Technical Specifications
General
Electrical
Construction
Environmental
Certification
Relay
Static (DC) Measurements
A/D Converter
Alarm Buffer
Measurement Alarms
Speed Measurement Specifications
Trend Buffer
Channel Inputs
Signal Conditioning
Inputs
Demand Measurement
Trend and Alarm Capture
Continuous FFT Band Measurements
Measurements
Complex Measurement
Power
Mechanical
Real-Time Clock
Voted Alarms
Real-Time Measurement
Digital Inputs
Module
Buffered outputs
Relays Logic
Fault Management
Digital Outputs
Transient Capture
Module Personalities
Indicators
Local Bus Function
Tachometer Inputs
Event Log
Alternate Path Signal Conditioning
Controller Input Status Information
Primary Path Signal Conditioning
Controller Output
Measurement Data Sources
Communication
Special Dynamic Signal Conditioning
Conformal Coating
Drawings
Documents
Downloads
Certifications
Alternative Products
Technotes
Buffer Outputs
4
Control Output
1 SPDT, +opt RELX (4 SPDT) x3
Interface
EtherNet/IP
Number Of Channels
4
Speed Inputs
2
Transducer Power
IEPE Accel, ECP's, Volts
Number of sensor inputs for IEPE sensors
4
Number of indicator outputs
16
Type of electric connection
Spring clA connection
Ethernet
True
Voltage type of supply voltage
DC
Supply voltage DC
18 V
Suitable for bus connection
True
Model
Basic device
Supply voltage
32V DC
Conductor type
Copper
Wire type
Shielded on signal connections, Only Shielded on Ethernet ports, Unshielded on power and relay ports
Number of rotational speed inputs
2
Type of fastening
DIN rail (top hat rail)
Depth
Without terminal base: 154 mm (6.06 in)
Height
Without terminal base: 106 mm (4.17 in)
Width
Without terminal base: 102 mm (4.02 in)
Modular expandable
True
Enclosure type rating
None (open-style)
Surrounding air temperature, max
70 °C
Operating temperature
-25 °C
Emissions
IEC 61000-6-4
Vibration
2.0 G @ 10…500 Hz
Shock
Operating: 15 G
EFT/B immunity
±2kV @ 5kHz on unshielded power ports, ±2kV @ 5kHz on shielded signal ports, ±2kV @ 5kHz on shielded Ethernet ports, ±3kV @ 5kHz on unshielded relay ports
Surge transient immunity
±1 kV line-line(DM) and ±2 kV line-earth(CM) on unshielded power and relay ports, ±2 kV line-earth(CM) on shielded signal ports, ±2 kV line-earth(CM) on shielded Ethernet ports
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Conductor/insulation temperature rating, min
85 °C
Operating temperature (spring type only), max
105 °C
Operating temperature (screw type only), max
115 °C
Nonoperating temperature
-40 °C
Relative humidity
5...95% noncondensing
ESD immunity
6 kV contact discharges, 8 kV air discharges
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
North American temperature code
T4
With approval according to UL
True
IEC temperature code
T4
Rated current, max
8 A AC
Rated voltage, max
250V AC
Inductive load
5A @ 250V AC
Switching capacity, max
90 W DC @ inductive load
Resistive load
8A @ 250V AC
Rated carry current
8 A
Number of relays
1
Electrical life cycles, min
50000
Mechanical life operations, min
10000000
Permissible load, min
10mA @ 5V DC
Releasing time, max
5 ms @ rated voltage
Operating time, max
15 ms @ rated voltage
Contact material
Gold plated @ surface material
Contact arrangement
Single pole double throw (SPDT) change-over contact
Measurement type
Rod drop
DC measurement types
Proportional voltage
Trigger source
Speed reference: 0 or 1
Sample rate
93 kS/s, 2 channels
Conversion
24 bit
Dynamic range
80 dBfs (0.01% fs), 90 dBfs typical
High-resolution samples
SAled rate: 100 ms
Saved trend buffer
640 static records: includes N% records sAled post trigger
Alarm form
Over/under threshold
Delay times
Separate delay times for alert and danger alarms
Processing mode
Profile: limits that are read from controller I/O
Set point multiplier range: 0.1...100x
Multiply the threshold limits by this value when invoked. Can be static: enabled by controller I/O or manual switch
Deadband
0 %
Sustain time
1.0 s (fixed)
Input parameter
Any real-time or discrete continuous measurement
Transducer state consideration
OK required, Not OK forces alarm, OK status is not considered
Speed acceleration
Update rate: 1 / s
Mode
Redundant: Speed 0 = Speed 1 when tach 0 in fault
Speed
Terminal pin: TTL
Speed, max
1 per speed measurement, Maximum speed since reset, Reset via controller I/O,
Static data
SAle rate: N x 100 Ms
Dynamic data
SAle rate(1): N x 100 ms
Transducer positive power
Voltage regulated: 24V/25 mA
Number of channel inputs
4
Impedance
>100 kΩ
Transducer negative power
Voltage regulated: -24V/25 mA
Sensor types
CP accelerom (CCS), Dynamic pressure transducers, Dual sensors (acceleration + temperature), Eddy current probe systems (-24V DC), Self-powered sensors, Voltage signals
Transducer fault detection
Bias level high / low limits, Current threshold level monitoring, which is implemented in hardware for -24V supplied sensors. provides the fastest fault detection possible with excellent reliability.
Frequency, max
Surveillance: 40 kHz (OA only)
Resolution
3 µV (theoretical)
Sampling mode
Synchronous
Integration
None, single or double
Low pass filter
-3 dB corner 10 Hz to 40 kHz, -24, -60 dB/octave
Signal detection
Peak to peak, Peak, RMS, Calculated peak to peak, Calculated peak
Voltage ranges
±24V DC
Time waveform
SAle rate: ≤Fmax
Data source
Selectable: post filter, mid filter, alternate path
FFT
Windows: none, flat top, hamming, hanning
Record content
Dynamic data: TWF and FFT per channel
Enable
Enable static data capture, Enable dynamic data capture
FFT bands
Order domain speed ref: 0, 1
Type
TTL class
gSE FFT
Number per channel: 1
Data format
32-bit float
Voltage
North American: 18...32V, max 8 A, limited voltage source
Isolation voltage
50V (continuous), basic insulation type between Ethernet, power, ground, and AUX bus, 50V (continuous), basic insulation type between signal ports, power, ground, and AUX bus, 250V (continuous), basic insulation type between relay ports and system, No
Dissipation
9 W
Number of connections
2
Consumption
11.5 W
Connections
Terminal pin
Current
411mA @ 24V (546...319mA @ 18...32V)
Redundant power
Two 18...32V DC, max 8 A SELV power supply inputs, Higher voltage supply is applied to main and expansion modules
Power monitor
The two power supply voltage levels are monitored. status indicated via process operating status indicators and on controller input (I/O)
Weight
Without terminal base: 0.40 kg (0.88 lb)
Stripping length
9 mm
Conductor UL/cUL AWG (spring type only), max
1.5 mm²
Conductor cross section solid or stranded
0.14
Conductor crosssection stranded with ferrule without plastic sleeve
0.25
Conductor crosssection stranded with ferrule with plastic sleeve
0.25
Conductor cross section AWG/kcmil
0.08
Conductor UL/cUL AWG (screw type only)
0.05 mm²
Conductor UL/cUL AWG (spring type only)
0.08 mm²
Torque (screw type only)
0.22 nm
Accuracy
Maximum drift: 100 ms per year
Synchronization
Clock synchronized to controller time per IEEE-1588 V2 / CIP sync (ODVA) standard
Failsafe
If assigned to a relay, when in alarm the relay coil is deenergized
Latching
Non-latching, resets when condition clears, Latching, after condition clears, resets upon command via controller I/O
Number
Voted alarms: 13
Logic inputs
1...4 measurement alarms
Input condition
Alert, Danger, Transducer fault
SPM control source
Controller I/O SPM control bit 0 or 1/digital input 0 or 1
Speed gating control
Speed reference: 0, 1, Condition (>, <, <>, ><), Speed limits (low, high)
SPM timer
Number of s the SPM is applied after SPM signal is reset, From 0...65.5 s in 0.1 s increments
Alarm logic
1oo1, 1oo2, 2oo2, 1oo3, 2oo3, 3oo3, 1oo4, 2oo4, 3oo4, 4oo4, 1oo2 AND 1oo2. 2oo2 OR 2oo2,1oo2 AND 2oo2, 2oo2 AND 1oo2
I/O logix control
Alarm actuates when logic control is set, Control on either of two controller output (I/O) bit, Control on either of two digital inputs (hardware)
I/O gating control
Alarm is evaluated when gate condition is true, Control on either of two controller output (I/O) bit, Control on either of two digital inputs (hardware)
Overall
Time constant
Tracking filters
Roll Off: -48 dB/octave
Real time
500 ms (typical)
SMAX
Per channel pair
Shaft absolute
Per channel pair
Not 1x
Number per channel: 1
Bias/gap
Number per channel: 1
gSE overall
Number per channel: 1
Isolation
Non-isolated, single-ended analog inputs. sensor signal returns must be isolated from ground
Number of digital inputs
2
Wiring category
2 - on signal ports, 2 - on power ports, 2 - on communications ports, 1 - on relay ports
Terminal pins
Surge protection: No
BNC
Surge protection: No
Number of buffered outputs
4
Notes
All outputs are single ended and have no isolation, Buffered output is not representative of input when no load (sensor) is connected to the associated measurement channel, Confirm that the connected instrumentation does not provide power, such as if to
Faults
Main module fault, Main module tachom fault, Expansion module fault, Ethernet network fault, Expansion bus fault
Voted alarm
Assign to any enabled voted alarm (0...12)
Relay action
Select fault on any of Module, Select fault on any of Expansion module, Select fault on any of Ethernet, Select fault on any of Expansion bus
Expansion bus link time-out
100 ms (fixed)
Indication
Update status indicator
Controller I/O
Status bit on controller input table
Application
Trip inhibit/bypass, Alarm/relay reset, Alarm SPM/gate control 0, 1, Tachom 0, 1 status
Number of digital outputs
2
Buffers
Four buffers each containing: 640 discrete records, 64 dynamic records
Overflow
When enabled allows buffers of up to 2560 discrete and 256 dynamic records
Sample Intervals
At delta RPM (off or 1...1000 RPM), At delta time (off or ≥ 1 s), Post start-up time, Dynamic records are captured every tenth trigger
Definition
Speed Source: 0.1, Transient minimum, Transient maximum speed, Startup: speed increases from under to over the maximum speed, Coastdown: speed decreases from over to under the maximum speed
Multiplexed
Configuration dependent
Two channel dynamic (40 kHz)
Channels 0 and 1 (pair) can be configured for Dynamic (AC) measurements with a measurement span of 40 kHz (1), or as gSE. Channels 2 and 3 are disabled (off).
Four channel dynamic (4 kHz)
Dual path: Measurement is the same as “four channel dynamic (4 kHz) or static, Inputs are internally connected between channels 0 and 2 and between channels 1 and 3
Two channel dynamic (20 kHz)
2 channel static: channels 0 and 1 can be configured for Dynamic (AC) measurements with an FMAX of up to 20.6 kHz (1236 kCPM), Channels 2 and 3 available for Static (DC) measurements.
Four channel dynamic (4 kHz) or static
All channels are available. Each channel pair can be defined for either Static (DC) or Dynamic (AC) measurements, Dynamic channels can be configured for an FMAX up to 4578 Hz (274.7 kCPM)
Status indicator
Power, Module status, Network status, Processor status, Processor operating state, DSP status, DSP operating state, Channel status (4), Relay status, Ethernet link status (2), Ethernet activity indicator (2)
Number of status indicators
16
Power
Passes power from each main module (1444-DYN04-01RA) to its expansion modules, Power is not passed between main modules, When redundant power supplies are connected to a main module, only the voted power source is distributed to its expansion modules.
Communication
A digital network that is used between a main module and its expansion modules is implemented on the local bus. Communication does not link main modules
TTL signals
Dual independent TTL signals, with tachom sensor status, are passed on the Local Bus, There can be only one tachom expansion module on a local bus, The TTL signal can serve up to six main modules
Number of tachometer inputs
2
Protection
Reverse polarity
Detection threshold
Fixed (-2.5V DC)
Transducer status
Only local bus inputs
Terminal inputs
TTL class with internal pull-up resistor (5V DC)
Local bus inputs
Opto-isolated TTL input for signal and TX status
Time stamp resolution
0.1 ms
Event types
System, Alarm, Buffer
Number of entries
1500 total records, 256 records per event type
Conditions
35 logged conditions, Categorized by event type
Asynchronous mode FMAX
30 Hz
Synchronous mode
Tachom source: 0, 1, SAles per rev: 8...128, Orders: 2.0...31.3
Trend alarm
Transducer
Aux processor
DSP processor
Alarm status
Channel setup
Relay status
Expansion module
Bandwidth FMAX
0.035 khz
High pass filter
-3 dB corner: 0.1 Hz to 1 kHz, -24, -60 dB/octave
Data speed
Alarm limits (16)
Set point multiplier enable
Alarm buffer reset
Alarm reset
Alarm gate control
Trip inhibit
Alarm buffer trigger
ADC out
Signal out of the ADC
Alternate path
Alternate signal path
Post filter
After high pass filter and integration
Mid filter
Before high pass filter and integration
Concurrent access
Controller (owner), Up to 3 (more) sessions
Supported connectivity protocols
Single Ethernet (IEEE 802.3), Device Level Ring (ODVA)
Communication protocol
ODVA-compliant (conformance tested) EtherNet/IP industrial protocol
IP address
Set by hardware switch on the terminal base as 192.168.0.xxx (last octet set by switch), Set in configuration using DHCP/BOOTP tools
Absolute shaft
Per channel pair, Ch-0/2: displacement, Ch-1/3: acceleration or velocity, Relative mounting: 0°, 180°
gSE
2 gSE channels max, Only 2-channel protection or surveillance modes, Overall, only TWF/FFT, HPF: 200, 500 Hz, 1, 2, 5 kHz, FFT FMAX: 100 Hz...5 kHz
Conformal coating
All printed circuit boards are conformal coated in accordance with IPC-A-610C and in compliance with: IPC-CC-830 B, UL508
Drawings
3D Dimension Drawings(STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3D Dimension Drawings(STP) Download (ZIP)
Product Drawing Drawing (DXF)
Type Resource Publication
General Product Cutsheet --
Technical Data 1444-td001_-en-p 1444-TD001
User Manual 1444-um001_-en-p 1444-UM001
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Search the Literature Library
Available Downloads
  • Firmware for 1444-DYN04-01RA v4.011
  • Condition Monitoring Device Library v1.01.00
See All Downloads
China CCC IECEx Scheme ATEX
  • China CCC
  • IECEx Scheme
  • ATEX
  • MOROCCO DOC
  • UK EX CERTIFICATE

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Items Per Page:
1-1 of 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
Buffer Outputs
4
Control Output
1 SPDT, +opt RELX (4 SPDT) x3
Interface
EtherNet/IP
Number Of Channels
4
Speed Inputs
2
Transducer Power
IEPE Accel, ECP's, Volts
Number of sensor inputs for IEPE sensors
4
Number of indicator outputs
16
Type of electric connection
Spring clA connection
Ethernet
True
Voltage type of supply voltage
DC
Supply voltage DC
18 V
Suitable for bus connection
True
Model
Basic device
Supply voltage
32V DC
Conductor type
Copper
Wire type
Shielded on signal connections, Only Shielded on Ethernet ports, Unshielded on power and relay ports
Number of rotational speed inputs
2
Type of fastening
DIN rail (top hat rail)
Depth
Without terminal base: 154 mm (6.06 in)
Height
Without terminal base: 106 mm (4.17 in)
Width
Without terminal base: 102 mm (4.02 in)
Modular expandable
True
Enclosure type rating
None (open-style)
Surrounding air temperature, max
70 °C
Operating temperature
-25 °C
Emissions
IEC 61000-6-4
Vibration
2.0 G @ 10…500 Hz
Shock
Operating: 15 G
EFT/B immunity
±2kV @ 5kHz on unshielded power ports, ±2kV @ 5kHz on shielded signal ports, ±2kV @ 5kHz on shielded Ethernet ports, ±3kV @ 5kHz on unshielded relay ports
Surge transient immunity
±1 kV line-line(DM) and ±2 kV line-earth(CM) on unshielded power and relay ports, ±2 kV line-earth(CM) on shielded signal ports, ±2 kV line-earth(CM) on shielded Ethernet ports
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Conductor/insulation temperature rating, min
85 °C
Operating temperature (spring type only), max
105 °C
Operating temperature (screw type only), max
115 °C
Nonoperating temperature
-40 °C
Relative humidity
5...95% noncondensing
ESD immunity
6 kV contact discharges, 8 kV air discharges
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
North American temperature code
T4
With approval according to UL
True
IEC temperature code
T4
Rated current, max
8 A AC
Rated voltage, max
250V AC
Inductive load
5A @ 250V AC
Switching capacity, max
90 W DC @ inductive load
Resistive load
8A @ 250V AC
Rated carry current
8 A
Number of relays
1
Electrical life cycles, min
50000
Mechanical life operations, min
10000000
Permissible load, min
10mA @ 5V DC
Releasing time, max
5 ms @ rated voltage
Operating time, max
15 ms @ rated voltage
Contact material
Gold plated @ surface material
Contact arrangement
Single pole double throw (SPDT) change-over contact
Measurement type
Rod drop
DC measurement types
Proportional voltage
Trigger source
Speed reference: 0 or 1
Sample rate
93 kS/s, 2 channels
Conversion
24 bit
Dynamic range
80 dBfs (0.01% fs), 90 dBfs typical
High-resolution samples
SAled rate: 100 ms
Saved trend buffer
640 static records: includes N% records sAled post trigger
Alarm form
Over/under threshold
Delay times
Separate delay times for alert and danger alarms
Processing mode
Profile: limits that are read from controller I/O
Set point multiplier range: 0.1...100x
Multiply the threshold limits by this value when invoked. Can be static: enabled by controller I/O or manual switch
Deadband
0 %
Sustain time
1.0 s (fixed)
Input parameter
Any real-time or discrete continuous measurement
Transducer state consideration
OK required, Not OK forces alarm, OK status is not considered
Speed acceleration
Update rate: 1 / s
Mode
Redundant: Speed 0 = Speed 1 when tach 0 in fault
Speed
Terminal pin: TTL
Speed, max
1 per speed measurement, Maximum speed since reset, Reset via controller I/O,
Static data
SAle rate: N x 100 Ms
Dynamic data
SAle rate(1): N x 100 ms
Transducer positive power
Voltage regulated: 24V/25 mA
Number of channel inputs
4
Impedance
>100 kΩ
Transducer negative power
Voltage regulated: -24V/25 mA
Sensor types
CP accelerom (CCS), Dynamic pressure transducers, Dual sensors (acceleration + temperature), Eddy current probe systems (-24V DC), Self-powered sensors, Voltage signals
Transducer fault detection
Bias level high / low limits, Current threshold level monitoring, which is implemented in hardware for -24V supplied sensors. provides the fastest fault detection possible with excellent reliability.
Frequency, max
Surveillance: 40 kHz (OA only)
Resolution
3 µV (theoretical)
Sampling mode
Synchronous
Integration
None, single or double
Low pass filter
-3 dB corner 10 Hz to 40 kHz, -24, -60 dB/octave
Signal detection
Peak to peak, Peak, RMS, Calculated peak to peak, Calculated peak
Voltage ranges
±24V DC
Time waveform
SAle rate: ≤Fmax
Data source
Selectable: post filter, mid filter, alternate path
FFT
Windows: none, flat top, hamming, hanning
Record content
Dynamic data: TWF and FFT per channel
Enable
Enable static data capture, Enable dynamic data capture
FFT bands
Order domain speed ref: 0, 1
Type
TTL class
gSE FFT
Number per channel: 1
Data format
32-bit float
Voltage
North American: 18...32V, max 8 A, limited voltage source
Isolation voltage
50V (continuous), basic insulation type between Ethernet, power, ground, and AUX bus, 50V (continuous), basic insulation type between signal ports, power, ground, and AUX bus, 250V (continuous), basic insulation type between relay ports and system, No
Dissipation
9 W
Number of connections
2
Consumption
11.5 W
Connections
Terminal pin
Current
411mA @ 24V (546...319mA @ 18...32V)
Redundant power
Two 18...32V DC, max 8 A SELV power supply inputs, Higher voltage supply is applied to main and expansion modules
Power monitor
The two power supply voltage levels are monitored. status indicated via process operating status indicators and on controller input (I/O)
Weight
Without terminal base: 0.40 kg (0.88 lb)
Stripping length
9 mm
Conductor UL/cUL AWG (spring type only), max
1.5 mm²
Conductor cross section solid or stranded
0.14
Conductor crosssection stranded with ferrule without plastic sleeve
0.25
Conductor crosssection stranded with ferrule with plastic sleeve
0.25
Conductor cross section AWG/kcmil
0.08
Conductor UL/cUL AWG (screw type only)
0.05 mm²
Conductor UL/cUL AWG (spring type only)
0.08 mm²
Torque (screw type only)
0.22 nm
Accuracy
Maximum drift: 100 ms per year
Synchronization
Clock synchronized to controller time per IEEE-1588 V2 / CIP sync (ODVA) standard
Failsafe
If assigned to a relay, when in alarm the relay coil is deenergized
Latching
Non-latching, resets when condition clears, Latching, after condition clears, resets upon command via controller I/O
Number
Voted alarms: 13
Logic inputs
1...4 measurement alarms
Input condition
Alert, Danger, Transducer fault
SPM control source
Controller I/O SPM control bit 0 or 1/digital input 0 or 1
Speed gating control
Speed reference: 0, 1, Condition (>, <, <>, ><), Speed limits (low, high)
SPM timer
Number of s the SPM is applied after SPM signal is reset, From 0...65.5 s in 0.1 s increments
Alarm logic
1oo1, 1oo2, 2oo2, 1oo3, 2oo3, 3oo3, 1oo4, 2oo4, 3oo4, 4oo4, 1oo2 AND 1oo2. 2oo2 OR 2oo2,1oo2 AND 2oo2, 2oo2 AND 1oo2
I/O logix control
Alarm actuates when logic control is set, Control on either of two controller output (I/O) bit, Control on either of two digital inputs (hardware)
I/O gating control
Alarm is evaluated when gate condition is true, Control on either of two controller output (I/O) bit, Control on either of two digital inputs (hardware)
Overall
Time constant
Tracking filters
Roll Off: -48 dB/octave
Real time
500 ms (typical)
SMAX
Per channel pair
Shaft absolute
Per channel pair
Not 1x
Number per channel: 1
Bias/gap
Number per channel: 1
gSE overall
Number per channel: 1
Isolation
Non-isolated, single-ended analog inputs. sensor signal returns must be isolated from ground
Number of digital inputs
2
Wiring category
2 - on signal ports, 2 - on power ports, 2 - on communications ports, 1 - on relay ports
Terminal pins
Surge protection: No
BNC
Surge protection: No
Number of buffered outputs
4
Notes
All outputs are single ended and have no isolation, Buffered output is not representative of input when no load (sensor) is connected to the associated measurement channel, Confirm that the connected instrumentation does not provide power, such as if to
Faults
Main module fault, Main module tachom fault, Expansion module fault, Ethernet network fault, Expansion bus fault
Voted alarm
Assign to any enabled voted alarm (0...12)
Relay action
Select fault on any of Module, Select fault on any of Expansion module, Select fault on any of Ethernet, Select fault on any of Expansion bus
Expansion bus link time-out
100 ms (fixed)
Indication
Update status indicator
Controller I/O
Status bit on controller input table
Application
Trip inhibit/bypass, Alarm/relay reset, Alarm SPM/gate control 0, 1, Tachom 0, 1 status
Number of digital outputs
2
Buffers
Four buffers each containing: 640 discrete records, 64 dynamic records
Overflow
When enabled allows buffers of up to 2560 discrete and 256 dynamic records
Sample Intervals
At delta RPM (off or 1...1000 RPM), At delta time (off or ≥ 1 s), Post start-up time, Dynamic records are captured every tenth trigger
Definition
Speed Source: 0.1, Transient minimum, Transient maximum speed, Startup: speed increases from under to over the maximum speed, Coastdown: speed decreases from over to under the maximum speed
Multiplexed
Configuration dependent
Two channel dynamic (40 kHz)
Channels 0 and 1 (pair) can be configured for Dynamic (AC) measurements with a measurement span of 40 kHz (1), or as gSE. Channels 2 and 3 are disabled (off).
Four channel dynamic (4 kHz)
Dual path: Measurement is the same as “four channel dynamic (4 kHz) or static, Inputs are internally connected between channels 0 and 2 and between channels 1 and 3
Two channel dynamic (20 kHz)
2 channel static: channels 0 and 1 can be configured for Dynamic (AC) measurements with an FMAX of up to 20.6 kHz (1236 kCPM), Channels 2 and 3 available for Static (DC) measurements.
Four channel dynamic (4 kHz) or static
All channels are available. Each channel pair can be defined for either Static (DC) or Dynamic (AC) measurements, Dynamic channels can be configured for an FMAX up to 4578 Hz (274.7 kCPM)
Status indicator
Power, Module status, Network status, Processor status, Processor operating state, DSP status, DSP operating state, Channel status (4), Relay status, Ethernet link status (2), Ethernet activity indicator (2)
Number of status indicators
16
Power
Passes power from each main module (1444-DYN04-01RA) to its expansion modules, Power is not passed between main modules, When redundant power supplies are connected to a main module, only the voted power source is distributed to its expansion modules.
Communication
A digital network that is used between a main module and its expansion modules is implemented on the local bus. Communication does not link main modules
TTL signals
Dual independent TTL signals, with tachom sensor status, are passed on the Local Bus, There can be only one tachom expansion module on a local bus, The TTL signal can serve up to six main modules
Number of tachometer inputs
2
Protection
Reverse polarity
Detection threshold
Fixed (-2.5V DC)
Transducer status
Only local bus inputs
Terminal inputs
TTL class with internal pull-up resistor (5V DC)
Local bus inputs
Opto-isolated TTL input for signal and TX status
Time stamp resolution
0.1 ms
Event types
System, Alarm, Buffer
Number of entries
1500 total records, 256 records per event type
Conditions
35 logged conditions, Categorized by event type
Asynchronous mode FMAX
30 Hz
Synchronous mode
Tachom source: 0, 1, SAles per rev: 8...128, Orders: 2.0...31.3
Trend alarm
Transducer
Aux processor
DSP processor
Alarm status
Channel setup
Relay status
Expansion module
Bandwidth FMAX
0.035 khz
High pass filter
-3 dB corner: 0.1 Hz to 1 kHz, -24, -60 dB/octave
Data speed
Alarm limits (16)
Set point multiplier enable
Alarm buffer reset
Alarm reset
Alarm gate control
Trip inhibit
Alarm buffer trigger
ADC out
Signal out of the ADC
Alternate path
Alternate signal path
Post filter
After high pass filter and integration
Mid filter
Before high pass filter and integration
Concurrent access
Controller (owner), Up to 3 (more) sessions
Supported connectivity protocols
Single Ethernet (IEEE 802.3), Device Level Ring (ODVA)
Communication protocol
ODVA-compliant (conformance tested) EtherNet/IP industrial protocol
IP address
Set by hardware switch on the terminal base as 192.168.0.xxx (last octet set by switch), Set in configuration using DHCP/BOOTP tools
Absolute shaft
Per channel pair, Ch-0/2: displacement, Ch-1/3: acceleration or velocity, Relative mounting: 0°, 180°
gSE
2 gSE channels max, Only 2-channel protection or surveillance modes, Overall, only TWF/FFT, HPF: 200, 500 Hz, 1, 2, 5 kHz, FFT FMAX: 100 Hz...5 kHz
Conformal coating
All printed circuit boards are conformal coated in accordance with IPC-A-610C and in compliance with: IPC-CC-830 B, UL508
Drawings
Drawings
3D Dimension Drawings(STP) Download (ZIP)
Product Drawing Drawing (DXF)
Drawings
3D Dimension Drawings(STP) Download (ZIP)
Product Drawing Drawing (DXF)
Documents
Product Cutsheet General
--
1444-td001_-en-p Technical Data
1444-TD001
1444-um001_-en-p User Manual
1444-UM001
Type Resource Publication
General Product Cutsheet --
Technical Data 1444-td001_-en-p 1444-TD001
User Manual 1444-um001_-en-p 1444-UM001
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Search the Literature Library
Downloads
Available Downloads
  • Firmware for 1444-DYN04-01RA v4.011
  • Condition Monitoring Device Library v1.01.00
See All Downloads
Certifications
China CCC IECEx Scheme ATEX
  • China CCC
  • IECEx Scheme
  • ATEX
  • MOROCCO DOC
  • UK EX CERTIFICATE

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Alternative Products
Items Per Page:
1-1 of 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading
Find your nearest distributor
Contact your distributor in {0}
Change location
EmailEmail
PhonePhone
Find a partner
Dynamic Measurement Module
CloseClose
1444-DYN04-01RA
Close
Print
Chevron LeftChevron Left
Allen-Bradley 1444-DYN04-01RA product image
Chevron LeftChevron Left
Allen-Bradley 1444-DYN04-01RA product image
Allen-Bradley 1444-DYN04-01RA product image
Phone:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
Sign in to your Rockwell Automation account to submit a repair documentation request.
Sign In
Request repair documentation
All fields with * are required for processing your request.
This field is required
This field is required
This field is required
This field is required
This field is required
Documentation of liability insurance is required for anyone who is requesting documentation for product repairs.
UploadUpload
Please upload documentation of liability insurance.*
1 file selected
CloseClose
File size is too large. Must be less than 5 MB.
Accepted file types: zip, pdf; Maximum size: 5 MB.
Right to Repair Terms and Conditions
Rockwell Automation is making, parts, and service documentation available at your request in compliance with applicable right to repair laws and regulations. By signing below, you are agreeing to the following terms and conditions of your purchase of Rockwell Automation genuine repair parts for repair of a Rockwell Automation product. As used below, “Self Service Repair Parts” means genuine Rockwell Automation parts (components of Rockwell Automation products) purchased from Rockwell Automation for installation in a Rockwell Automation product as part of a Self Service Repair. Self Service Repair Parts may be new or previously used genuine Rockwell Automation parts that have been tested and passed Rockwell Automation functional requirements. “Self Service Repair Tools” means equipment and related materials purchased for the purpose of performing repairs.
Your request has been successfully submitted.
Please allow up to 5 business days to receive a response to your inquiry.
  1. Chevron LeftChevron Left Rockwell Automation Home
  2. Chevron LeftChevron Left Products
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose