Reference (REF)
The Reference (REF) Instruction associates a reference with the address of an axis or coordinate system concrete tag.
This is a transitional instruction. Follow these steps when using it:
- In ladder logic, insert an instruction to toggle the rung-condition-in from false to true each time the instruction should execute.
- In a Structured Text routine, insert a condition for the instruction to cause it to execute only on a transition.
Available Instructions
Ladder Diagram

Function Block
This instruction is not available in function block.
Structured Text
REF(Source, Reference);
Operands
Operand | Type | Format | Description |
|---|---|---|---|
Source | AXIS_CIP_DRIVE AXIS_CONSUMED AXIS_GENERIC_DRIVE AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL COORDINATE_SYSTEM | Immediate Tag | Name of the axis or coordinate system to reference. |
Reference | REF_TO_AXIS_CIP_DRIVE REF_TO_AXIS_CONSUMED REF_TO_AXIS_GENERIC_DRIVE REF_TO_AXIS_SERVO REF_TO_AXIS_SERVO_DRIVE REF_TO_AXIS_VIRTUAL REF_TO_COORDINATE_SYSTEM | Tag | Name of the reference to be populated. |
Affects Math Status Flags
No
Major/Minor Faults
None specific to this instruction.
Execution
Condition/State | Action Taken |
|---|---|
Prescan | The instruction uses the Source address to populate the Reference. |
Rung-condition-in is false | Set Rung-condition-out to Rung-condition-in. The instruction uses the Source
address to populate the Reference. |
Rung-condition-in is true | Set Rung-condition-out to Rung-condition-in. The instruction uses the Source address to populate the Reference. |
Postscan | The instruction uses the Source address to populate the Reference. |
Error Codes
None specific to this instruction.
Example
Relay Ladder

Structured Text
REF(AxisCip, Ref_AxisCip);
Provide Feedback