Log Entries

For
Trusted®
projects, the Activity Logger lists these types of actions and modifications. All entries include the date, time, and user account that performed the action or modification.
Log Entry
Description
Create Project "
ProjectName
" -
ProjectComment
Create the project or import the legacy
Trusted
Toolset project:
  • Includes the comment for the project
  • Truncates to a maximum length of 256 bytes
Rename project "
ProjectName
" to "
NewProjectName
"
Save the project "
ProjectName
" as "
NewProjectName
". The new project loads in the
Application View
.
Set project password
Set the project password.
Change project password
Modify the project password.
Remove project password
Remove the project password.
Modify project description
Modify the project description.
Make application code
Code result when compiling the application code:
  • No error detected
  • Error(s) detected
APPLICATION VERSION NUMBER = #
Version number of the application.
Verify program '
ProgramName
'
Code result when verifying the Program Organization Unit (POU):
  • No error detected
  • Error(s) detected
Clean application code
Clean the application code.
Start application
Successfully start the application.
A "Start Application" entry does not appear in the log if the controller initiates the process. For example, the controller starts the application after the download.
Stop application
Successfully stop the application.
A "Stop Application" entry appears in the log after the user confirms they want to stop running the application, for example, before the download.
Application download successful
Application download failed
Success or failure downloading the application to the
Trusted
controller.
Application update successful
Application update failed
Success or failure updating the application on the
Trusted
controller.
  • WARNING: Cannot determine if on-line update is possible
  • WARNING: On-line update is not possible
On-line update situation:
  • Unable to determine if an on-line update is possible
  • On-line update is not possible
  • Target requires APPLICATION VERSION NUMBER = # for update
Application version number required to perform an update.
  • On-line update will use normal method
  • On-line update will use Intelligent Update method
Method to use for on-line update:
  • Normal update
  • Intelligent update
Add I/O device "
I/ODeviceName
"
Add the specified I/O device.
Remove I/O device "
I/ODeviceName
"
Remove the specified I/O device.
Create conversion table(s)
Create one or more conversion tables.
Delete conversion table(s)
Delete one or more conversion tables.
Modify Cycle Timing (ms) device property
Modify the amount of time, in milliseconds, allocated to a cycle.
Modify Cycle Timing value to "
NewCycleTimingValue
"
Successfully modify the cycle timing, in milliseconds, on the Trusted controller.
Modify Memory for Retain device property
Modify the size of the memory space reserved for storing the values of retained variables.
Modify Nb stored errors device property
Modify the number of entries storing detected errors.
Modify Generate debug information device property
Enable or disable the generation of debug and monitoring information.
Modify Enable ISA68M device property
Enable or disable the ISA68M target.
Modify Enable Simulation device property
Enable or disable the application simulation.
Rename "
DeviceName
" to "
NewDeviceName
"
Rename the device.
Create "
POUlLanguage
"
"
POUType
" "
POUName
" in "
DeviceName
"
Create a program, function, or function block in the device. Details the programming language and name for the POU.
Delete "
POUName
" from "
DeviceName
"
Delete the POU from the device.
Delete "
POUName
" and "
Sub-programs
" from "
DeviceName
"
Delete the POU and its sub-programs from the device.
Create "
POULanguage" "POUType"
"
POUName
" in "
POUParentName
"
Create a child function for the parent program or function. Details the programming language and name for the POU.
Delete "
POUName
" from "
POUParentName
"
Delete the child function from the parent program or function.
Delete "
POUName
" and "
Sub-programs
" from "
POUParentName
"
Delete the child function from the parent program or function.
Modify "
POUName
"
Modify the POU contents.
Rename "
POUName
" to "
NewPOUName
"
Rename the POU to a new name.
Modify Description property for "
POUName
"
Modify the POU description.
Modify Comment property for "
POUName
"
Modify the POU comment.
Modify In-line property for "
POUName
"
Modify the in-line property for the POU.
Modify Modbus extended attributes for variable(s)
Modify the
Modbus®
extended attributes for one or more variables.
Add SOE extended attributes for variable(s)
Add SOE extended attributes to one or more variables.
Remove SOE extended attributes from variable(s)
Remove SOE extended attributes from one or more variables.
Export "
POUName
" to file "
FileName
"
Export the POU to the file.
Import
POULanguage POUType
"
POUName
"
Import the POU from the file.
Create global variable(s)
Create one or more global variables.
Delete global variable(s)
Delete one or more global variables.
Modify global variable(s)
Modify one or more global variables.
Create local variable(s) in "
POUName"
Create one or more local variables for the POU.
Delete local variable(s) from "
POUName"
Delete one or more local variables for the POU.
Modify local variable(s) in "
POUName
"
Modify one or more local variables for the POU.
Export global variable(s) to "
FileName
"
Export one or more global variables to the file.
Import global variable(s) from "
FileName
"
Import one or more global variables from the file.
Export local variable(s) from "
POUName
" to "
FileName
"
Export one or more local variables from the POU to the file.
Import local variable(s) from "
FileName
" into "
POUName
"
Import one or more local variables from the file into the POU.
Modify variable "
VariableName
" logical value to "
NewLogicalValue
"
Successfully modify the logical value of the variable.
Modify variable "
VariableName
" physical value to "
NewPhysicalValue
"
Successfully modify the physical value of the variable.
Lock variable "
VariableName
"
Successfully lock the variable.
Unlock variable "
VariableName
"
Successfully unlock the variable.
Create global defined word(s)
Create one or more global defined words.
Delete global defined word(s)
Delete one or more global defined words.
Modify global defined word(s)
Modify one or more global defined words.
Create local defined word(s) in "
POUName"
Create one or more local defined words for the POU.
Delete local defined word(s) from "
POUName"
Delete one or more local defined words for the POU.
Modify local defined word(s) in "
POUName
"
Modify one or more local defined words for the POU.
Validator # Exit without viewing all dependency information
Validator # Report printed to file
Validator # Report sent to printer
Validator # File scan complete
Validator # File scan failed or aborted
Validator # scanning TIC code: <
ProjectPath
>
Validator # scanning file: <
ProjectPath
>
Validate various actions performed with these validators: Cross Reference Checker (#1) or TIC Dependency Checker (#2).
Create ActivityLog_
YYYYMMDDHHMMSS
.xml backup file
Create a backup xml file for the existing Activity Logger entries and a new ActivityLog.xml file. The backup file name includes the year (YYYY), month (MM), day (DD), hour (HH), minute (MM), and second (SS) of file creation. A backup file is created when the ActivityLog.xml file is corrupted.
The default backup file is located in %USERPROFILE%\My Documents\SIS Workstation
<version>
\Projects\
ProjectName
\
ProjectName
\Backup
.
Activity Logger version is “
NewVersionValue
”
Report the Activity Logger version when the version changes.