Add the module to Studio 5000 Logix Designer
Before you add your Historian module, make sure that the following prerequisites are met:
- The project file that contains the controller programming and configuration information (the.ACDfile) already exists in Logix Designer.
- Communication devices are added to theI/O Configurationfolder.
- Logic, tags, and communication path are defined.
- The controller is manually set to the remote run mode.
To add the module to Logix Designer
TIP:
The following steps may vary depending on your version of Logix Designer.
- Go toStart > Programs > Rockwell Software > Studio 5000.Studio 5000 Logix Designer appears.TIP:Alternatively, double-click the.ACDfile to open Logix Designer.
- On theFilemenu, clickOpen, and then browse for the Logix Designer project file.
- ClickOpen.The project is loaded.
- In the Controller Organizer, right-click theI/O Configurationfolder, and then clickNew Module.TheSelect Module Typedialog box appears.
- Select the Historian module that you want to add to the Logix Designer project.
- ClickCreate.
- TheNew Moduledialog box appears.
- In theName box, type the name of the module.The name will appear in the Controller Organizer.For information on naming conventions, see the Logix Designer user documentation.
- UnderEthernet Address, clickIP Address, and then type the IP address of the module.
- In theSlotlist, select the number of the slot in which the module is located.
- (optional) ClickChange, to configure the electronic keying, the connection type, and/or the revision number.TheModule Definitiondialog box appears.
- In theSerieslist, select the series of the Historian module.TIP:If Series C is missing from the list, go to the Product Compatibility and Download Center to download FactoryTalk Historian ME Client Tools version 7.00.00, and then install FactoryTalk Historian ME RSLogix 5000 Module Profile.
- In theRevisionlists, select the revision numbers of the firmware installed on the module.
- In theElectronic Keyinglist, select the desired option.For details, see the Logix Designer user documentation.
- In theConnectionlist, select the connection type, and then clickOK.TheNew Moduledialog box appears.
- ClickOK.The module appears in the Controller Organizer, underI/O Configuration.
- On theCommunicationsmenu, clickWho Active.TheWho Activedialog box appears.
- Select the controller to which you will download the Logix Designer project.
- ClickSet Project Pathto provide the path to the controller in the project.The path in the projects points now to the location of the controller.
- ClickDownloadto download the project to the controller.
- Verify the controller information.
- ClickDownload.The Logix Designer project is downloaded to the controller.
- ClickYes.
Provide Feedback