1494V-DHX622-A-E-FF
NEMA 200 A Flange Mtd Rod Switch
Rockwell Automation announces that as of May 31, 2019, the NEMA 200 A Flange Mtd Rod Switch will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
Discontinued Date:
May 31, 2019
Replacement Category:
No planned RA replacement
Rockwell Automation announces that as of May 31, 2019, the NEMA 200 A Flange Mtd Rod Switch will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
Discontinued Date:
May 31, 2019
Replacement Category:
No planned RA replacement
| Sub Brand |
NEMA
|
|---|
| Number of auxiliary contacts as normally open contact |
2
|
|---|---|
| Rated permanent current Iu |
200 A
|
| Max. rated operation voltage Ue AC |
600 V
|
| Type of control element |
Long turning handle
|
| Switching frequency, max |
5 ops/m
|
| Fuse clip type |
Class H fuse clips
|
| Continuous current rating |
200A @ 600V AC
|
| Number of switches |
1
|
| Motor drive integrated |
False
|
| Motor drive optional |
False
|
| Voltage release optional |
False
|
| Type of electrical connection of main circuit |
Screw connection
|
| Switch and fuse rating (fusing) |
600V 200 A switch, 200 A clips
|
| Short circuit withstand capability |
10000A @ 600V AC/DC: unfused or with Class H fuses
|
| KW rating, max |
90 Kw per AC23 (IEC) @ 380...440V AC, 3-phase, 50 Hz
|
| Hp rating, max |
60 Hp per UL and CSA @ 230V AC, 3-phase, 60 Hz
|
| Low level auxiliary contact rating 1 NO or 1 NC |
C300, R150 per NEMA/EEMAC
|
| Standard auxiliary contact rating 1 NO or 1 NC |
AC 15, DC 13 to IEC/EN60947-5-1 and UL 508, 17V @ 5mA minimum per IEC
|
| Factory installed models |
Long connecting rod
|
| Dielectric strength |
2200V @ 1min
|
| Standard electrical interlock contact rating 2 NO |
10A @ 250V AC, 0.3A @ 250V DC per NEMA/EEMAC
|
| Interlockable |
True
|
|---|---|
| Version as emergency stop installation |
False
|
| Recommended torque, lug to terminal |
175 in-lb
|
| Mechanical life operations |
8000 (typical)
|
| Version as safety switch |
False
|
| Version as reversing switch |
False
|
| Version as main switch |
True
|
| Version as maintenance-/service switch |
True
|
| Material |
Switches, mechanisms and accessory kits: zinc-plated steel, RoHS compliant finish
|
| Recommended torque, switch side |
275 in-lb
|
| Suitable for front mounting 4-hole |
False
|
|---|---|
| Suitable for front mounting centre |
False
|
| Colour control element |
Black
|
| Device construction |
Built-in device fixed built-in technique
|
| Disconnect mechanism |
Left-hand mechanism
|
| Suitable for floor mounting |
False
|
| Suitable for distribution board installation |
True
|
| Suitable for intermediate mounting |
True
|
| Conductor size |
#6...4 AWG (16...95 mm²)
|
| Altitude |
2000 m per IEC 337-1
|
|---|---|
| Relative humidity |
90% @ 20°C (68 °F) and 50% @ 40°C (104 °F)
|
| Ambient open temperature, max |
-20 °C
|
| Ambient enclosed temperature, max |
-20 °C
|
| Ambient storage temperature, max |
-40 °C
|
| Technical Data | Publication |
|---|---|
| 1494-td002_-en-p | 1494-TD002 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
| Technotes |
|---|
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
| Sub Brand |
NEMA
|
|---|
| Number of auxiliary contacts as normally open contact |
2
|
|---|---|
| Rated permanent current Iu |
200 A
|
| Max. rated operation voltage Ue AC |
600 V
|
| Type of control element |
Long turning handle
|
| Switching frequency, max |
5 ops/m
|
| Fuse clip type |
Class H fuse clips
|
| Continuous current rating |
200A @ 600V AC
|
| Number of switches |
1
|
| Motor drive integrated |
False
|
| Motor drive optional |
False
|
| Voltage release optional |
False
|
| Type of electrical connection of main circuit |
Screw connection
|
| Switch and fuse rating (fusing) |
600V 200 A switch, 200 A clips
|
| Short circuit withstand capability |
10000A @ 600V AC/DC: unfused or with Class H fuses
|
| KW rating, max |
90 Kw per AC23 (IEC) @ 380...440V AC, 3-phase, 50 Hz
|
| Hp rating, max |
60 Hp per UL and CSA @ 230V AC, 3-phase, 60 Hz
|
| Low level auxiliary contact rating 1 NO or 1 NC |
C300, R150 per NEMA/EEMAC
|
| Standard auxiliary contact rating 1 NO or 1 NC |
AC 15, DC 13 to IEC/EN60947-5-1 and UL 508, 17V @ 5mA minimum per IEC
|
| Factory installed models |
Long connecting rod
|
| Dielectric strength |
2200V @ 1min
|
| Standard electrical interlock contact rating 2 NO |
10A @ 250V AC, 0.3A @ 250V DC per NEMA/EEMAC
|
| Interlockable |
True
|
|---|---|
| Version as emergency stop installation |
False
|
| Recommended torque, lug to terminal |
175 in-lb
|
| Mechanical life operations |
8000 (typical)
|
| Version as safety switch |
False
|
| Version as reversing switch |
False
|
| Version as main switch |
True
|
| Version as maintenance-/service switch |
True
|
| Material |
Switches, mechanisms and accessory kits: zinc-plated steel, RoHS compliant finish
|
| Recommended torque, switch side |
275 in-lb
|
| Suitable for front mounting 4-hole |
False
|
|---|---|
| Suitable for front mounting centre |
False
|
| Colour control element |
Black
|
| Device construction |
Built-in device fixed built-in technique
|
| Disconnect mechanism |
Left-hand mechanism
|
| Suitable for floor mounting |
False
|
| Suitable for distribution board installation |
True
|
| Suitable for intermediate mounting |
True
|
| Conductor size |
#6...4 AWG (16...95 mm²)
|
| Altitude |
2000 m per IEC 337-1
|
|---|---|
| Relative humidity |
90% @ 20°C (68 °F) and 50% @ 40°C (104 °F)
|
| Ambient open temperature, max |
-20 °C
|
| Ambient enclosed temperature, max |
-20 °C
|
| Ambient storage temperature, max |
-40 °C
|
Documents
|
1494-td002_-en-p
Technical Data
1494-TD002 |
| Technical Data | Publication |
|---|---|
| 1494-td002_-en-p | 1494-TD002 |
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Alternative Products
Technotes
| Technotes |
|---|
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Copyright ©2026 Rockwell Automation, Inc.