Save As dialog box

Use this dialog box to save the project file. To open the
Save As
dialog box, select
File
>
Save as
TIP:
Saving the project as a new file does not change the name of the controller. To change the controller name, use the
General
tab of the
Controller Properties
dialog box.
This table describes the settings on the dialog box.
Setting
Description
Save in
Specify the directory in which to save this project or in which to export the project.
File name
Enter the name for the saved or exported file.
Save as type
Choose the type of file to save or the file to export:
  • Studio 5000 Logix Designer
    Project File (*.ACD)
    .ACD
    The file extension used for project files created by the
    Studio 5000 Logix Designer
    application.
  • Studio 5000 Logix Designer
    Import-Export File (*.L5K)
    .L5K
    A file format used for text files imported and exported by the
    Studio 5000 Logix Designer
    application. An .L5K file contains an ASCII representation of the data for an entire project and, when imported, creates a new project file or overwrites an existing project file.
    The file extension for this format must be .L5K; if you change the extension using a tool like the Windows Explorer, the
    Studio 5000 Logix Designer
    application is not able to import this file.
  • Studio 5000 Logix Designer
    Import-Export File (*.L5X)
    .L5X
    The .L5X file is structured using Extensible Markup Language (XML) tags. In addition to being able to open and modify the .L5X file in a text editor, such as Notepad, you can also view the contents of the file in Microsoft Internet Explorer and other tools that work with XML files.
    You can import and export a project by exporting ladder rungs (including the referenced tags and data types), trends, User-defined Data Types, Add-On Instructions, programs, equipment phases, and routines to an .L5X file and importing it into the required project.
  • AutomationML File (*.AML)
    .AML
    AutomationML (AML) uses an .aml file to exchange data.
    AML is an open industry standard format dedicated to automation usage. The AML specification includes a set of data structures implemented in the application. This implementation enables interoperability with other software applications that use the AutomationML Automation Project Configuration format, such as EPLAN Electric.
    Some Rockwell Automation devices are only partially supported by the AML format because they include capabilities that are not within the scope of the current AML standard. When a product is partially supported, it can be imported or exported but may require some additional configuration to reconfigure the unsupported features. Check the Errors window in the Logix Designer application for details.
  • Resource Description Framework File (*.RDF)
    .RDF
    Web Ontology Language (OWL) uses an .rdf file to exchange data.
    Recommended for the most rich data exchange with all Rockwell Automation specific features identified for data exchange. The RDF (Resource Description Framework) serves for data representation, OWL (Web Ontology Language) builds on RDF and defines the dictionary. Both are open standards for data exchange. They are used as a basis for a Rockwell Automation specific data format.
    TIP: When exchanging data between Rockwell Automation software applications, always use the RDF file type.
  • Studio 5000 Logix Designer
    Package File (*.LPF)
    .LPF
    The .LPF file is a packaged project file containing encoded controller configuration and logic. The LPF project file can be deployed to controller independently from Logix Designer.
    Studio 5000 Logix Designer
    digitally signs a .LPF file during the
    Save as
    operation using a certificate tied to the engineering workstation's Trusted Platform Module (TPM).
    To save as a .LPF file, make sure that the following prerequisites are met:
    • An LPF certificate is installed.
      For more information, see Install an LPF certificate.
    • You have the download permission in
      FactoryTalk Administration Console
      .
      In
      FactoryTalk Administration Console
      Explorer
      , expand the network or local directory tree for
      Permission Sets
      . Right-click related set and select
      Security
      . On the
      Permissions
      tab, allow
      Project: Download
      . This configuration requires
      FactoryTalk Directory
      administrative permission. If you do not have administrative permission, contact a
      FactoryTalk Directory
      administrator to configure it for you.
    • The selected target is a
      LogixEdge
      controller.
    • You have access to TPM 2.0 module.
Encode Protected Content
Exports protected content in encoded format. Routines and Add-On Instructions can be exported in an encoded format when protected with
FactoryTalk Security
and/or Source Protection.
Enabled when choosing either .L5K or .L5X from the
Save as type
menu, and
Always Encode Protected Content on Export
in the
Workstation Options
dialog box is cleared.
Select to export protected content in an encrypted format, even when source key or other credentials for the content are present. Clear to export protected content in clear text.
TIP:
When exporting a project, only controls the encoded export of protected components, such as routines or Add-On Instructions, that can be exported encoded.
TIP:
Protection permissions (such as permissions configured in
FactoryTalk Security
or Source Protection) can override this selection. When checkbox cleared, the component is still exported encoded even if no permission to export unencoded.