Features that are not supported in version 5.0 or earlier

These version 5.10 features are not supported in FactoryTalk View ME Station version 5.0 or earlier. The right column describes how to remove or replace the features.
To remove or replace this feature
Do this
Tag or expression assigned to the
Close an On Top Display
, or
Close All On Top Displays
connections
Delete the tag or expression assigned on the
Display
tab of the
Global Connections
editor.
Tag or expression assigned to the
Parameter File
, or
Use Parameter List
connections
Delete the tag or expression assigned on the
Display
tab of the
Global Connections
editor.
Tag or expression assigned to one or more of the
Parameter Tag #1-10
connections
Delete the tag or expression on the
Display
tab of the
Global Connections
editor.
Parameter list property assigned in the
Properties
dialog box of a Display List Selector, Goto display button, or Logout button graphic object
In the object’s
Properties
dialog box, clear the
Parameter list
assignment.
Parameter list
property assigned to the display specified for auto logout in
Project Settings
On the
Runtime
tab of the
Project Settings
dialog box, clear the
Parameter list
assignment.
Parameter list
assigned to the
Initial graphic
property in the Startup editor
In the
Startup
editor, clear the
Parameter list assignment
for the
Initial graphic
.
Use variable minimum/maximum
property assigned to
Numeric Input Cursor Point
or Numeric Input Enable object
On the
Numeric
tab of the object’s
Properties
dialog box, clear the
Use variable minimum/maximum
property.
Caption on Keypad
property assigned to
Numeric Input Cursor Point
object
On the
Numeric
tab of the object’s
Properties
dialog box, set the
Caption on keypad/scratchpad
property to blank.
Minimum
or
Maximum
connections assigned for
Numeric Input Cursor Point
or
Numeric Input Enable object
On the
Connections
tab of the object’s
Properties
dialog box, delete the tag or expression assigned to the
Minimum
or
Maximum
connection.
Use variable ramp
or
Use variable limit
property set for the
Ramp
button object
On the
General
tab of the object’s
Properties
dialog box, clear the
Use variable lower/upper limit
and
Use variable ramp value
properties.
Ramp
or
Limit
connection set for the
Ramp
button object
On the
Connections
tab of the object’s
Properties
dialog box, delete the tag or expression assigned to the
Ramp
or
Limit
connection.
The application is designated as a Compact Machine Edition application in
Project Settings
On the
General
tab of the
Project Settings
dialog box, clear the
Compact Machine Edition application
checkbox.