Audited FactoryTalk Batch Equipment Editor events

This section describes the set of audit messages generated by
FactoryTalk Batch Equipment Editor
. Not all user actions are audited; for example,
View
menu changes and
Options
menu changes do not generate audit messages. The following events are audited when the area model is saved.
Audited events when the area model is saved
Message Type
Event
Area Model
Invoke
FactoryTalk Batch Equipment Editor
Open an existing area model
Create a new area model
Save an area model
Edit/update an area model property
Delete an area model
Add a signature template
Delete a signature template
Update a signature template
Enable/disable recipe approvals
Enable/disable recipe versioning
Update a command verification policy
Area Model Security
Security authority is configured for an area model
Security authority identifier (SAI) is set or removed
Security authority configuration change is accepted by user
Security authority changes are saved to the area model
Data Server
Add an
OPC®
server
Delete an OPC server
Edit/update an OPC server property
Add a
Logix5000™
CIP™
server
Delete a Logix5000 CIP server
Edit a Logix5000 CIP server
Add an FTD server
Delete an FTD server
Edit/update an FTD server property
Enumeration Set
Create an enumeration set
Delete an enumeration set
Edit/update an enumeration set property
Enumeration
Add an enumeration
Delete an enumeration
Edit/update an enumeration property
Resource Class
Add a resource class
Delete a resource class
Edit/update a resource class property
Resource
Add a resource
Delete a resource
Edit/update a resource property
Process Cell Class
Add a process cell class
Copy a process cell class
Delete a process cell class
Edit/update a process cell class property
Process Cell
Add a process cell
Copy a process cell
Delete a process cell
Edit/update a process cell property
Unit Attribute
Add a unit attribute
Delete a unit attribute
Edit/update a unit attribute property
Unit
Add a unit
Copy a unit
Edit a unit
Delete a unit
Edit/update a unit property
Global Unit Binding Requirements
Add global unit attribute
Edit global unit attribute
Delete global unit attribute
Unit Flow Path
Link units with a flow path
Unlink units with a flow path
Equipment Phase Class (Recipe Phase)
Add an equipment phase class
Copy an equipment phase class
Delete an equipment phase class
Edit/update an equipment phase class property
Edit/update an equipment phase class control strategy set of parameters
Edit/update an equipment phase class optional material parameters property
Edit/update an equipment phase class control strategy set of reports
Edit/update an equipment phase class control strategy
Equipment Phase
Add an equipment phase
Copy an equipment phase
Delete an equipment phase
Edit/update an equipment phase property
Edit/update an equipment phase’s server property
Reset an equipment phase’s tags to default values
Share an equipment phase between units
Recipe Parameter
Add a recipe parameter
Delete a recipe parameter
Edit/update a recipe parameter property
Recipe Approval Step
Add a recipe approval step
Delete a recipe approval step
Edit/update a recipe approval step
Report Parameter
Add a report parameter
Delete a recipe parameter
Edit/update a recipe parameter property
Phase Message
Add a phase message
Delete a phase message
Edit/update a phase message property
Synchronize
Synchronize a phase
Tag Class
Add a tag class
Delete a tag class
Edit/update a tag class property
Unit Attribute Tag
Add a unit attribute tag
Delete a unit attribute tag
Edit/update a unit attribute tag property
Container Association
Add a container association
Delete a container association
Edit/update a container association property
Instruction Configuration
Edit/update an instruction configuration property
Phase Tag
Edit/update a phase tag property