation account to view and download technical drawings.
Sign In
Documents
Installation Instructions General
1606-IN001
Product Cutsheet General
--
1606-td002_-en-p Technical Data
1606-TD002
Type Resource Publication
General Installation Instructions 1606-IN001
General Product Cutsheet --
Technical Data 1606-td002_-en-p 1606-TD002
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Certifications
Australian RCM UL Listed ATEX IECEx Scheme Korean KC China CCC Eurasion Economic Community
  • Australian RCM
  • UL Listed
  • ATEX
  • IECEx Scheme
  • Korean KC
  • China CCC
  • DNV-GL
  • CE
  • Eurasion Economic Community

This product was certified with the above certifications as of 2025-09-09. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Accessories
Items Per Page:
1-1 of 1
Alternative Products
Items Per Page:
1-1 of 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading
Find your nearest distributor
Contact your distributor in {0}
Change location
EmailEmail
PhonePhone
Find a partner
XLE Power Supply 120W 24VDC 5A
CloseClose
1606-XLE120E
Close
Print
Chevron LeftChevron Left
Allen-Bradley 1606-XLE120E product image
Chevron LeftChevron Left
Allen-Bradley 1606-XLE120E product image
Allen-Bradley 1606-XLE120E product image
Phone:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
Sign in to your Rockwell Automation account to submit a repair documentation request.
Sign In
Request repair documentation
All fields with * are required for processing your request.
This field is required
This field is required
This field is required
This field is required
This field is required
Documentation of liability insurance is required for anyone who is requesting documentation for product repairs.
UploadUpload
Please upload documentation of liability insurance.*
1 file selected
CloseClose
File size is too large. Must be less than 5 MB.
Accepted file types: zip, pdf; Maximum size: 5 MB.
Right to Repair Terms and Conditions
Rockwell Automation is making, parts, and service documentation available at your request in compliance with applicable right to repair laws and regulations. By signing below, you are agreeing to the following terms and conditions of your purchase of Rockwell Automation genuine repair parts for repair of a Rockwell Automation product. As used below, “Self Service Repair Parts” means genuine Rockwell Automation parts (components of Rockwell Automation products) purchased from Rockwell Automation for installation in a Rockwell Automation product as part of a Self Service Repair. Self Service Repair Parts may be new or previously used genuine Rockwell Automation parts that have been tested and passed Rockwell Automation functional requirements. “Self Service Repair Tools” means equipment and related materials purchased for the purpose of performing repairs.
Your request has been successfully submitted.
Please allow up to 5 business days to receive a response to your inquiry.
  1. Chevron LeftChevron Left Rockwell Automation Home
  2. Chevron LeftChevron Left Products
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose