Frame 7 Kits

This table lists the renewal kits available for
PowerFlex®
755T frame 7 products. (XT) appears in the table title to help identify a kit that contains protective covers and/or dielectric grease on connectors.
Frame 7 Ventilation Renewal Kits
Cat. No.
Description
Notes
SK-RM-PBFAN-54FLTR1
IP54 Exhaust Vent Filters
Each kit contains two filters. Frame 7 enclosures require two kits (four filters).
SK-RM-PB8DR-54FLTR1
IP54, 800 mm wide Door Vent Filters
—
SK-RM-PB8DR-21FLTR1
IP21, 800 mm wide Door Vent Filters
—
Frame 7 Control Pod (XT) Renewal Kits
Cat. No.
Description
Notes
SK-RM-CR1
Control Pod HIM Cradle with
DPI™
Connector
—
SK-RM-PODFAN-F7
Control Pod Printed Circuit Board Fan Assembly
—
SK-RM-MCB2-PF755
Main Control Circuit Board
This catalog number supports
PowerFlex®
755T firmware revisions 10.001 and later only. Use this renewal kit with
PowerFlex®
755T products with an “E” in catalog number position 4.
SK-RM-PODBP1
Control Pod Backplane Circuit Board
—
20-750-MFTB1-F8
Fiber Transceiver Circuit Board
—
20-750-MCPOD3-F7M
Control Pod Assembly, Regenerative Drive and Bus Supply
This catalog number supports
PowerFlex®
755T firmware revisions 10.001 and later only. Use this renewal kit with
PowerFlex®
755T products with an “E” in catalog number position 4.
20-750-MCPOD4-F7M
Control Pod Assembly, Low Harmonic Drive
This catalog number supports
PowerFlex®
755T firmware revisions 10.001 and later only. Use this renewal kit with
PowerFlex®
755T products with an “E” in catalog number position 4.
Frame 7 Control Pod (Standard) Renewal Kits
Cat. No.
Description
Notes
SK-RM-MCB1-PF755
Main Control Circuit Board
This kit catalog number supports
PowerFlex®
755T firmware revisions 6.xxx and earlier only. Use this renewal kit with
PowerFlex®
755T products with a “1” in catalog number position 4.
20-750-MCPOD1-F7M
Control Pod Assembly, Regenerative Drive and Bus Supply
This kit catalog number supports
PowerFlex®
755T firmware revisions 6.xxx and earlier only. Use this renewal kit with
PowerFlex®
755T products with a “1” in catalog number position 4.
20-750-MCPOD2-F7M
Control Pod Assembly, Low Harmonic Drive
This kit catalog number supports
PowerFlex®
755T firmware revisions 6.xxx and earlier only. Use this renewal kit with
PowerFlex®
755T products with a “1” in catalog number position 4.
Frame 7 Cooling Fan Renewal Kit
Cat. No.
Description
Notes
SK-RM-MFAN-F7
LCL Filter and Power Module Heatsink Fan Assembly
—
Frame 7 Control Power Renewal Kits
Cat. No.
Description
Notes
SK-RM-IBFH2-FUSE2A-F8
400V/480V/600V, 240V Power Distribution Fuse (FH2)
15 A Fuse Rating
SK-RM-IBFH2-FUSE2B-F8
690V, 240V Power Distribution Fuse (FH2)
16 A Fuse Rating
Frame 7 AC Precharge Renewal Kits
Cat. No.
Description
Notes
SK-RM-EMCFB1
AC Common Mode Filter Circuit Board
—
20-750-MACPC1-CD-F7M
400V/480V, AC Precharge Control Circuit Board (XT)
—
20-750-MACPC1-EF-F7M
600V/690V, AC Precharge Control Circuit Board (XT)
—
SK-RM-IBFH2-FUSE2A-F8
400V/480V/600V Control Transformer Fuses (FH4)
One 15 A Fuse
SK-RM-IBFH4-FUSE5A-F7
400V/480V/600V Control Transformer Fuses (FH4)
Two 17.5 A Fuses
SK-RM-IBFH2-FUSE2B-F8
690V, Control Transformer Fuses (FH4)
One 16 A Fuse
SK-RM-IBFH4-FUSE5B-F7
690V, Control Transformer Fuses (FH4)
Two 10 A Fuses
SK-RM-IBFH3-FUSE3B-F8
400V/480V/600V, AC Precharge Control Circuit Board Fuse (FH3)
2 A Fuse Rating
SK-RM-IBFH3-FUSE3A-F8
690V, AC Precharge Control Circuit Board Fuse (FH3)
2 A Fuse Rating
SK-RM-IBD-FUSEA-F8
400V/480V/600V, AC Precharge Fused Disconnect (FD1) Fuses
30 A Fuse Rating
SK-RM-IBD-FUSEB-F8
690V, AC Precharge Fused Disconnect (FD1) Fuses
32 A Fuse Rating
20-750-MACPC-TDR
AC Precharge Time Delay Relay
—
20-750-MACP-CD-TVSS
AC Precharge TVSS Module, 400V/480V
—
20-750-MACP-EF-TVSS
AC Precharge TVSS Module, 600V/690V
—
Frame 7 Power Module Renewal Kits
Cat. No.
Description
Notes
20-750-MI4-CnnnDnnn, 20-750-MI4-EnnnFnnn
Frame 7 Power Module (XT)
"nnn" in “CnnnDnnn” and “EnnnFnnn” identifies the normal duty (ND) continuous amp rating of the power module. To identify your catalog number, see the data nameplate on the front of the power module.
SK-RM-DCFUSE1-F8
400V/480V Power Module DC Link Fuses
—
SK-RM-DCFUSE2-F8
600V/690V Power Module DC Link Fuses
—
SK-RM-PLI1-F8
Power Module Power Layer Interface Circuit Board (XT)
—
SK-RM-PIB4-CnnnDnnn, SK-RM-PIB4-EnnnFnnn
Power Module Power Interface Circuit Board
“C” and “D” in “CnnnDnnn” identifies a circuit board compatible with a power module that is rated for 400/480V, respectively. “E” and “F” in “EnnnFnnn” identifies a circuit board compatible with a power module that is rated for 600/690V, respectively. “nnn” in “CnnnDnnn” and “EnnnFnnn” identifies the normal duty (ND) continuous amp rating the power module that the circuit board is compatible with.
Frame 7 LCL Filter Module Renewal Kits
Cat. No.
Description
Notes
20-750-ML4-CnnnDnnn, 20-750-ML4-EnnnFnnn
LCL Filter Module (XT)
"nnn" in “CnnnDnnn” and “EnnnFnnn” identifies the normal duty (ND) continuous amp rating of the LCL filter module. To identify your catalog number, see the data nameplate on the front of the LCL filter module.
SK-RM-ACFUSE1-F8
400V/480V LCL Filter Module AC Input Fuses
—
SK-RM-ACFUSE5-F8
600V/690V LCL Filter Module AC Input Fuses
—
SK-RM-CSB-F7
LCL Filter Module Current Sense Circuit Board (XT)
—