Loading
View all 1444 Dynamix
Print
Share
QR code
JSON
  • alt text
alt text
Chevron LeftChevron Left
alt text
Chevron LeftChevron Left
Allen-Bradley logo
Preferred
1444-DYN04-01RA

Dynamic Measurement Module

Serial #:
This product has not been verified. Please {} to confirm authenticity. register your product
Lifecycle status: Active
Description
Dynamic Measurement Module
  • Add to BOM
  • Repair services
  • Get support
Preferred
1444-DYN04-01RA

Dynamic Measurement Module

Serial #:
This product has not been verified. Please {} to confirm authenticity. register your product
  • alt text
alt text
Chevron LeftChevron Left
alt text
Chevron LeftChevron Left
Allen-Bradley logo
Lifecycle status: Active
Description
Dynamic Measurement Module
  • Add to BOM
  • Repair services
  • Get support
Find your nearest distributor
Contact your distributor in {0}
Change location
PhonePhone
Find a partner
Find your nearest distributor
Contact your distributor in {0}
Change location
PhonePhone
Find a partner
Overview
Electrical & Connectivity
General Features
Power & Electrical Characteristics
Relays & Control Outputs
A/D Converter
Inputs & Outputs (I/O)
Communication & Interfaces
Technical Specifications
Measurement & Parameters
Alarms & Fault Management
Data Handling
Signal Processing & Conditioning
Compliance & Environment
Standards & Protection
Physical Characteristics
Construction
Mechanical
Module
Drawings
Documents
Downloads
Certifications
Alternative Products
Technotes
Unique Product Identifier
1444-DYN04-01RA
UPC
885630427027
Estimated Lead Time
87 days
Standard Warranty Duration

1 year See details

Country of Origin
United States of America
Buffer Outputs
4
Control Output
1 SPDT, +opt RELX (4 SPDT) x3
Interface
EtherNet/IP
Number Of Channels
4
Number of status indicators
16
Speed Inputs
2
Status indicator
Power, Module status, Network status, Processor status, Processor operating state, DSP status, DSP operating state, Channel status (4), Relay status, Ethernet link status (2), Ethernet activity indicator (2)
Transducer Power
IEPE Accel, ECP's, Volts
Conductor type
Copper
Connections
Terminal pin
Consumption
11.5 W
Current
411mA @ 24V (546...319mA @ 18...32V)
Dissipation
9 W
Ethernet
True
Isolation voltage
50V (continuous), basic insulation type between Ethernet, power, ground, and AUX bus, 50V (continuous), basic insulation type between signal ports, power, ground, and AUX bus, 250V (continuous), basic insulation type between relay ports and system, No
Model
Basic device
Number of connections
2
Number of indicator outputs
16
Number of sensor inputs for IEPE sensors
4
Power monitor
The two power supply voltage levels are monitored. status indicated via process operating status indicators and on controller input (I/O)
Redundant power
Two 18...32V DC, max 8 A SELV power supply inputs, Higher voltage supply is applied to main and expansion modules
Suitable for bus connection
True
Supply voltage
32V DC
Supply voltage DC
18 V
Type of electric connection
Spring clA connection
Voltage
North American: 18...32V, max 8 A, limited voltage source
Voltage type of supply voltage
DC
Wire type
Shielded on signal connections, Only Shielded on Ethernet ports, Unshielded on power and relay ports
Contact arrangement
Single pole double throw (SPDT) change-over contact
Contact material
Gold plated @ surface material
Electrical life cycles, min
50000
Faults
Main module fault, Main module tachom fault, Expansion module fault, Ethernet network fault, Expansion bus fault
Inductive load
5A @ 250V AC
Mechanical life operations, min
10000000
Number of relays
1
Operating time, max
15 ms @ rated voltage
Permissible load, min
10mA @ 5V DC
Rated carry current
8 A
Rated current, max
8 A AC
Rated voltage, max
250V AC
Releasing time, max
5 ms @ rated voltage
Resistive load
8A @ 250V AC
Switching capacity, max
90 W DC @ inductive load
Voted alarm
Assign to any enabled voted alarm (0...12)
Conversion
24 bit
Dynamic range
80 dBfs (0.01% fs), 90 dBfs typical
Sample rate
93 kS/s, 2 channels
Controller & System I/O
Alarm reset
Alarm gate control
Alarm status
Channel setup
Aux processor
DSP processor
Data speed
Alarm limits (16)
Relay status
Expansion module
Set point multiplier enable
Alarm buffer reset
Trend alarm
Transducer
Trip inhibit
Alarm buffer trigger
Input Signals
Detection threshold
Fixed (-2.5V DC)
Impedance
>100 kΩ
Isolation
Non-isolated, single-ended analog inputs. sensor signal returns must be isolated from ground
Local bus inputs
Opto-isolated TTL input for signal and TX status
Number of channel inputs
4
Number of digital inputs
2
Number of tachometer inputs
2
Protection
Reverse polarity
Sensor types
CP accelerom (CCS), Dynamic pressure transducers, Dual sensors (acceleration + temperature), Eddy current probe systems (-24V DC), Self-powered sensors, Voltage signals
Terminal inputs
TTL class with internal pull-up resistor (5V DC)
Transducer fault detection
Bias level high / low limits, Current threshold level monitoring, which is implemented in hardware for -24V supplied sensors. provides the fastest fault detection possible with excellent reliability.
Transducer negative power
Voltage regulated: -24V/25 mA
Transducer positive power
Voltage regulated: 24V/25 mA
Transducer status
Only local bus inputs
Voltage ranges
±24V DC
Output Signals
Application
Trip inhibit/bypass, Alarm/relay reset, Alarm SPM/gate control 0, 1, Tachom 0, 1 status
BNC
Surge protection: No
Notes
All outputs are single ended and have no isolation, Buffered output is not representative of input when no load (sensor) is connected to the associated measurement channel, Confirm that the connected instrumentation does not provide power, such as if to
Number of buffered outputs
4
Number of digital outputs
2
Terminal pins
Surge protection: No
Communication
A digital network that is used between a main module and its expansion modules is implemented on the local bus. Communication does not link main modules
Communication protocol
ODVA-compliant (conformance tested) EtherNet/IP industrial protocol
Concurrent access
Controller (owner), Up to 3 (more) sessions
IP address
Set by hardware switch on the terminal base as 192.168.0.xxx (last octet set by switch), Set in configuration using DHCP/BOOTP tools
Power
Passes power from each main module (1444-DYN04-01RA) to its expansion modules, Power is not passed between main modules, When redundant power supplies are connected to a main module, only the voted power source is distributed to its expansion modules.
Supported connectivity protocols
Single Ethernet (IEEE 802.3), Device Level Ring (ODVA)
TTL signals
Dual independent TTL signals, with tachom sensor status, are passed on the Local Bus, There can be only one tachom expansion module on a local bus, The TTL signal can serve up to six main modules
Measurement Modes & Configuration
ADC out
Signal out of the ADC
Alternate path
Alternate signal path
Four channel dynamic (4 kHz)
Dual path: Measurement is the same as “four channel dynamic (4 kHz) or static, Inputs are internally connected between channels 0 and 2 and between channels 1 and 3
Four channel dynamic (4 kHz) or static
All channels are available. Each channel pair can be defined for either Static (DC) or Dynamic (AC) measurements, Dynamic channels can be configured for an FMAX up to 4578 Hz (274.7 kCPM)
Mid filter
Before high pass filter and integration
Multiplexed
Configuration dependent
Post filter
After high pass filter and integration
Two channel dynamic (20 kHz)
2 channel static: channels 0 and 1 can be configured for Dynamic (AC) measurements with an FMAX of up to 20.6 kHz (1236 kCPM), Channels 2 and 3 available for Static (DC) measurements.
Two channel dynamic (40 kHz)
Channels 0 and 1 (pair) can be configured for Dynamic (AC) measurements with a measurement span of 40 kHz (1), or as gSE. Channels 2 and 3 are disabled (off).
Measurement Types & Capabilities
Bias/gap
Number per channel: 1
DC measurement types
Proportional voltage
Data format
32-bit float
Data source
Selectable: post filter, mid filter, alternate path
FFT
Windows: none, flat top, hamming, hanning
FFT bands
Order domain speed ref: 0, 1
Measurement type
Rod drop
Not 1x
Number per channel: 1
Overall
Time constant
Real time
500 ms (typical)
SMAX
Per channel pair
Shaft absolute
Per channel pair
Time waveform
SAle rate: ≤Fmax
Tracking filters
Roll Off: -48 dB/octave
Trigger source
Speed reference: 0 or 1
Type
TTL class
gSE FFT
Number per channel: 1
gSE overall
Number per channel: 1
Speed Measurement
Mode
Redundant: Speed 0 = Speed 1 when tach 0 in fault
Speed
Terminal pin: TTL
Speed acceleration
Update rate: 1 / s
Speed, max
1 per speed measurement, Maximum speed since reset, Reset via controller I/O,
Timing & Synchronization
Accuracy
Maximum drift: 100 ms per year
Synchronization
Clock synchronized to controller time per IEEE-1588 V2 / CIP sync (ODVA) standard
Alarms
Alarm form
Over/under threshold
Alarm logic
1oo1, 1oo2, 2oo2, 1oo3, 2oo3, 3oo3, 1oo4, 2oo4, 3oo4, 4oo4, 1oo2 AND 1oo2. 2oo2 OR 2oo2,1oo2 AND 2oo2, 2oo2 AND 1oo2
Deadband
0 %
Delay times
Separate delay times for alert and danger alarms
Failsafe
If assigned to a relay, when in alarm the relay coil is deenergized
High-resolution samples
SAled rate: 100 ms
I/O gating control
Alarm is evaluated when gate condition is true, Control on either of two controller output (I/O) bit, Control on either of two digital inputs (hardware)
I/O logix control
Alarm actuates when logic control is set, Control on either of two controller output (I/O) bit, Control on either of two digital inputs (hardware)
Input condition
Alert, Danger, Transducer fault
Input parameter
Any real-time or discrete continuous measurement
Latching
Non-latching, resets when condition clears, Latching, after condition clears, resets upon command via controller I/O
Logic inputs
1...4 measurement alarms
Number
Voted alarms: 13
Processing mode
Profile: limits that are read from controller I/O
SPM control source
Controller I/O SPM control bit 0 or 1/digital input 0 or 1
SPM timer
Number of s the SPM is applied after SPM signal is reset, From 0...65.5 s in 0.1 s increments
Saved trend buffer
640 static records: includes N% records sAled post trigger
Set point multiplier range: 0.1...100x
Multiply the threshold limits by this value when invoked. Can be static: enabled by controller I/O or manual switch
Speed gating control
Speed reference: 0, 1, Condition (>, <, <>, ><), Speed limits (low, high)
Sustain time
1.0 s (fixed)
Transducer state consideration
OK required, Not OK forces alarm, OK status is not considered
Fault Management
Controller I/O
Status bit on controller input table
Expansion bus link time-out
100 ms (fixed)
Indication
Update status indicator
Relay action
Select fault on any of Module, Select fault on any of Expansion module, Select fault on any of Ethernet, Select fault on any of Expansion bus
Data
Buffers
Four buffers each containing: 640 discrete records, 64 dynamic records
Definition
Speed Source: 0.1, Transient minimum, Transient maximum speed, Startup: speed increases from under to over the maximum speed, Coastdown: speed decreases from over to under the maximum speed
Dynamic data
SAle rate(1): N x 100 ms
Enable
Enable static data capture, Enable dynamic data capture
Overflow
When enabled allows buffers of up to 2560 discrete and 256 dynamic records
Record content
Dynamic data: TWF and FFT per channel
Sample Intervals
At delta RPM (off or 1...1000 RPM), At delta time (off or ≥ 1 s), Post start-up time, Dynamic records are captured every tenth trigger
Static data
SAle rate: N x 100 Ms
Logging
Conditions
35 logged conditions, Categorized by event type
Event types
System, Alarm, Buffer
Number of entries
1500 total records, 256 records per event type
Time stamp resolution
0.1 ms
Absolute shaft
Per channel pair, Ch-0/2: displacement, Ch-1/3: acceleration or velocity, Relative mounting: 0°, 180°
Asynchronous mode FMAX
30 Hz
Bandwidth FMAX
0.035 khz
Frequency, max
Surveillance: 40 kHz (OA only)
High pass filter
-3 dB corner: 0.1 Hz to 1 kHz, -24, -60 dB/octave
Integration
None, single or double
Low pass filter
-3 dB corner 10 Hz to 40 kHz, -24, -60 dB/octave
Resolution
3 µV (theoretical)
Sampling mode
Synchronous
Signal detection
Peak to peak, Peak, RMS, Calculated peak to peak, Calculated peak
Synchronous mode
Tachom source: 0, 1, SAles per rev: 8...128, Orders: 2.0...31.3
gSE
2 gSE channels max, Only 2-channel protection or surveillance modes, Overall, only TWF/FFT, HPF: 200, 500 Hz, 1, 2, 5 kHz, FFT FMAX: 100 Hz...5 kHz
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Conductor/insulation temperature rating, min
85 °C
Conformal coating
All printed circuit boards are conformal coated in accordance with IPC-A-610C and in compliance with: IPC-CC-830 B, UL508
EFT/B immunity
±2kV @ 5kHz on unshielded power ports, ±2kV @ 5kHz on shielded signal ports, ±2kV @ 5kHz on shielded Ethernet ports, ±3kV @ 5kHz on unshielded relay ports
ESD immunity
6 kV contact discharges, 8 kV air discharges
Emissions
IEC 61000-6-4
Nonoperating temperature
-40 °C
Operating temperature
-25 °C
Operating temperature (screw type only), max
115 °C
Operating temperature (spring type only), max
105 °C
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Relative humidity
5...95% noncondensing
Shock
Operating: 15 G
Surge transient immunity
±1 kV line-line(DM) and ±2 kV line-earth(CM) on unshielded power and relay ports, ±2 kV line-earth(CM) on shielded signal ports, ±2 kV line-earth(CM) on shielded Ethernet ports
Surrounding air temperature, max
70 °C
Vibration
2.0 G @ 10…500 Hz
Construction
Depth
Without terminal base: 154 mm (6.06 in)
Enclosure type rating
None (open-style)
Height
Without terminal base: 106 mm (4.17 in)
Modular expandable
True
Number of rotational speed inputs
2
Type of fastening
DIN rail (top hat rail)
Width
Without terminal base: 102 mm (4.02 in)
Mechanical
Conductor UL/cUL AWG (screw type only)
0.05 mm²
Conductor UL/cUL AWG (spring type only)
0.08 mm²
Conductor UL/cUL AWG (spring type only), max
1.5 mm²
Conductor cross section AWG/kcmil
0.08
Conductor cross section solid or stranded
0.14
Conductor crosssection stranded with ferrule with plastic sleeve
0.25
Conductor crosssection stranded with ferrule without plastic sleeve
0.25
Stripping length
9 mm
Torque (screw type only)
0.22 nm
Weight
Without terminal base: 0.40 kg (0.88 lb)
Construction
Wiring category
2 - on signal ports, 2 - on power ports, 2 - on communications ports, 1 - on relay ports
Drawings
3D Dimension Drawings(STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3D Dimension Drawings(STP) Download (ZIP)
Product Drawing Drawing (DXF)
General Publication
Product Cutsheet --
Technical Data Publication
1444-td001_-en-p 1444-TD001
User Manual Publication
1444-um001_-en-p 1444-UM001
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Search the Literature Library
Version:
Product DocumentationProduct Documentation Release notes
Accessory Files Size Notes
Condition Monitoring Device Library v1.01.00 568 MB
Condition Monitoring Device Library v1.01.00 568 MB
Firmware Size Notes
Firmware for 1444-DYN04-01RA v4.011 532 KB
Firmware for 1444-DYN04-01RA v4.007 701 KB
Firmware for Dynamix 1444-DYN04-01RA v3.002 594 KB
AOP - Add On Profiles Size Notes
AOP - Add On Profiles for 1444-DYN04-01RA v2.1.45 219 MB Product DocumentationProduct Documentation Release notes
AOP for 1444 Dynamix Condition Monitor Module v.1.02.05 436 MB Product DocumentationProduct Documentation Release notes
EDS - Electronic Data Sheet Files Size Notes
EDS files for 1444-DYN04-01RA (multi) 8.95 KB
EDS files for EtherNet/IP Family (multi) 6.27 MB
EDS files for 1444-DYN04-01RA (multi) 8.95 KB
EDS files for EtherNet/IP Family (multi) 6.27 MB
Condition Monitoring Device Library v1.01.00 Accessory Files 568 MB
Condition Monitoring Device Library v1.01.00 Accessory Files 568 MB
Firmware for 1444-DYN04-01RA v4.011 Firmware 532 KB
Firmware for 1444-DYN04-01RA v4.007 Firmware 701 KB
Firmware for Dynamix 1444-DYN04-01RA v3.002 Firmware 594 KB
AOP - Add On Profiles for 1444-DYN04-01RA v2.1.45 AOP - Add On Profiles 219 MB Product DocumentationProduct Documentation Release notes
AOP for 1444 Dynamix Condition Monitor Module v.1.02.05 AOP - Add On Profiles 436 MB Product DocumentationProduct Documentation Release notes
EDS files for 1444-DYN04-01RA (multi) EDS - Electronic Data Sheet Files 8.95 KB
EDS files for EtherNet/IP Family (multi) EDS - Electronic Data Sheet Files 6.27 MB
EDS files for 1444-DYN04-01RA (multi) EDS - Electronic Data Sheet Files 8.95 KB
EDS files for EtherNet/IP Family (multi) EDS - Electronic Data Sheet Files 6.27 MB
Looking for more Downloads?
Find product downloads in Rockwell Automation Product Compatibility and Download Center.
Search PCDC
China CCC IECEx Scheme ATEX
  • China CCC
  • IECEx Scheme
  • ATEX
  • MOROCCO DOC
  • UK EX CERTIFICATE

This product was certified with the above certifications as of 2026-08-11. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Looking for certification documents?
Explore certifications for this product and more in our comprehensive Literature Library.

Search the Literature Library
Regulatory Information
EU Importer Address

Rockwell Automation N.V
Pegasus Park
De Kleetlaan 12A
1831 Diegem
Belgium

EU Authorized Representative Address

Rockwell Automation N.V
Pegasus Park
De Kleetlaan 12A
1831 Diegem
Belgium

Items Per Page:
1-1 of 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Overview
Unique Product Identifier
1444-DYN04-01RA
UPC
885630427027
Estimated Lead Time
87 days
Standard Warranty Duration

1 year See details

Country of Origin
United States of America
Electrical & Connectivity
Buffer Outputs
4
Control Output
1 SPDT, +opt RELX (4 SPDT) x3
Interface
EtherNet/IP
Number Of Channels
4
Number of status indicators
16
Speed Inputs
2
Status indicator
Power, Module status, Network status, Processor status, Processor operating state, DSP status, DSP operating state, Channel status (4), Relay status, Ethernet link status (2), Ethernet activity indicator (2)
Transducer Power
IEPE Accel, ECP's, Volts
Conductor type
Copper
Connections
Terminal pin
Consumption
11.5 W
Current
411mA @ 24V (546...319mA @ 18...32V)
Dissipation
9 W
Ethernet
True
Isolation voltage
50V (continuous), basic insulation type between Ethernet, power, ground, and AUX bus, 50V (continuous), basic insulation type between signal ports, power, ground, and AUX bus, 250V (continuous), basic insulation type between relay ports and system, No
Model
Basic device
Number of connections
2
Number of indicator outputs
16
Number of sensor inputs for IEPE sensors
4
Power monitor
The two power supply voltage levels are monitored. status indicated via process operating status indicators and on controller input (I/O)
Redundant power
Two 18...32V DC, max 8 A SELV power supply inputs, Higher voltage supply is applied to main and expansion modules
Suitable for bus connection
True
Supply voltage
32V DC
Supply voltage DC
18 V
Type of electric connection
Spring clA connection
Voltage
North American: 18...32V, max 8 A, limited voltage source
Voltage type of supply voltage
DC
Wire type
Shielded on signal connections, Only Shielded on Ethernet ports, Unshielded on power and relay ports
Contact arrangement
Single pole double throw (SPDT) change-over contact
Contact material
Gold plated @ surface material
Electrical life cycles, min
50000
Faults
Main module fault, Main module tachom fault, Expansion module fault, Ethernet network fault, Expansion bus fault
Inductive load
5A @ 250V AC
Mechanical life operations, min
10000000
Number of relays
1
Operating time, max
15 ms @ rated voltage
Permissible load, min
10mA @ 5V DC
Rated carry current
8 A
Rated current, max
8 A AC
Rated voltage, max
250V AC
Releasing time, max
5 ms @ rated voltage
Resistive load
8A @ 250V AC
Switching capacity, max
90 W DC @ inductive load
Voted alarm
Assign to any enabled voted alarm (0...12)
Conversion
24 bit
Dynamic range
80 dBfs (0.01% fs), 90 dBfs typical
Sample rate
93 kS/s, 2 channels
Controller & System I/O
Alarm reset
Alarm gate control
Alarm status
Channel setup
Aux processor
DSP processor
Data speed
Alarm limits (16)
Relay status
Expansion module
Set point multiplier enable
Alarm buffer reset
Trend alarm
Transducer
Trip inhibit
Alarm buffer trigger
Input Signals
Detection threshold
Fixed (-2.5V DC)
Impedance
>100 kΩ
Isolation
Non-isolated, single-ended analog inputs. sensor signal returns must be isolated from ground
Local bus inputs
Opto-isolated TTL input for signal and TX status
Number of channel inputs
4
Number of digital inputs
2
Number of tachometer inputs
2
Protection
Reverse polarity
Sensor types
CP accelerom (CCS), Dynamic pressure transducers, Dual sensors (acceleration + temperature), Eddy current probe systems (-24V DC), Self-powered sensors, Voltage signals
Terminal inputs
TTL class with internal pull-up resistor (5V DC)
Transducer fault detection
Bias level high / low limits, Current threshold level monitoring, which is implemented in hardware for -24V supplied sensors. provides the fastest fault detection possible with excellent reliability.
Transducer negative power
Voltage regulated: -24V/25 mA
Transducer positive power
Voltage regulated: 24V/25 mA
Transducer status
Only local bus inputs
Voltage ranges
±24V DC
Output Signals
Application
Trip inhibit/bypass, Alarm/relay reset, Alarm SPM/gate control 0, 1, Tachom 0, 1 status
BNC
Surge protection: No
Notes
All outputs are single ended and have no isolation, Buffered output is not representative of input when no load (sensor) is connected to the associated measurement channel, Confirm that the connected instrumentation does not provide power, such as if to
Number of buffered outputs
4
Number of digital outputs
2
Terminal pins
Surge protection: No
Communication
A digital network that is used between a main module and its expansion modules is implemented on the local bus. Communication does not link main modules
Communication protocol
ODVA-compliant (conformance tested) EtherNet/IP industrial protocol
Concurrent access
Controller (owner), Up to 3 (more) sessions
IP address
Set by hardware switch on the terminal base as 192.168.0.xxx (last octet set by switch), Set in configuration using DHCP/BOOTP tools
Power
Passes power from each main module (1444-DYN04-01RA) to its expansion modules, Power is not passed between main modules, When redundant power supplies are connected to a main module, only the voted power source is distributed to its expansion modules.
Supported connectivity protocols
Single Ethernet (IEEE 802.3), Device Level Ring (ODVA)
TTL signals
Dual independent TTL signals, with tachom sensor status, are passed on the Local Bus, There can be only one tachom expansion module on a local bus, The TTL signal can serve up to six main modules
Technical Specifications
Measurement Modes & Configuration
ADC out
Signal out of the ADC
Alternate path
Alternate signal path
Four channel dynamic (4 kHz)
Dual path: Measurement is the same as “four channel dynamic (4 kHz) or static, Inputs are internally connected between channels 0 and 2 and between channels 1 and 3
Four channel dynamic (4 kHz) or static
All channels are available. Each channel pair can be defined for either Static (DC) or Dynamic (AC) measurements, Dynamic channels can be configured for an FMAX up to 4578 Hz (274.7 kCPM)
Mid filter
Before high pass filter and integration
Multiplexed
Configuration dependent
Post filter
After high pass filter and integration
Two channel dynamic (20 kHz)
2 channel static: channels 0 and 1 can be configured for Dynamic (AC) measurements with an FMAX of up to 20.6 kHz (1236 kCPM), Channels 2 and 3 available for Static (DC) measurements.
Two channel dynamic (40 kHz)
Channels 0 and 1 (pair) can be configured for Dynamic (AC) measurements with a measurement span of 40 kHz (1), or as gSE. Channels 2 and 3 are disabled (off).
Measurement Types & Capabilities
Bias/gap
Number per channel: 1
DC measurement types
Proportional voltage
Data format
32-bit float
Data source
Selectable: post filter, mid filter, alternate path
FFT
Windows: none, flat top, hamming, hanning
FFT bands
Order domain speed ref: 0, 1
Measurement type
Rod drop
Not 1x
Number per channel: 1
Overall
Time constant
Real time
500 ms (typical)
SMAX
Per channel pair
Shaft absolute
Per channel pair
Time waveform
SAle rate: ≤Fmax
Tracking filters
Roll Off: -48 dB/octave
Trigger source
Speed reference: 0 or 1
Type
TTL class
gSE FFT
Number per channel: 1
gSE overall
Number per channel: 1
Speed Measurement
Mode
Redundant: Speed 0 = Speed 1 when tach 0 in fault
Speed
Terminal pin: TTL
Speed acceleration
Update rate: 1 / s
Speed, max
1 per speed measurement, Maximum speed since reset, Reset via controller I/O,
Timing & Synchronization
Accuracy
Maximum drift: 100 ms per year
Synchronization
Clock synchronized to controller time per IEEE-1588 V2 / CIP sync (ODVA) standard
Alarms
Alarm form
Over/under threshold
Alarm logic
1oo1, 1oo2, 2oo2, 1oo3, 2oo3, 3oo3, 1oo4, 2oo4, 3oo4, 4oo4, 1oo2 AND 1oo2. 2oo2 OR 2oo2,1oo2 AND 2oo2, 2oo2 AND 1oo2
Deadband
0 %
Delay times
Separate delay times for alert and danger alarms
Failsafe
If assigned to a relay, when in alarm the relay coil is deenergized
High-resolution samples
SAled rate: 100 ms
I/O gating control
Alarm is evaluated when gate condition is true, Control on either of two controller output (I/O) bit, Control on either of two digital inputs (hardware)
I/O logix control
Alarm actuates when logic control is set, Control on either of two controller output (I/O) bit, Control on either of two digital inputs (hardware)
Input condition
Alert, Danger, Transducer fault
Input parameter
Any real-time or discrete continuous measurement
Latching
Non-latching, resets when condition clears, Latching, after condition clears, resets upon command via controller I/O
Logic inputs
1...4 measurement alarms
Number
Voted alarms: 13
Processing mode
Profile: limits that are read from controller I/O
SPM control source
Controller I/O SPM control bit 0 or 1/digital input 0 or 1
SPM timer
Number of s the SPM is applied after SPM signal is reset, From 0...65.5 s in 0.1 s increments
Saved trend buffer
640 static records: includes N% records sAled post trigger
Set point multiplier range: 0.1...100x
Multiply the threshold limits by this value when invoked. Can be static: enabled by controller I/O or manual switch
Speed gating control
Speed reference: 0, 1, Condition (>, <, <>, ><), Speed limits (low, high)
Sustain time
1.0 s (fixed)
Transducer state consideration
OK required, Not OK forces alarm, OK status is not considered
Fault Management
Controller I/O
Status bit on controller input table
Expansion bus link time-out
100 ms (fixed)
Indication
Update status indicator
Relay action
Select fault on any of Module, Select fault on any of Expansion module, Select fault on any of Ethernet, Select fault on any of Expansion bus
Data
Buffers
Four buffers each containing: 640 discrete records, 64 dynamic records
Definition
Speed Source: 0.1, Transient minimum, Transient maximum speed, Startup: speed increases from under to over the maximum speed, Coastdown: speed decreases from over to under the maximum speed
Dynamic data
SAle rate(1): N x 100 ms
Enable
Enable static data capture, Enable dynamic data capture
Overflow
When enabled allows buffers of up to 2560 discrete and 256 dynamic records
Record content
Dynamic data: TWF and FFT per channel
Sample Intervals
At delta RPM (off or 1...1000 RPM), At delta time (off or ≥ 1 s), Post start-up time, Dynamic records are captured every tenth trigger
Static data
SAle rate: N x 100 Ms
Logging
Conditions
35 logged conditions, Categorized by event type
Event types
System, Alarm, Buffer
Number of entries
1500 total records, 256 records per event type
Time stamp resolution
0.1 ms
Absolute shaft
Per channel pair, Ch-0/2: displacement, Ch-1/3: acceleration or velocity, Relative mounting: 0°, 180°
Asynchronous mode FMAX
30 Hz
Bandwidth FMAX
0.035 khz
Frequency, max
Surveillance: 40 kHz (OA only)
High pass filter
-3 dB corner: 0.1 Hz to 1 kHz, -24, -60 dB/octave
Integration
None, single or double
Low pass filter
-3 dB corner 10 Hz to 40 kHz, -24, -60 dB/octave
Resolution
3 µV (theoretical)
Sampling mode
Synchronous
Signal detection
Peak to peak, Peak, RMS, Calculated peak to peak, Calculated peak
Synchronous mode
Tachom source: 0, 1, SAles per rev: 8...128, Orders: 2.0...31.3
gSE
2 gSE channels max, Only 2-channel protection or surveillance modes, Overall, only TWF/FFT, HPF: 200, 500 Hz, 1, 2, 5 kHz, FFT FMAX: 100 Hz...5 kHz
Compliance & Environment
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Conductor/insulation temperature rating, min
85 °C
Conformal coating
All printed circuit boards are conformal coated in accordance with IPC-A-610C and in compliance with: IPC-CC-830 B, UL508
EFT/B immunity
±2kV @ 5kHz on unshielded power ports, ±2kV @ 5kHz on shielded signal ports, ±2kV @ 5kHz on shielded Ethernet ports, ±3kV @ 5kHz on unshielded relay ports
ESD immunity
6 kV contact discharges, 8 kV air discharges
Emissions
IEC 61000-6-4
Nonoperating temperature
-40 °C
Operating temperature
-25 °C
Operating temperature (screw type only), max
115 °C
Operating temperature (spring type only), max
105 °C
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Relative humidity
5...95% noncondensing
Shock
Operating: 15 G
Surge transient immunity
±1 kV line-line(DM) and ±2 kV line-earth(CM) on unshielded power and relay ports, ±2 kV line-earth(CM) on shielded signal ports, ±2 kV line-earth(CM) on shielded Ethernet ports
Surrounding air temperature, max
70 °C
Vibration
2.0 G @ 10…500 Hz
Physical Characteristics
Construction
Depth
Without terminal base: 154 mm (6.06 in)
Enclosure type rating
None (open-style)
Height
Without terminal base: 106 mm (4.17 in)
Modular expandable
True
Number of rotational speed inputs
2
Type of fastening
DIN rail (top hat rail)
Width
Without terminal base: 102 mm (4.02 in)
Mechanical
Conductor UL/cUL AWG (screw type only)
0.05 mm²
Conductor UL/cUL AWG (spring type only)
0.08 mm²
Conductor UL/cUL AWG (spring type only), max
1.5 mm²
Conductor cross section AWG/kcmil
0.08
Conductor cross section solid or stranded
0.14
Conductor crosssection stranded with ferrule with plastic sleeve
0.25
Conductor crosssection stranded with ferrule without plastic sleeve
0.25
Stripping length
9 mm
Torque (screw type only)
0.22 nm
Weight
Without terminal base: 0.40 kg (0.88 lb)
Construction
Wiring category
2 - on signal ports, 2 - on power ports, 2 - on communications ports, 1 - on relay ports
Drawings
Drawings
3D Dimension Drawings(STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3D Dimension Drawings(STP) Download (ZIP)
Product Drawing Drawing (DXF)
Documents
Product Cutsheet General
--
1444-td001_-en-p Technical Data
1444-TD001
1444-um001_-en-p User Manual
1444-UM001
General Publication
Product Cutsheet --
Technical Data Publication
1444-td001_-en-p 1444-TD001
User Manual Publication
1444-um001_-en-p 1444-UM001
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Search the Literature Library
Downloads
Version:
Product DocumentationProduct Documentation Release notes
Accessory Files Size Notes
Condition Monitoring Device Library v1.01.00 568 MB
Condition Monitoring Device Library v1.01.00 568 MB
Firmware Size Notes
Firmware for 1444-DYN04-01RA v4.011 532 KB
Firmware for 1444-DYN04-01RA v4.007 701 KB
Firmware for Dynamix 1444-DYN04-01RA v3.002 594 KB
AOP - Add On Profiles Size Notes
AOP - Add On Profiles for 1444-DYN04-01RA v2.1.45 219 MB Product DocumentationProduct Documentation Release notes
AOP for 1444 Dynamix Condition Monitor Module v.1.02.05 436 MB Product DocumentationProduct Documentation Release notes
EDS - Electronic Data Sheet Files Size Notes
EDS files for 1444-DYN04-01RA (multi) 8.95 KB
EDS files for EtherNet/IP Family (multi) 6.27 MB
EDS files for 1444-DYN04-01RA (multi) 8.95 KB
EDS files for EtherNet/IP Family (multi) 6.27 MB
Condition Monitoring Device Library v1.01.00 Accessory Files 568 MB
Condition Monitoring Device Library v1.01.00 Accessory Files 568 MB
Firmware for 1444-DYN04-01RA v4.011 Firmware 532 KB
Firmware for 1444-DYN04-01RA v4.007 Firmware 701 KB
Firmware for Dynamix 1444-DYN04-01RA v3.002 Firmware 594 KB
AOP - Add On Profiles for 1444-DYN04-01RA v2.1.45 AOP - Add On Profiles 219 MB Product DocumentationProduct Documentation Release notes
AOP for 1444 Dynamix Condition Monitor Module v.1.02.05 AOP - Add On Profiles 436 MB Product DocumentationProduct Documentation Release notes
EDS files for 1444-DYN04-01RA (multi) EDS - Electronic Data Sheet Files 8.95 KB
EDS files for EtherNet/IP Family (multi) EDS - Electronic Data Sheet Files 6.27 MB
EDS files for 1444-DYN04-01RA (multi) EDS - Electronic Data Sheet Files 8.95 KB
EDS files for EtherNet/IP Family (multi) EDS - Electronic Data Sheet Files 6.27 MB
Looking for more Downloads?
Find product downloads in Rockwell Automation Product Compatibility and Download Center.
Search PCDC
Certifications
{name=China CCC, link=http://literature.rockwellautomation.com/idc/groups/literature/documents/ct/1444-ct011_-en-e.pdf} {name=IECEx Scheme, link=http://literature.rockwellautomation.com/idc/groups/literature/documents/ct/1444-ct016_-en-e.pdf} {name=ATEX, link=http://literature.rockwellautomation.com/idc/groups/literature/documents/ct/1444-ct015_-en-e.pdf}
  • China CCC
  • IECEx Scheme
  • ATEX
  • MOROCCO DOC
  • UK EX CERTIFICATE

This product was certified with the above certifications as of 2026-08-11. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Looking for certification documents?
Explore certifications for this product and more in our comprehensive Literature Library.

Search the Literature Library
Regulatory Information
EU Importer Address

Rockwell Automation N.V
Pegasus Park
De Kleetlaan 12A
1831 Diegem
Belgium

EU Authorized Representative Address

Rockwell Automation N.V
Pegasus Park
De Kleetlaan 12A
1831 Diegem
Belgium

Alternative Products
Items Per Page:
1-1 of 1
Technotes
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
InformationInformation
Multiple countries of origin based on manufacturing location
Dynamic Measurement Module
CloseClose
1444-DYN04-01RA
Close
Print
Phone:
Call
InformationInformation

Please review your distributor selection

Choose distributor
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
Environmental compliance inquiry
All fields with * are required.
This field is required
This field is required
This field is required
This field is required
This field is required
This field is required
Your inquiry has been successfully submitted.
Please allow up to 5 business days to receive a response to your inquiry.
You can now close this window.
There was an error submitting your inquiry.
Please try again.
Sign in to your Rockwell Automation account to submit a repair documentation request.
Sign In
Request repair documentation
All fields with * are required for processing your request.
Please enter your business email address
This field is required
This field is required
This field is required
This field is required
Documentation of liability insurance is required for anyone who is requesting documentation for product repairs.
UploadUpload
Please upload documentation of Liability Insurance, Professional Establishment, and Technical Competence for the applicable EU Member Country.*
Accepted file types: zip, pdf. Max file size: 5 MB. Limit 3 files.
CloseClose
File size is too large. Must be less than 5 MB.
File limit exceeded. Maximum 3 files allowed.
This field is required
Right to Repair Terms and Conditions
Rockwell Automation is making, parts, and service documentation available at your request in compliance with applicable right to repair laws and regulations. By signing below, you are agreeing to the following terms and conditions of your purchase of Rockwell Automation genuine repair parts for repair of a Rockwell Automation product. As used below, “Self Service Repair Parts” means genuine Rockwell Automation parts (components of Rockwell Automation products) purchased from Rockwell Automation for installation in a Rockwell Automation product as part of a Self Service Repair. Self Service Repair Parts may be new or previously used genuine Rockwell Automation parts that have been tested and passed Rockwell Automation functional requirements. “Self Service Repair Tools” means equipment and related materials purchased for the purpose of performing repairs.
This field is required
Your request has been successfully submitted.
Please allow up to 5 business days to receive a response to your inquiry.
You can now close this window.
This catalog number is not currently eligible, please check the number you have entered or learn more about our repair services offered.
  1. Chevron LeftChevron Left Rockwell Automation Home
  2. Chevron LeftChevron Left Products
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose