InformationModel.MakeObjectType(browseName, superTypeId)

Creates a project object type derived from the type indicated in the second argument (supertype) and returns a corresponding
IUAObjectType
C# object.
static IUAObjectType MakeObjectType(QualifiedName
browseName
, NodeId
superTypeId
);

Arguments

browseName
(QualifiedName)
The
BrowseName
of the new object.
superTypeId
(NodeId)
The
NodeID
of the type from which the new object is derived.

Returns

IUAObject
A C# object that corresponds to the project object created.

Example

The following example shows an API that creates a
SpecialMotor (type)
object derived from
Motor (type)
, searched with the
Find
method, and then specified using NodeID:
var supertype = Project.Current.Find("Motor"); Owner.Add(InformationModel.MakeObjectType("SpecialMotor", supertype.NodeId));