Module-defined Data Types (1756-DMD30)
    Module-defined data type names vary for each module depending on the Communication Format you choose when you create a module. The tables below list and describe the module-defined data types created for the 1756-DMD30 module, according to the Communication Format chosen. This includes information for Input (as indicated by an "I") and Output (as indicated by an "O").
Module-defined Data Type: AB: DMD30_VELOCITYCONTROL:I:0
Comm Format: Velocity Control
| Member Name | Bit in Previous Word | Data Type | Default Display Style | Drive Parameter | Description | 
| LogicStatus | DINT | Binary | 155 | Logic Status | |
| Enabled | 0* | BOOL | Decimal | 155.0 | Enabled | 
| Running | 1* | BOOL | Decimal | 155.1 | Running | 
| CommandDir | 2* | BOOL | Decimal | 155.2 | Command Dir | 
| ActualDir | 3* | BOOL | Decimal | 155.3 | Actual Dir | 
| Accelerating | 4 | BOOL | Decimal | 155.4 | Accelerating | 
| Decelerating | 5 | BOOL | Decimal | 155.5 | Decelerating | 
| Jogging | 6 | BOOL | Decimal | 155.6 | Jogging | 
| Faulted | 7* | BOOL | Decimal | 155.7 | Faulted | 
| Alarm | 8* | BOOL | Decimal | 155.8 | Alarm | 
| FlashMode | 9* | BOOL | Decimal | 155.9 | Flash Mode | 
| RunReady | 10 | BOOL | Decimal | 155.10 | Run Ready | 
| AtLimit | 11 | BOOL | Decimal | 155.11 | At Limit | 
| TachLossSw | 12 | BOOL | Decimal | 155.12 | Tach Loss Sw | 
| AtZeroSpd | 13 | BOOL | Decimal | 155.13 | At Zero Spd | 
| AtSetptSpd | 14 | BOOL | Decimal | 155.14 | At Setpt Spd | 
| AtSetpt1 | 16 | BOOL | Decimal | 155.16 | At Setpt 1 | 
| AboveSetpt2 | 17 | BOOL | Decimal | 155.17 | Above Setpt2 | 
| MCEnAck | 18 | BOOL | Decimal | 155.18 | MC En Ack | 
| MCCommis | 19 | BOOL | Decimal | 155.19 | MC Commis | 
| SpdCommis | 20 | BOOL | Decimal | 155.20 | Spd Commis | 
| TorqueMode | 22 | BOOL | Decimal | 155.22 | Torque Mode | 
| SpeedMode | 23 | BOOL | Decimal | 155.23 | Speed Mode | 
| PositionMode | 24 | BOOL | Decimal | 155.24 | PositionMode | 
| StartLatch | 25 | BOOL | Decimal | 155.25 | Start Latch | 
| CommandRun | 26 | BOOL | Decimal | 155.26 | Command Run | 
| FieldCurrOn | 30 | BOOL | Decimal | 155.30 | FieldCurr On | 
| FilteredSpdFdbk | REAL | Float | 71 | Filtered SpdFdbk | |
| MotorTorqueRef | REAL | Float | 303 | Motor Torque Ref | |
| OutputCurrent | REAL** | Float | 308 | Output Current | |
| MCFaults | DINT | Decimal | 2122 | MC Faults | |
| SCRFault | 0 | BOOL | Decimal | 2122.0 | SCR Fault | 
| MContLost | 1 | BOOL | Decimal | 2122.1 | M Cont Lost | 
| ACLineSync | 3 | BOOL | Decimal | 2122.3 | AC Line Sync | 
| InstOvrCurr | 4 | BOOL | Decimal | 2122.4 | InstOvr Curr | 
| ConductionTO | 5 | BOOL | Decimal | 2122.5 | ConductionTO | 
| FieldLoss | 6 | BOOL | Decimal | 2122.6 | Field Loss | 
| TachLoss | 7 | BOOL | Decimal | 2122.7 | Tach Loss | 
| TachWireOpn | 8 | BOOL | Decimal | 2122.8 | TachWire Opn | 
| ResolverCard | 9 | BOOL | Decimal | 2122.9 | ResolverCard | 
| OverSpeed | 10 | BOOL | Decimal | 2122.10 | Over Speed | 
| PwrTechCard | 11 | BOOL | Decimal | 2122.11 | PwrTech Card | 
| PMIPwrSply | 12 | BOOL | Decimal | 2122.12 | PMI Pwr Sply | 
| PMIBus | 13 | BOOL | Decimal | 2122.13 | PMI Bus | 
| PMICommLoss | 15 | BOOL | Decimal | 2122.15 | PMI CommLoss | 
| MCWarnings | DINT | Decimal | 2123 | MC Warnings | |
| BrdgNotFirng | 0 | BOOL | Decimal | 2123.0 | BrdgNotFirng | 
| LowACLine | 1 | BOOL | Decimal | 2123.1 | Low AC Line | 
| LineSyncLoss | 3 | BOOL | Decimal | 2123.3 | LineSyncLoss | 
| CurrRefLim | 4 | BOOL | Decimal | 2123.4 | Curr Ref Lim | 
| IDTestAbort | 5 | BOOL | Decimal | 2123.5 | ID TestAbort | 
| FieldOvrCurr | 6 | BOOL | Decimal | 2123.6 | FieldOvrCurr | 
| ArmFdbkRev | 7 | BOOL | Decimal | 2123.7 | Arm Fdbk Rev | 
| CTFdbkRev | 8 | BOOL | Decimal | 2123.8 | CT Fdbk Rev | 
| PMIFanLoss | 12 | BOOL | Decimal | 2123.12 | PMI Fan Loss | 
| RailIOComm | 13 | BOOL | Decimal | 2123.13 | Rail IO Comm | 
| PMICommSync | 14 | BOOL | Decimal | 2123.14 | PMI CommSync | 
| PMIComm | 15 | BOOL | Decimal | 2123.15 | PMI Comm | 
| UserDefinedRealData | REAL[7] | Float | User-defined | User-defined Real Data | |
| UserDefinedIntegerData | DINT[3] | Decimal | User-defined | User-defined Integer Data | 
* Location of these bits are fixed for DPI.
** Decimal number displayed as 10x actual value (e.g., 15 represents 1.5 amps).
Module-defined Data Type: AB: DMD30_VELOCITYCONTROL:O:0
Comm Format: Velocity Control
| Member Name | Bit in Previous Word | Data Type | Default Display Style | Drive Parameter | Description | 
| LogicCommand | DINT | Binary | 151 | Logic Command | |
| SpdRampDsbl | 0 | BOOL | Decimal | 151.0 | SpdRamp Dsbl | 
| SpdSCrvEn | 1 | BOOL | Decimal | 151.1 | Spd S Crv En | 
| TachLossRst | 2 | BOOL | Decimal | 151.2 | TachLoss Rst | 
| TimeAxisEn | 3 | BOOL | Decimal | 151.3 | Time Axis En | 
| MCAtuneEn | 4 | BOOL | Decimal | 151.4 | MC Atune En | 
| MtrInertEn | 8 | BOOL | Decimal | 151.8 | Mtr Inert En | 
| SysInertEn | 9 | BOOL | Decimal | 151.9 | Sys Inert En | 
| InertiaComp | 10 | BOOL | Decimal | 151.10 | Inertia Comp | 
| FrictComp | 11 | BOOL | Decimal | 151.11 | Frict Comp | 
| ProcsTrimEn | 12 | BOOL | Decimal | 151.12 | ProcsTrim En | 
| NormalStop | 16 | BOOL | Decimal | *Logic Parser | Normal Stop | 
| Start | 17 | BOOL | Decimal | *Logic Parser | Start | 
| Jog1 | 18 | BOOL | Decimal | *Logic Parser | Jog 1 | 
| ClearFault | 19 | BOOL | Decimal | *Logic Parser | Clear Fault | 
| UnipolFwd | 20 | BOOL | Decimal | *Logic Parser | Unipol Fwd | 
| UnipolRev | 21 | BOOL | Decimal | *Logic Parser | Unipol Rev | 
| Jog2 | 23 | BOOL | Decimal | *Logic Parser | Jog 2 | 
| CurrLimStop | 24 | BOOL | Decimal | *Logic Parser | CurrLim Stop | 
| CoastStop | 25 | BOOL | Decimal | *Logic Parser | Coast Stop | 
| PositionEn | 26 | BOOL | Decimal | *Logic Parser | Position En | 
| FieldEn | 30 | BOOL | Decimal | *Logic Parser | Field En | 
| SpeedRef1 | REAL | Float | 10 | Speed Ref 1 | |
| TorqueRef1 | REAL | Float | 111 | Torque Ref 1 | |
| SpdTorqModeSel | DINT | Decimal | 110 | Spd/Torq ModeSel | |
| TorqueStep | REAL | Float | 116 | Torque Step | |
| SpdRegDroop | REAL | Float | 86 | Spd Reg Droop | |
| UserDefinedRealData | REAL[7] | Float | User-defined | User-defined Real Data | |
| UserDefinedIntegerData | DINT[3] | Decimal | User-defined | User-defined Integer Data | 
* The output from the Logic Parser is mapped to parameter 152, bits 16-31.
Module-defined Data Type: AB: DMD30_POSITIONCONTROL:I:0
Comm Format: Position Control
| Member Name | Bit in Previous Word | Data Type | Default Display Style | Drive Parameter | Description | 
| LogicStatus | DINT | Binary | 155 | Logic Status | |
| Enabled | 0* | BOOL | Decimal | 155.0 | Enabled | 
| Running | 1* | BOOL | Decimal | 155.1 | Running | 
| CommandDir | 2* | BOOL | Decimal | 155.2 | Command Dir | 
| ActualDir | 3* | BOOL | Decimal | 155.3 | Actual Dir | 
| Accelerating | 4 | BOOL | Decimal | 155.4 | Accelerating | 
| Decelerating | 5 | BOOL | Decimal | 155.5 | Decelerating | 
| Jogging | 6 | BOOL | Decimal | 155.6 | Jogging | 
| Faulted | 7* | BOOL | Decimal | 155.7 | Faulted | 
| Alarm | 8* | BOOL | Decimal | 155.8 | Alarm | 
| FlashMode | 9* | BOOL | Decimal | 155.9 | Flash Mode | 
| RunReady | 10 | BOOL | Decimal | 155.10 | Run Ready | 
| AtLimit | 11 | BOOL | Decimal | 155.11 | At Limit | 
| TachLossSw | 12 | BOOL | Decimal | 155.12 | Tach Loss Sw | 
| AtZeroSpd | 13 | BOOL | Decimal | 155.13 | At Zero Spd | 
| AtSetptSpd | 14 | BOOL | Decimal | 155.14 | At Setpt Spd | 
| AtSetpt1 | 16 | BOOL | Decimal | 155.16 | At Setpt 1 | 
| AboveSetpt2 | 17 | BOOL | Decimal | 155.17 | Above Setpt2 | 
| MCEnAck | 18 | BOOL | Decimal | 155.18 | MC En Ack | 
| MCCommis | 19 | BOOL | Decimal | 155.19 | MC Commis | 
| SpdCommis | 20 | BOOL | Decimal | 155.20 | Spd Commis | 
| TorqueMode | 22 | BOOL | Decimal | 155.22 | Torque Mode | 
| SpeedMode | 23 | BOOL | Decimal | 155.23 | Speed Mode | 
| PositionMode | 24 | BOOL | Decimal | 155.24 | PositionMode | 
| StartActive | 25 | BOOL | Decimal | 155.25 | Start Active | 
| CommandRun | 26 | BOOL | Decimal | 155.26 | Command Run | 
| FieldCurrOn | 30 | BOOL | Decimal | 155.30 | FieldCurr On | 
| FilteredSpdFdbk | REAL | Float | 71 | Filtered SpdFdbk | |
| MotorTorqueRef | REAL | Float | 303 | Motor Torque Ref | |
| OutputCurrent | REAL** | Float | 308 | Output Current | |
| MCFaults | DINT | Decimal | 2122 | MC Faults | |
| SCRFault | 0 | BOOL | Decimal | 2122.0 | SCR Fault | 
| MContLost | 1 | BOOL | Decimal | 2122.1 | M Cont Lost | 
| ACLineSync | 3 | BOOL | Decimal | 2122.3 | AC Line Sync | 
| InstOvrCurr | 4 | BOOL | Decimal | 2122.4 | InstOvr Curr | 
| ConductionTO | 5 | BOOL | Decimal | 2122.5 | ConductionTO | 
| FieldLoss | 6 | BOOL | Decimal | 2122.6 | Field Loss | 
| TachLoss | 7 | BOOL | Decimal | 2122.7 | Tach Loss | 
| TachWireOpn | 8 | BOOL | Decimal | 2122.8 | TachWire Opn | 
| ResolverCard | 9 | BOOL | Decimal | 2122.9 | ResolverCard | 
| OverSpeed | 10 | BOOL | Decimal | 2122.10 | Over Speed | 
| PwrTechCard | 11 | BOOL | Decimal | 2122.11 | PwrTech Card | 
| PMIPwrSply | 12 | BOOL | Decimal | 2122.12 | PMI Pwr Sply | 
| PMIBus | 13 | BOOL | Decimal | 2122.13 | PMI Bus | 
| PMICommLoss | 15 | BOOL | Decimal | 2122.15 | PMI CommLoss | 
| MCWarnings | DINT | Decimal | 2123 | MC Warnings | |
| BrdgNotFirng | 0 | BOOL | Decimal | 2123.0 | BrdgNotFirng | 
| LowACLine | 1 | BOOL | Decimal | 2123.1 | Low AC Line | 
| LineSyncLoss | 3 | BOOL | Decimal | 2123.3 | LineSyncLoss | 
| CurrRefLim | 4 | BOOL | Decimal | 2123.4 | Curr Ref Lim | 
| IDTestAbort | 5 | BOOL | Decimal | 2123.5 | ID TestAbort | 
| FieldOvrCurr | 6 | BOOL | Decimal | 2123.6 | FieldOvrCurr | 
| ArmFdbkRev | 7 | BOOL | Decimal | 2123.7 | Arm Fdbk Rev | 
| CTFdbkRev | 8 | BOOL | Decimal | 2123.8 | CT Fdbk Rev | 
| PMIFanLoss | 12 | BOOL | Decimal | 2123.12 | PMI Fan Loss | 
| RailIOComm | 13 | BOOL | Decimal | 2123.13 | Rail IO Comm | 
| PMICommSync | 14 | BOOL | Decimal | 2123.14 | PMI CommSync | 
| PMIComm | 15 | BOOL | Decimal | 2123.15 | PMI Comm | 
| MtrPositFdbk | DINT | Decimal | 762 | Mtr Posit Fdbk | |
| ActMotorPosit | DINT | Decimal | 763 | Act Motor Posit | |
| PositionStatus | DINT | Binary | 741 | Position Status | |
| XIGainLLim | 0 | BOOL | Decimal | 741.0 | X IGain LLim | 
| XIGainHLim | 1 | BOOL | Decimal | 741.1 | X IGain HLim | 
| XSpdLLim | 2 | BOOL | Decimal | 741.2 | X Spd LLim | 
| XSpdHLim | 3 | BOOL | Decimal | 741.3 | X Spd HLim | 
| PositWatch1 | 8 | BOOL | Decimal | 741.8 | Posit Watch1 | 
| PositWatch2 | 9 | BOOL | Decimal | 741.9 | Posit Watch2 | 
| InPosition | 10 | BOOL | Decimal | 741.10 | In Position | 
| PositionError | DINT | Decimal | 769 | Position Error | |
| UserDefinedRealData | REAL[4] | Float | User-defined | User-defined Real Data | |
| UserDefinedIntegerData | DINT[2] | Decimal | User-defined | User-defined Integer Data | 
* Location of these bits are fixed for DPI.
** Decimal number displayed as 10x actual value (e.g., 15 represents 1.5 amps).
Module-defined Data Type: AB: DMD30_POSITIONCONTROL:O:0
Comm Format: Position Control
| Member Name | Bit in Previous Word | Data Type | Default Display Style | Drive Parameter | Description | 
| LogicCommand | DINT | Binary | 151 | Logic Command | |
| SpdRampDsbl | 0 | BOOL | Decimal | 151.0 | SpdRamp Dsbl | 
| SpdSCrvEn | 1 | BOOL | Decimal | 151.1 | Spd S Crv En | 
| TachLossRst | 2 | BOOL | Decimal | 151.2 | TachLoss Rst | 
| TimeAxisEn | 3 | BOOL | Decimal | 151.3 | Time Axis En | 
| MCAtuneEn | 4 | BOOL | Decimal | 151.4 | MC Atune En | 
| MtrInertEn | 8 | BOOL | Decimal | 151.8 | Mtr Inert En | 
| SysInertEn | 9 | BOOL | Decimal | 151.9 | Sys Inert En | 
| InertiaComp | 10 | BOOL | Decimal | 151.10 | Inertia Comp | 
| FrictComp | 11 | BOOL | Decimal | 151.11 | Frict Comp | 
| ProcsTrimEn | 12 | BOOL | Decimal | 151.12 | ProcsTrim En | 
| NormalStop | 16 | BOOL | Decimal | *Logic Parser | Normal Stop | 
| Start | 17 | BOOL | Decimal | *Logic Parser | Start | 
| Jog1 | 18 | BOOL | Decimal | *Logic Parser | Jog 1 | 
| ClearFault | 19 | BOOL | Decimal | *Logic Parser | Clear Fault | 
| UnipolFwd | 20 | BOOL | Decimal | *Logic Parser | Unipol Fwd | 
| UnipolRev | 21 | BOOL | Decimal | *Logic Parser | Unipol Rev | 
| Jog2 | 23 | BOOL | Decimal | *Logic Parser | Jog 2 | 
| CurrLimStop | 24 | BOOL | Decimal | *Logic Parser | CurrLim Stop | 
| CoastStop | 25 | BOOL | Decimal | *Logic Parser | Coast Stop | 
| PositionEn | 26 | BOOL | Decimal | *Logic Parser | Position En | 
| FieldEn | 30 | BOOL | Decimal | *Logic Parser | Field En | 
| SpeedRef1 | REAL | Float | 10 | Speed Ref 1 | |
| TorqueRef1 | REAL | Float | 111 | Torque Ref 1 | |
| SpdTorqModeSel | DINT | Decimal | 110 | Spd/Torq ModeSel | |
| TorqueStep | REAL | Float | 116 | Torque Step | |
| SpdRegDroop | REAL | Float | 86 | Spd Reg Droop | |
| PositionControl | DINT | Binary | 740 | Position Control | |
| SpeedOutEn | 1 | BOOL | Decimal | 740.1 | Speed Out En | 
| IntegEn | 2 | BOOL | Decimal | 740.2 | Integ En | 
| IntegHold | 3 | BOOL | Decimal | 740.3 | Integ Hold | 
| XOffsetPol | 4 | BOOL | Decimal | 740.4 | X Offset Pol | 
| XOffsetRef | 5 | BOOL | Decimal | 740.5 | X Offset Ref | 
| ActPositRst | 6 | BOOL | Decimal | 740.6 | ActPosit Rst | 
| PtPtReRef | 10 | BOOL | Decimal | 740.10 | Pt-Pt ReRef | 
| InterpRev | 13 | BOOL | Decimal | 740.13 | Interp Rev | 
| XWatch1En | 16 | BOOL | Decimal | 740.16 | X Watch1 En | 
| XWatch1Dir | 17 | BOOL | Decimal | 740.17 | X Watch1 Dir | 
| XWatch2En | 18 | BOOL | Decimal | 740.18 | X Watch2 En | 
| XWatch2Dir | 19 | BOOL | Decimal | 740.19 | X Watch2 Dir | 
| CoarsePositTrgt | DINT | Decimal | 748 | CoarsePosit Trgt | |
| PtPtPositRef | DINT | Decimal | 758 | Pt-Pt Posit Ref | |
| PositRefSel | DINT | Decimal | 742 | Posit Ref Sel | |
| PositOffset1 | DINT | Decimal | 753 | Posit Offset 1 | |
| UserDefinedRealData | REAL[3] | Float | User-defined | User-defined Real Data | |
| UserDefinedIntegerData | DINT[2] | Decimal | User-defined | User-defined Integer Data | 
* The output from the Logic Parser is mapped to parameter 152, bits 16-31.
Module-defined Data Type: AB: DMD30_GENERIC:I:0
Comm Format: User-defined Control
| Member Name | Bit in Previous Word | Data Type | Default Display Style | Drive Parameter | Description | 
| LogicStatus | DINT | Binary | 155 | Logic Status | |
| Enabled | 0* | BOOL | Decimal | 155.0 | Enabled | 
| Running | 1* | BOOL | Decimal | 155.1 | Running | 
| CommandDir | 2* | BOOL | Decimal | 155.2 | Command Dir | 
| ActualDir | 3* | BOOL | Decimal | 155.3 | Actual Dir | 
| Accelerating | 4 | BOOL | Decimal | 155.4 | Accelerating | 
| Decelerating | 5 | BOOL | Decimal | 155.5 | Decelerating | 
| Jogging | 6 | BOOL | Decimal | 155.6 | Jogging | 
| Faulted | 7* | BOOL | Decimal | 155.7 | Faulted | 
| Alarm | 8* | BOOL | Decimal | 155.8 | Alarm | 
| FlashMode | 9* | BOOL | Decimal | 155.9 | Flash Mode | 
| RunReady | 10 | BOOL | Decimal | 155.10 | Run Ready | 
| AtLimit | 11 | BOOL | Decimal | 155.11 | At Limit | 
| TachLossSw | 12 | BOOL | Decimal | 155.12 | Tach Loss Sw | 
| AtZeroSpd | 13 | BOOL | Decimal | 155.13 | At Zero Spd | 
| AtSetptSpd | 14 | BOOL | Decimal | 155.14 | At Setpt Spd | 
| AtSetpt1 | 16 | BOOL | Decimal | 155.16 | At Setpt 1 | 
| AboveSetpt2 | 17 | BOOL | Decimal | 155.17 | Above Setpt2 | 
| MCEnAck | 18 | BOOL | Decimal | 155.18 | MC En Ack | 
| MCCommis | 19 | BOOL | Decimal | 155.19 | MC Commis | 
| SpdCommis | 20 | BOOL | Decimal | 155.20 | Spd Commis | 
| TorqueMode | 22 | BOOL | Decimal | 155.22 | Torque Mode | 
| SpeedMode | 23 | BOOL | Decimal | 155.23 | Speed Mode | 
| PositionMode | 24 | BOOL | Decimal | 155.24 | PositionMode | 
| StartActive | 25 | BOOL | Decimal | 155.25 | Start Active | 
| CommandRun | 26 | BOOL | Decimal | 155.26 | Command Run | 
| FieldCurrOn | 30 | BOOL | Decimal | 155.30 | FieldCurr On | 
| UserDefinedRealData | REAL[12] | Float | User-defined | User-defined Real Data | |
| UserDefinedIntegerData | DINT[3] | Decimal | User-defined | User-defined Integer Data | 
* Location of these bits are fixed for DPI.
Module-defined Data Type: AB: DMD30_GENERIC:O:0
Comm Format: User-defined Control
| Member Name | Bit in Previous Word | Data Type | Default Display Style | Drive Parameter | Description | 
| LogicCommand | DINT | Binary | 151 | Logic Command | |
| SpdRampDsbl | 0 | BOOL | Decimal | 151.0 | SpdRamp Dsbl | 
| SpdSCrvEn | 1 | BOOL | Decimal | 151.1 | Spd S Crv En | 
| TachLossRst | 2 | BOOL | Decimal | 151.2 | TachLoss Rst | 
| TimeAxisEn | 3 | BOOL | Decimal | 151.3 | Time Axis En | 
| MCAtuneEn | 4 | BOOL | Decimal | 151.4 | MC Atune En | 
| MtrInertEn | 8 | BOOL | Decimal | 151.8 | Mtr Inert En | 
| SysInertEn | 9 | BOOL | Decimal | 151.9 | Sys Inert En | 
| InertiaComp | 10 | BOOL | Decimal | 151.10 | Inertia Comp | 
| FrictComp | 11 | BOOL | Decimal | 151.11 | Frict Comp | 
| ProcsTrimEn | 12 | BOOL | Decimal | 151.12 | ProcsTrim En | 
| NormalStop | 16 | BOOL | Decimal | *Logic Parser | Normal Stop | 
| Start | 17 | BOOL | Decimal | *Logic Parser | Start | 
| Jog1 | 18 | BOOL | Decimal | *Logic Parser | Jog 1 | 
| ClearFault | 19 | BOOL | Decimal | *Logic Parser | Clear Fault | 
| UnipolFwd | 20 | BOOL | Decimal | *Logic Parser | Unipol Fwd | 
| UnipolRev | 21 | BOOL | Decimal | *Logic Parser | Unipol Rev | 
| Jog2 | 23 | BOOL | Decimal | *Logic Parser | Jog 2 | 
| CurrLimStop | 24 | BOOL | Decimal | *Logic Parser | CurrLim Stop | 
| CoastStop | 25 | BOOL | Decimal | *Logic Parser | Coast Stop | 
| PositionEn | 26 | BOOL | Decimal | *Logic Parser | Position En | 
| FieldEn | 30 | BOOL | Decimal | *Logic Parser | Field En | 
| UserDefinedRealData | REAL[12] | Float | User-defined | User-defined Real Data | |
| UserDefinedIntegerData | DINT[3] | Decimal | User-defined | User-defined Integer Data | 
* The output from the Logic Parser is mapped to parameter 152, bits 16-31.
Module-defined Data Type: AB: DMD30_CUSTOMUSER_DEFINED:I:0
Comm Format: Custom User-defined Control
| Member Name | Bit in Previous Word | Data Type | Default Display Style | Drive Parameter | Description | 
| LogicStatus | DINT | Binary | Logic Status | ||
| UserDefinedRealData | REAL[8] | Float | User-defined | User-defined Real Data | |
| UserDefinedIntegerData | DINT[7] | Decimal | User-defined | User-defined Integer Data | 
Module-defined Data Type: AB: DMD30_CUSTOMUSER_DEFINED:O:0
Comm Format: Custom User-defined Control
| Member Name | Bit in Previous Word | Data Type | Default Display Style | Drive Parameter | Description | 
| LogicCommand | DINT | Binary | Logic Command | ||
| UserDefinedRealData | REAL[8] | Float | User-defined | User-defined Real Data | |
| UserDefinedIntegerData | DINT[7] | Decimal | User-defined | User-defined Integer Data | 