Event0x view parameters
    The 
Event0x
 view includes these parameters:Parameter  | Description  | Member Name  | Value  | 
|---|---|---|---|
Enable Event  | Determines the corresponding event trigger definition to activate. Events are triggered once when conditions match the definition.  | EO.Event0x.En  | 
  | 
Latch Event  | Determines whether an event is latched until it is acknowledged.  | EO.Event0x.LatchEvent  | 
  | 
Enable Independent Triggers  | Determines whether each condition indicated in the Event trigger definition can initiate an event independently.  | EO.Event0x. IndependentConditionTriggerEn  | 
  | 
Trigger Event  | Triggers an event each time a condition change results in conditions: 
  | EO.Event0x.EventRisingEn EO.Event0x.EventFallingEn  | When  Enable Independent Point Triggers  = Checked (EventRisingEn, EventFallingEn)
 When  Enable Independent Point Triggers  = Unchecked(EventRisingEn, EventFallingEn) 
  | 
Participate in Event Trigger  | Indicates that the specified point participates in the Event trigger definition for the event.  | EO.Event0x.Pt0xDataSelect  | 
  | 
State Transition  | Determines whether the specified point transitions after the event.  | EO.Event0x.Pt0xDataValue  | If  Enable Independent Point Triggers  is unchecked:
 If  Enable Independent Point Triggers  is checked:
  | 
Provide Feedback