Create the interface elements
    Create a linear gauge, a button, and a data grid.
- Create a linear gauge:
- InProject view, right-clickMainWindow (type)and select .
 - InProperties, create a dynamic link betweenValueand .For more information about dynamic links, see Create dynamic links.
 
 - Create a data grid:
- InProject view, right-clickMainWindow (type)and select .
 - InProperties, create a dynamic link betweenModeland .
 - SetQuerytoSELECT * FROM "DataLogger1" ORDER BY "Timestamp" DESC.
 
 - Configure data grid columns:
- InProperties, underColumns, double-clickDataGridColumn1and enterTimestampColumn.
 - UnderDataItemTemplate, create a dynamic link between the columnTextproperty and .NOTE: EnterTimestampin theInsert the dynamic link sub-path...field.For more information about dynamic links, see Create dynamic links.
 - SetTitletoTimestamp.
 - Next toColumns, selectand select
Text column. - InProperties, underColumns, double-clickDataGridColumn1and enterVariableValueColumn.
 - UnderDataItemTemplate, create a dynamic link between the columnTextproperty and .NOTE: EnterVariable1in theInsert the dynamic link sub-path...field.For more information about dynamic links, see Create dynamic links.
 - SetTitletoVariable value.
 
 - Create a refresh button:
- InProject view, right-clickMainWindow (type)and select .
 - InProperties, setTexttoRefresh Data.
 - InEvents, next toMouseClick event, selectand select

 
 