Device definition dialog box parameters (adapter)

Parameter
Description
Device type
Displays the device catalog number and type.
Change type
Changes the device type and revision.
Tip: This parameter is only available for
Studio 5000 Logix Designer
as the host software.
Name
Specifies the device name.
The name must be IEC_61131 compliant. If an invalid character is entered in this field or if the name exceeds 40 characters, the software ignores the character.
Description
Specifies the description for the device.
The description must be within 512 characters. If the description exceeds the maximum length, the software ignores any extra characters.
EtherNet address
Specifies the IP configuration for the device. Possible options include:
  • Private network
    . Select the value from 1 to 254.
  • IP address
    . Enter a unique IP address to identify each node on the IP network.
  • Host name
    . Enter a fully qualified domain name, such as device.yourcompany.com.
Enable Network Address Translation (NAT)
Enables safety communication to a device addressed through NAT.
Actual device address
Specifies the device's IP address on the Private Network of the NAT. It is the same IP address found in the
Internet Protocol
view.
This parameter is available when the
Enable Network Address Translation (NAT)
checkbox is selected.
Slot
Specify the slot number where the device resides. Only slots between 1 and the maximum number of I/O devices are valid depending on the platform.
When the device is created, the slot number defaults to the first available slot position.
When the controller is changed to one supporting a smaller maximum I/O count, the current slot value may no longer be valid.
Revision
Specifies the major and minor revisions of the device. The valid range for minor revision is from 1 through 255.
Electronic keying
Defines the electronic keying used for the device. Electronic keying compares the device defined in the project to the installed device. If keying fails, a fault occurs.
Valid values include:
  • Exact Match
  • Compatible Module
  • Disable Keying
For detailed information on Electronic keying, see Electronic Keying in Logix5000 Control Systems Application Technique, publication LOGIX-AT001.
Connection
Sets the Connection Type or the Communication Format.
Network mode
Specifies the network mode as
Device Level Ring (DLR)
or
Parallel Redundancy Protocol (PRP)
.
Chassis size
Sets the chassis size of the rack that contains the adapter bridge device. Only the valid chassis sizes are displayed.
The chassis size cannot be set to a size that is less than the last device in the chassis.
This parameter is only available when the device is an adapter in the topology.
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.
Normal