Device-defined data types (Stratix 5400 16 Port Managed Switch)

The tables below list and describe device-defined data types for the Stratix 5400 16 Port Managed Switch. These tables include information for input (as indicated by an I) and output (as indicated by an O).
Device-defined data type: AB:STRATIX_5400_16PORT_MANAGED:I:0
Member Name
Type
Default Display Style
Valid Values
Fault
DINT
Binary
AnyPortConnected
BOOL
Decimal
LinkStatus:0
PortGi1_1Connected
BOOL
Decimal
LinkStatus:1
PortGi1_2Connected
BOOL
Decimal
LinkStatus:2
PortGi1_3Connected
BOOL
Decimal
LinkStatus:3
PortGi1_4Connected
BOOL
Decimal
LinkStatus:4
PortFa1_5Connected
BOOL
Decimal
LinkStatus:5
PortFa1_6Connected
BOOL
Decimal
LinkStatus:6
PortFa1_7Connected
BOOL
Decimal
LinkStatus:7
PortFa1_8Connected
BOOL
Decimal
LinkStatus:8
PortFa1_9Connected
BOOL
Decimal
LinkStatus:9
PortFa1_10Connected
BOOL
Decimal
LinkStatus:10
PortFa1_11Connected
BOOL
Decimal
LinkStatus:11
PortFa1_12Connected
BOOL
Decimal
LinkStatus:12
PortFa1_13Connected
BOOL
Decimal
LinkStatus:13
PortFa1_14Connected
BOOL
Decimal
LinkStatus:14
PortFa1_15Connected
BOOL
Decimal
LinkStatus:15
PortFa1_16Connected
BOOL
Decimal
LinkStatus:16
AnyPortUnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:0
PortGi1_1UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:1
PortGi1_2UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:2
PortGi1_3UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:3
PortGi1_4UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:4
PortFa1_5UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:5
PortFa1_6UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:6
PortFa1_7UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:7
PortFa1_8UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:8
PortFa1_9UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:9
PortFa1_10UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:10
PortFa1_11UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:11
PortFa1_12UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:12
PortFa1_13UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:13
PortFa1_14UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:14
PortFa1_15UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:15
PortFa1_16UnauthorizedDevice
BOOL
Decimal
UnauthorizedDevice:16
AnyPortThreshold
BOOL
Decimal
ThresholdExceeded:0
PortGi1_1Threshold
BOOL
Decimal
ThresholdExceeded:1
PortGi1_2Threshold
BOOL
Decimal
ThresholdExceeded:2
PortGi1_3Threshold
BOOL
Decimal
ThresholdExceeded:3
PortGi1_4Threshold
BOOL
Decimal
ThresholdExceeded:4
PortFa1_5Threshold
BOOL
Decimal
ThresholdExceeded:5
PortFa1_6Threshold
BOOL
Decimal
ThresholdExceeded:6
PortFa1_7Threshold
BOOL
Decimal
ThresholdExceeded:7
PortFa1_8Threshold
BOOL
Decimal
ThresholdExceeded:8
PortFa1_9Threshold
BOOL
Decimal
ThresholdExceeded:9
PortFa1_10Threshold
BOOL
Decimal
ThresholdExceeded:10
PortFa1_11Threshold
BOOL
Decimal
ThresholdExceeded:11
PortFa1_12Threshold
BOOL
Decimal
ThresholdExceeded:12
PortFa1_13Threshold
BOOL
Decimal
ThresholdExceeded:13
PortFa1_14Threshold
BOOL
Decimal
ThresholdExceeded:14
PortFa1_15Threshold
BOOL
Decimal
ThresholdExceeded:15
PortFa1_16Threshold
BOOL
Decimal
ThresholdExceeded:16
AllPortsUtilization
SINT
Decimal
PortGi1_1Utilization
SINT
Decimal
PortGi1_2Utilization
SINT
Decimal
PortGi1_3Utilization
SINT
Decimal
PortGi1_4Utilization
SINT
Decimal
PortFa1_5Utilization
SINT
Decimal
PortFa1_6Utilization
SINT
Decimal
PortFa1_7Utilization
SINT
Decimal
PortFa1_8Utilization
SINT
Decimal
PortFa1_9Utilization
SINT
Decimal
PortFa1_10Utilization
SINT
Decimal
PortFa1_11Utilization
SINT
Decimal
PortFa1_12Utilization
SINT
Decimal
PortFa1_13Utilization
SINT
Decimal
PortFa1_14Utilization
SINT
Decimal
PortFa1_15Utilization
SINT
Decimal
PortFa1_16Utilization
SINT
Decimal
MajorAlarmRelay
BOOL
Decimal
AlarmRelay:0
MinorAlarmRelay
BOOL
Decimal
AlarmRelay:1
MulticastGroupsActive
DINT
Binary
Device-defined data type: AB:STRATIX_5400_16PORT_MANAGED:O:0
This device-defined data type is created for the device when
Data Connection
is
Data
.
Member Name
Type
Default Display Style
Valid Values
AllPortsDisable
BOOL
Decimal
DisablePort:0
PortGi1_1Disable
BOOL
Decimal
DisablePort:1
PortGi1_2Disable
BOOL
Decimal
DisablePort:2
PortGi1_3Disable
BOOL
Decimal
DisablePort:3
PortGi1_4Disable
BOOL
Decimal
DisablePort:4
PortFa1_5Disable
BOOL
Decimal
DisablePort:5
PortFa1_6Disable
BOOL
Decimal
DisablePort:6
PortFa1_7Disable
BOOL
Decimal
DisablePort:7
PortFa1_8Disable
BOOL
Decimal
DisablePort:8
PortFa1_9Disable
BOOL
Decimal
DisablePort:9
PortFa1_10Disable
BOOL
Decimal
DisablePort:10
PortFa1_11Disable
BOOL
Decimal
DisablePort:11
PortFa1_12Disable
BOOL
Decimal
DisablePort:12
PortFa1_13Disable
BOOL
Decimal
DisablePort:13
PortFa1_14Disable
BOOL
Decimal
DisablePort:14
PortFa1_15Disable
BOOL
Decimal
DisablePort:15
PortFa1_16Disable
BOOL
Decimal
DisablePort:16