Diagnostics dialog parameters
The Diagnostics dialog for
Axes
and AxisXX
views include these
parameters:
Parameter | Description |
|---|---|
Enabled | Displays whether the Axis is enabled. |
Fault Exists | Displays whether a fault is present. |
Data Uncertain | Displays the module is operating outside the designed operating
range, or data is under manual or override control. |
Field Power | Displays whether field power is present on the Axis. |
Field Power On Timestamp | Displays the timestamp of the last time field power turned on in
YYYY-MM-DD-HH:mm:SS.mmm format.
You can see a valid time or None if no event time is
recorded. |
Field Power Off Timestamp | Displays the timestamp of the last time field power turned off in
YYYY-MM-DD-HH:mm:SS.mmm format.
You can see a valid time or None if no event time is
recorded. |
Short Circuit Fault | Displays whether a short circuit fault is present on the
axis. |
Short Circuit Fault Timestamp | Displays the timestamp of the last short circuit fault in
YYYY-MM-DD-HH:mm:SS.mmm format.
You can see a valid time or None if no event time was
recorded. |
Over Temperature | Displays whether an over temperature condition is present on the
axis. |
Over Temperature Timestamp | Displays the timestamp of the last over temperature condition in
YYYY-MM-DD-HH:mm:SS.mmm format.
You can see a valid time or None if no event time was
recorded. |
Critical Temperature Fault | Displays whether a critical temperature fault is present on the
axis. |
Critical Temperature Fault Timestamp | Displays the timestamp of the last critical temperature fault in
YYYY-MM-DD-HH:mm:SS.mmm format.
You can see a valid time or None if no event time was
recorded. |
Motor Torque Disabled | Displays whether a motor torque off condition is present on the
axis. |
Motor Torque Disabled Timestamp | Displays the timestamp of the last motor torque off condition in
YYYY-MM-DD-HH:mm:SS.mmm format.
You can see a valid time or None if no event time was
recorded. |
External Brake Fault | Displays whether the external brake for the axis has faulted. |
External Brake Fault Timestamp | Displays the timestamp of the last external brake fault in
YYYY-MM-DD-HH:mm:SS.mmm format.
You can see a valid time or None if no event time was
recorded. |
Positive Overtravel | Displays whether a positive overtravel condition is present on
the axis. |
Positive Overtravel Timestamp | Displays the timestamp of the last positive overtravel condition
in YYYY-MM-DD-HH:mm:SS.mmm format.
You can see a valid time or None if no event time was
recorded. |
Negative Overtravel | Displays whether a negative overtravel condition is present on
the axis. |
Negative Overtravel Timestamp | Displays the timestamp of the last negative overtravel condition
in YYYY-MM-DD-HH:mm:SS.mmm format.
You can see a valid time or None if no event time was
recorded. |
Internal Fault | Displays whether an internal fault is present on the axis. |
Internal Fault Timestamp | Displays the timestamp of the last internal fault in
YYYY-MM-DD-HH:mm:SS.mmm format.
You can see a valid time or None if no event time was
recorded. |