Sample Queries
The following table displays the sample queries for the Assets, Timeseries, Timeseries Data Points, Sequences, Relationships, Datasets, and Events table:
S.No | DataMosaix Resource | SQL Query |
---|---|---|
1 | Asset | SELECT * FROM public.assets WHERE name like 'testasset-37%' OR name like 'testtraining-%' OR name = 'test-13 on "asset-1"'; |
2 | Asset | SELECT * FROM public.assets WHERE name IN ( 'testasset-37 on "test-1"', 'testtraining-01 on "test-1"', 'asset-13 on "test-1"'); |
3 | Timeseries | SSELECT * FROM timeseries WHERE externalId LIKE 'ext%'; |
4 | Timeseries | select * from timeseries where name = '<timeseriesName>' |
5 | Timeseries Data Points | SELECT * FROM public.timeseries_datapoints WHERE timeseriesid = <timeseriesid>; SELECT * FROM public.timeseries_datapoints WHERE externalid = '<externalid>'; |
6 | Timeseries Data Points | select * from public.timeseries_datapoints where (externalid= '<externalid>' AND isstring = '<boolean>' ) OR ( timestamputc BETWEEN '2024-08-26 08:30:49.039' and '2024-05-26 08:30:49.039' AND valuenumeric > 100) |
7 | Timeseries and Assets Join | select * from public.timeseries join public.assets on public.timeseries.assetId = public.assets.id; |
8 | Timestamp Functions (NOW() and CURRENT_TIMESTAMP()) | SELECT NOW(); SELECT NOW() - INTERVAL 1 hour; SELECT CURRENT_TIMESTAMP(); SELECT CURRENT_TIMESTAMP() - INTERVAL 1 hour; |
9 | Sequences | SELECT id, type, createdTime, lastUpdatedTime, externalId, assetId, name, description, dataSetId FROM public.sequences; |
10 | Relationships | SELECT * FROM public.relationships WHERE sourceType = 'asset'; |
11 | Datasets | [SELECT * FROM public.dataset WHERE externalId LIKE 'prefix%';] |
12 | Events | SELECT * FROM public.events WHERE (description LIKE 'P%' OR externalId = 'f8b2de96-39bd-46c7-9c88-bbb949e0e9b2') AND datasetId = 3701037531680276; |
13 | Datasets (Inner Join) | SELECT d.id, d.name FROM public.datasets d JOIN public.datasets p ON d.externalid = p.externalid; |
Provide Feedback