By Phil Allen, Founder and Chairman of the Board, and Nick Schiltz, Content Marketing Specialist, Grace Technologies, Inc.

In the upcoming NFPA 70E® 2024 Edition the inclusion of the phrase "at each point of work" has prompted questions about the use of permanent electrical safety devices (PESDs) and absence of voltage testers (AVTs) for establishing an electrically safe work condition.

Qualified electrical workers are trained and intuitively know where to perform an absence of voltage test with portable test instruments within a given panel. However, best practices need to be established to verify that PESDs and AVTs are installed and terminated in the correct place within an electrical panel.

More specifically, verification is needed that test point PESDs remain compliant and relevant with the updated standard. By addressing the confusion and highlighting the importance of test point PESDs, we aim to demonstrate how users can confidently operate these devices in lockout/tagout (LOTO) procedures for reducing risk while establishing an electrically safe work condition.

The Significance of "Point of Work"

The concept of "point of work" is crucial for workplace safety, referring to the specific location where tasks are performed, and workers interact with tools, systems or materials. This intersection between the worker and the work environment holds significance for safety, performance and training.

The visibility of each isolation point for electrical energy is a fundamental electrical safety principle. Both PESDs and AVTs have a proven track record of reducing risks; partly because they’re engineered into electrical panels and inherently provide visibility of electrical energy.

Initially, voltage presence indicators provided visible indications of an electrical isolator's status. The introduction of AVTs and high impedance-protected test points has made absence of voltage testing a less risky way to establish an electrical work condition. In addition, the NFPA 70E 2024 Edition also recognizes test points as valid “Additional Safety-by-Design Methods” (NFPA 70E O.2.4.(13)).

Main Image
Enjoy The Journal’s Automation Chat Podcast

Join Theresa Houck, Executive Editor of The Journal From Rockwell Automation and Our PartnerNetwork™ magazine, as she talks with industrial automation and manufacturing leaders, implementers and other subject matter experts on the magazine’s “Automation Chat” podcast. Learn about the newest technologies and trends affecting your job every day.

Listen on your favorite podcast app or on the web, or watch their conversations on YouTube. And subscribe so you don’t miss an episode.

Listen Now Watch Now

While AVTs require no contact using a portable test instrument, test points use high-impedance protection to work hand-in-hand with a qualified worker’s electrical test tool. High-impedance-protected test points refer to specialized components or features incorporated into electrical systems or devices, typically found externally mounted onto electrical enclosures or panels.

AVTs are designed to provide a safe and reliable way to conduct voltage readings or absence of voltage testing without the risk of accidental contact with live electrical components. The high-impedance protection validates the test point has a high resistance to electrical current flow, minimizing the potential for electric shock or short circuits during testing procedures.

This protective measure helps safeguard personnel and equipment while performing critical electrical testing and maintenance activities.

NFPA 70E Revisions

Understanding the significance of "point of work" is the heartbeat of electrical safety. Incorporating visible PESDs, such as voltage presence indicators and absence of voltage test points, helps reduce risks during LOTO procedures.

New products have provided an additional method for absence of voltage testing but don’t replace nor negate previous methods using UL 61010 devices. The 2018 edition of NFPA 70E added an exception to account for AVTs. However, compliance using UL 61010 PESDs remains valid and requires no exception.

“Section [120.6] Item (7) does not prohibit the use of the proposed devices to extend test points when used with portable test instruments, and therefore no exception is needed." - NFPA 70E Technical Committee (Source: Public Input No. 367-NFPA 70E-2021, Committee EEW-AAA).

Through the revision cycles of NFPA 70E (2021 and 2024 editions), the 70E committee has affirmed the compliance of UL 61010 PESDs installed on electrical enclosures. These test points empower workers to conduct absence of voltage tests, aligning with NFPA 70E 120.6(7) guidelines. In the NFPA 70E 2024 edition, "point of work" is only mentioned twice, emphasizing the importance of establishing and maintaining an electrically safe work condition.

NFPA 70E 130.9(C)2 instructs personnel to visually identify de-energized, isolated and grounded conductors during work on overhead lines. Additionally, NFPA 70E 120.6(7) reinforces the test-before-touch principle, highlighting the use of portable voltmeters to verify work is performed only on de-energized conductors — this same principle, by context, also applies to PESDs and AVTs.

Michael Crepps from Fluke Corp.
Podcast
Trends in Electrical Safety: What Electricians Say

** 2 Consecutive Awards for Best Podcast, 2022 & 2023 APEX Awards of Publication Excellence

In this “Automation Chat" podcast from The Journal, Executive Editor Theresa Houck chats with Michael Crepps, Product Application Specialist at Fluke Corp., about the results of Fluke’s 4th Annual Electrical Safety Survey identifying trends in how electrical workers feel about workplace safety-related topics. Learn about the need for more training, development of a strong safety culture and knowledge sharing. Also discover some surprising findings.

And as always, get your family-friendly, silly Joke of the Day.

Listen on your favorite podcast app or on the web, or watch their conversation on YouTube.

Listen Now Watch Now

The inclusion of test point PESDs as part of the "point of work" concept demonstrates a commitment to advancing electrical safety, helping provide a safer work environment with accurate and confident absence of voltage testing.

When recognizing the significance of the "point of work" concept, it’s essential that PESDs are designed and installed in precise, yet practical locations within the panel or electrical system. This alignment with the "point of work" concept contributes to a safer working environment and reinforces the principles of electrical safety. By adhering to these guidelines, we can promote effective electrical safety practices and prioritize workers’ well-being.

Proper Placement of PESDs

Placement of PESDs, such as voltage presence indicators and high impedance protected test points, is pivotal for maximizing their effectiveness in electrical safety. Their precise positioning on electrical panels directly relates to the concept of the "point of work" and affects their ability to mitigate risks.

In the absence of a formal “point of work” definition by the Occupational Safety and Health Administration (OSHA), one OSHA letter of interpretation instructs the user that “point of work” should be as close as possible to where the LOTO devices are installed: “… locking and tagging out the circuit at the point of work (i.e., the panel to be worked on).”

In this context, OSHA also points out that if for some reason, locking and tagging a “panel” doesn’t fully de-energize the panel, additional measures, such as disconnecting upstream feeders, may be necessary. However, it’s safe to conclude that electrical panels can be considered the “point of work.”

This highlights the criticality of designing in PESDs and AVTs in the right locations that facilitate access and safer testing to achieve reliable verification of voltage status within the panel.

PESDs serve as an additional layer of protection, validating and communicating voltage conditions and supporting informed decision-making for workers engaged in electrical system maintenance. Proper placement aligns with the "point of work" concept so that electrical safety devices are strategically positioned to support maintenance activities and minimize risks associated with electrical hazards. Following manufacturer instructions during installation is vital to proper functioning and accurate results.

Safer Work Environment

The recent revisions to NFPA 70E have underscored the effectiveness of test point PESDs for absence of voltage testing. These devices — recognized as safety by design methods — play a critical role in electrical safety by providing a safe and efficient method for verifying the absence of voltage. Their permanent installation on electrical enclosures aligns with the "at each point of work" principle emphasized in the NFPA 70E 2024 Edition.

By adhering to the revised NFPA 70E requirements and using test point PESDs, qualified electricians can maintain compliance while promoting a safer work environment. The proper installation and use of these devices allow workers to test each phase conductor or circuit part precisely at the point of work, minimizing the risks associated with electrical hazards.

Staying informed about the latest developments in electrical safety, including the revisions to NFPA 70E, and embracing the benefits of devices such as PESDs are essential steps toward creating a safer work environment. Manufacturers can proactively address electrical safety concerns and protect their workforce from potential hazards.

Based in Davenport, Iowa, Grace Technologies is a Technology Partner in the Rockwell Automation PartnerNetwork™ program. The company designs and manufactures electrical safety products and predictive maintenance solutions, including GracePESDs®.

 

Like this article? Sign up for the digital magazine (4X/year) and e-newsletter from The Journal From Rockwell Automation and Our PartnerNetwork and get articles like this delivered right to your inbox.

 

 

The Journal From Rockwell Automation and Our PartnerNetwork™ is published by Endeavor Business Media.

Topics: The Journal
Recommended for You
Loading
  1. Chevron LeftChevron Left Rockwell Automation Home Chevron RightChevron Right
  2. Chevron LeftChevron Left Com... Chevron RightChevron Right
  3. Chevron LeftChevron Left News Chevron RightChevron Right
  4. Chevron LeftChevron Left The Journal Chevron RightChevron Right
  5. Chevron LeftChevron Left How to Use Point of Work Electrical Safety Devices Chevron RightChevron Right
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose