Exceptions view

The
Exceptions
view defines how the drive responds to exception conditions that occur during axis operation. Exceptions represent conditions that can result in faults or alarms.
The associated drive determines which actions are available for each exception. When an exception occurs, the corresponding fault or alarm attributes of the axis are set.
Select
More Parameters
to open the Parameter List view.
IMPORTANT:
Changing exception action settings may require stopping or disabling the axis programmatically to protect personnel, equipment, and property.
Parameter
Description
Exception Condition
Lists the exception conditions supported by the drive.
Action
Specifies how the drive responds when the selected exception condition occurs.
Available actions depend on the drive and configuration.
  • Ignore
    No action is taken.
  • Alarm
    Generates an alarm without stopping the axis.
  • Fault Status Only
    Updates fault status without performing a stop action.
  • Stop Planner
    Stops the motion planner.
  • Disable
    Disables the axis.
  • Shutdown
    Initiates a shutdown of the drive.
  • Stop Drive
    Stops the drive.
  • Unsupported
    Indicates that the action is not supported.
Tip:
  • If a previously selected action is no longer supported due to a configuration change, most conditions default to
    Disable
    . In cases where
    Disable
    does not apply, the default is
    Fault Status Only
    . For example,
    Disable
    does not apply with a feedback-only type configuration.
  • The method used to stop an axis for a
    Stop Drive
    action depends on the specific exception condition and is determined by the drive. This behavior is not affected by the
    Disable (MSF) Stopping Action
    setting on the Actions page.