Scaling view

The
Scaling
view defines how motion is converted from controller units to user-defined engineering units. It includes settings for transmission, actuator characteristics, and axis travel limits.
The available parameters can be required or conditionally available based on the selected
Load Type
and
Mode
.
When a change affects dependent attributes, the system prompts you to recalculate values. Select
Calculate
to update dependent attributes.
Select
More Parameters
to open the Parameter List view.
Use the
Scaling
view to:
  • Define the relationship between controller units and user-defined units.
  • Configure transmission and actuator properties.
  • Specify scaling factors and reference units.
  • Set axis travel limits.
Scaling to convert Motion from controller units to user defined units
Parameter
Description
Load Type
Specifies the mechanical relationship between the motor and the load.
Available options include:
  • Direct Coupled Rotary
    One motor revolution corresponds directly to one load revolution.
  • Rotary Transmission
    Motion is transmitted through a mechanism requiring a defined ratio.
  • Linear Actuator
    Motor rotation is converted to linear motion.
Transmission
Parameter
Description
Ratio I:O
Defines the relationship between motor motion and load motion.
For example, a ratio of 2:1 indicates that two motor revolutions results in one load revolution.
This parameter is available when
Load Type
is set to
Rotary Transmission
or
Linear Actuator
.
Actuator
Parameter
Description
Type
Specifies the actuator mechanism used to convert motor motion to load motion.
Available options include:
  • <none>
    No actuator is applied.
  • Screw
    Converts rotary motion to linear motion using a lead screw.
  • Belt and Pulley
    Transmits rotary motion through a belt-driven system.
  • Chain and Sprocket
    Transmits rotary motion through a chain-driven system.
  • Rack and Pinion
    Converts rotary motion to linear motion using a gear rack.
Lead
Defines the linear travel distance per actuator revolution.
The value is specified together with a unit of measure.
Available options include:
  • Millimeter/Rev
  • Inch/Rev
Diameter
Specifies the diameter of the actuator component, along with the unit of measure.
The value is specified together with a unit of measure.
Available options include:
  • Millimeter
  • Inch
Scaling
Parameter
Description
Units
Specifies the unit type used for axis position. This unit defines the context used consistently across scaling and travel settings.
Available options include:
  • Position Unit
  • Motor Unit
  • Feedback Unit
Scaling
Specifies the position value expressed in
Units
that corresponds to the motion defined by
Per
.
Per
Defines the amount of motion required to achieve the
Scaling
value.
This value represents the denominator in the scaling relationship.
Together,
Scaling
and
Per
define the conversion between motion units and position values.
Motion Unit
Displays the motion unit used by the system (motor or feedback). This value is read-only and determined by the axis and feedback configuration on the
General
page.
This unit is used as the denominator basis in the
Scaling/Per
relationship.
Available options include:
  • Motor Rev
  • Load Rev
  • Feedback Rev
  • Motor Millimeter
  • Load Millimeter
  • Feedback Millimeter
  • Motor Rev/s
  • Motor m/s
Travel
Parameter
Description
Mode
Specifies how the axis position behaves during motion.
Available options include:
  • Unlimited
    The axis can move without defined position limits. This mode is typically used for continuous motion.
  • Limited
    The axis movement is constrained within defined minimum and maximum limits.
  • Cyclic
    The axis position repeats within a defined range, commonly used for rotary or repeating applications.
    Tip:
    When selecting
    Cyclic
    ,
    Soft Travel Limits
    is not available.
Range
Defines the motion range in position units.
This parameter is available when
Mode
is set to
Limited
.
Unwind
Defines how position accumulates relative to motor motion for cyclic axes.
Set the number of unwind cycles per motor revolutions.
The numerator units are position units. The denominator unit is fixed at
Motor Rev
.
This parameter is available when
Mode
is set to
Cyclic
.
Per
Specifies the number of reference units used with
Unwind
to define one complete cycle of motion.
Together,
Unwind
and
Per
define the wrap-around point and how position repeats for cyclic axes.
Soft Travel Limits
Enables or disables software-defined travel limits.
When enabled, the system monitors axis position and prevents motion beyond defined limits.
This parameter is not available when
Mode
is set to
Cyclic
.
Maximum Positive
Defines the maximum positive position limit used for software overtravel protection.
This value must be greater than
Maximum Negative
.
Maximum Negative
Defines the maximum negative position limit used for software overtravel protection.
This value must be less than
Maximum Positive
.
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.