timeseries can have either numeric or string data, so there are 2 columns for each data type. The value will be present in any one of them. This table will return 0 rows if queried without a filter on internal or external id. So timeseries_ID or external_ID is mandatory in where clause to fetch the data. By default, if you do not specify any time filters based on column "timestamp_utc", queries will return records for the last 24 hours. The
timeseries_datapoints
tables include the actual data points for a timeseries. This table has the following columns:
Timeseries Data Table
Column Name
Data Type
Description
timeseries_id
BIGINT
Internal ID of the timeseries.
external_id
VARCHAR
External ID of the timeseries.
timestamp_utc
DATETIME
Recorded timestamp of the data points.
value_numeric
DOUBLE
The numeric value of the data point if is_string is false otherwise null.
value_string
TEXT
The string value of the data point if is_string is true otherwise null
is_step
BOOL
TRUE if data point is a step
is_string
BOOL
TRUE if data point is a string